00193796-08.pdf - 第16页
Installation Manual Station Software Version 505.04 16 of 156 3.2.3 Station computer 3.2.3.1 Station computer HF, HF/3 Name Simicro CPU076 CPU / clock frequency PIII / 866 MHz or 1,26 MHz RAM memory 192 MB Hard disk 6 GB…

Installation Manual, Station Software Version 505.04 Edition 07/2006
15 of 156
3.2.2 Network configuration
HF, HF/3 machine
SIPLACE Pro
Station computer Machine controller
10Base-T
GEM host
10Base-T
100Base-T
Private netw ork betw een
station computer and
machine controller
SIPLACE LAN
Fig. 3-4: Network connections between the machine, SIPLACE Pro and GEM host (optional) Example: (SIPLACE HF and
HF/3)
A separate private network (100 Mbit) is set up between the station computer and the machine
controller via a subnet mask.
Fixed IP addresses for the station computer and the machine controller can thus be assigned for all
SIPLACE machines. These IP addresses are not known outside the private network, for instance in
the SIPLACE LAN.
These IP addresses need not be further configured by the operator while the station software is
being installed.
IP address, station computer
192.168.255.249
IP address, machine controller
192.168.255.250
Subnet mask, station computer/machine controller
255.255.255.248
IP address range, SIPLACE LAN
172.22.xxx.xxx
Subnet mask, SIPLACE LAN
255.255.0.0
Table 3-1: Network configuration

Installation Manual Station Software Version 505.04
16 of 156
3.2.3 Station computer
3.2.3.1 Station computer HF, HF/3
Name
Simicro CPU076
CPU / clock frequency
PIII / 866 MHz or 1,26 MHz
RAM memory
192 MB
Hard disk
6 GB
CD-ROM drive
Yes
Floppy drive
3.5", 1.44 MB
Serial interfaces
2
Network
1 x 10/100Base-T
2 x 10Base-T
6-port hub
Table 3-2: Station computer hardware
3.2.3.2 Station computer S-25 HM, S-27 HM
Name
SCENIC N 300
CPU / clock frequency
PIV / 2.4 GHz
RAM memory
256 MB
Hard disk
40 GB
CD-ROM drive
Yes
Floppy drive
3.5", 1.44 MB
Serial interfaces
2
Network
1 x 10/100Base-T
1 x 10Base-T
Table 3-3: Station computer hardware
3.2.3.3 Station computer HS-50, HS-50+, HS-60
Name
SCENIC P 300
CPU / clock frequency
PIV / 2.6 GHz
RAM memory
256 MB
Hard disk
40 GB
CD-ROM drive
Yes
Floppy drive
3.5", 1.44 MB
Serial interfaces
2
Network
1 x 10/100Base-T
2 x 10Base-T
6-port hub
Table 3-4: Station computer hardware

Installation Manual, Station Software Version 505.04 Edition 07/2006
17 of 156
3.2.4 Machine controller
3.2.4.1 Machine controller HF, HF/3
Name
Simicro CPU076
CPU / clock frequency
PIII / 566 MHz
RAM memory
64 MB
Hard disk
6 GB
CD-ROM drive
Yes
Floppy drive
3.5", 1.44 MB
Network
1 x 10/100Base-T
Table 3-5: Machine controller hardware
3.2.4.2 Machine controller S-25 HM, S-27 HM, HS-50, HS-50+, HS-60
Name
Sicomp AMS - M54
CPU / clock frequency
PI / 233 MHz
RAM memory
32 MB
Hard disk
504MB
CD-ROM drive
No
Floppy drive
3.5", 1.44 MB
Network
1 x 10/100Base-T
Table 3-6: Machine controller hardware