00195376-05_SM_D1_D1i_D2_D2i_EN.pdf - 第186页

Service Work Cutter 4.8.3 Replacing the Control Unit [03006411] 186 Service Manual SIPLACE D1/D1i/D2/D2i Installation 4.8.3 4 . 8 . 3 R e p la c in g t h e C o n t r o l U n it [ 0 3 0 0 6 4 1 1 ] Replacing the Cont rol …

100%1 / 280
Service Work
4.8.2 Replacing the Articulated Joint on the Short-Stroke Cylinder [03000518-xx] Cutter
Service Manual SIPLACE D1/D1i/D2/D2i 185
Legend
1. Articulated joint on the short-stroke cylinder
2. Fastening screw on the moveable blade (under the
cover flap)
Loosen the screw (2) holding the moveable blade.
CAUTION! Risk of injury!
There is a risk of injuring yourself on the cutting edges of
the blades.
Use a permanent marker to mark the exact installa-
tion position of the proximity switch (1) on the short-
stroke cylinder. Mark the hoses.
Loosen the screws fastening the two inductive prox-
imity switches (1) to the short-stroke cylinder.
Remove the compressed air connections (2) on the
short-stroke cylinder.
Remove the two screws (3) holding the short-stroke
cylinder.
Pull the short-stroke cylinder (4) and the articulated
joint screwed into it (5) out of the cutter set (6).
Unscrew the articulated joint (1) from the cylinder.
NOTICE! The threaded pin is secured with Loc-
tite no 241. You will need somewhat more strength than
usual to loosen it.
Apply a small amount of Loctite no. 241 to the thread
(2) of the new joint.
Screw the articulated joint (1) into the short-stroke
cylinder.
Turn the articulated joint into the installation position
(3). Once the cylinder is installed, the slot in the
moveable blade prevents the articulated joint from
turning.
1
2
1
6
5
4
3
2
1
4
3
2
Service Work
Cutter 4.8.3 Replacing the Control Unit [03006411]
186 Service Manual SIPLACE D1/D1i/D2/D2i
Installation
4.8.3
4.8.3 Replacing the Control Unit [03006411]
Replacing the Control Unit [03006411]
Removal/Installation
Install the proximity switch (1) precisely in the position
you marked with the permanent marker.
Insert the prepared cylinder into the cutter, with the
correct rotary position of the articulated joint (2) i.e.
the joint axes must be vertical.
Fasten the cylinder in this position, with the 2 screws
provided (3).
Connect the compressed air hoses to the cylinder in
the correct allocation.
Check the gap between the leading edge of the tape
deflector and the "empty-tape baffle, inside".
Check the switching points of the proximity switches.
1
3
2
NOTICE
If the tapes are not cut correctly, even though the switching points have been set properly and
the short-stroke cylinder has been exchanged - complete with the one-way restrictor - the cause
of the problem may be:
Incorrect compressed air level
Leaking compressed air connection or Y-socket union
Legend
1. Control unit under the cover
Dismantle the waste slide.
Remove the cover (1) from the control unit.
1
Service Work
4.8.4 Replacing the Solenoid Valves [03000630] Cutter
Service Manual SIPLACE D1/D1i/D2/D2i 187
4.8.4
4.8.4 Replacing the Solenoid Valves [03000630]
Replacing the Solenoid Valves [03000630]
Overview
Mark the allocation of all press-fit connections and
disconnect all press-fit connections (2) from the con-
trol unit.
Remove the cable ties and the connection cable fix-
tures.
Carefully pull the control unit (3) off its mount (4).
Carefully insert the new control unit onto the mount,
in the correct rotary position and location, until it locks
into place.
Restore all plug-and socket connections in the cor-
rect allocation.
Run the connection cables and fasten with cable ties
(strain relief).
Check the jumper setting according to the label on
the control unit and adjust, if necessary.
Replace the control unit cover.
Fit the waste slide.
1
4
3
2
1. Position of the solenoid valves
1