4 Operation
4.1 Settings in SIPLACE Pro
User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 45
Defining an Auto Cavity dipping plate (only for LDU 2 X with Auto Cavity option)
In the Tools Tree View, select the dipping plate to be defined(1).
In the Object Properties area, select Adjustable Cavity Depth from the Plate Type
menu(2).
Enter the appropriate coordinates and the cavity depth range in the corresponding fields(1).
Left X / Left Y: Lower left corner of the cavity
Right X / Right Y: Upper right corner of the cavity
Minimum / Maximum Cavity Depth: Travel range of the cavity plate
The coordinates and the depth range of the cavity are displayed in the display area(2).
4 Operation
4.1 Settings in SIPLACE Pro
46 User Manual SIPLACE Linear Dipping Unit 2 X 05/2020
4.1.3 Assigning a dipping plate and a flux to the LDU
On one placement machine, several LDU units can be used. Each LDU can be fitted with another
dipping plate type and filled with another flux, suitable to the dipping requirements of the compon-
ents. For this purpose, the appropriate dipping plate and flux material must be assigned to every
LDU set up.
Assigning a dipping plate to the LDU 2 X
In SIPLACE Pro, click on the tab of the Setup(1).
Click on the Tables on setup tab(2) in the Object Properties view.
In the Properties tree view, click on the Dipping Divisions folder of the desired LDU 2 X(3).
Click on the blank field in the Dipping Plate Type column of the Dipping Division Paramet-
ers area(4).
A Select button with three points is displayed.
Click on the Select button(5).
A dialog window is displayed.
Click on the desired dipping plate in the tree view(6).
Click OK(7).
4 Operation
4.1 Settings in SIPLACE Pro
User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 47
Assigning a flux to the LDU 2 X
Click on the blank field in the Processing Material column of the Dipping Division Paramet-
ers area(1).
A Select button with three points is displayed.
Click on the Select button(2).
A dialog window is displayed.
Click on the desired flux material in the tree view(3).
Click OK(4).
The dipping plate and the flux assigned to the LDU 2 X are now displayed in the Dipping Division
Parameters table in the Feeders area(1) and on the LDU 2 X symbol in the display area(2).