00193796-08.pdf - 第55页
Installation Manual, Station Software Version 505.04 Edition 07/2006 55 of 156 4.3.4 Troubleshooting → If the installation program terminates prematur ely due to an error, remove the floppy from the drive and switch the …
Installation Manual Station Software Version 505.04
54 of 156
Example of hosts:
#******************************************************************************
#
# File : C:\ETC\HOSTS
#
# Author/Date : T. Noetzold 16-Aug-1995
#
# Abstract : Konfigurationsdatei fuer TCP/IP
#
# Inskript: : AUT 5 BSM 13 $Author:: ake/mme $
# $Date:: 10 Sep 1996 23:41:16$
# $Revision:: 3.0 $
#
# Usage : Durch TCP/IP-Software
#
#******************************************************************************
# Copyright (C) 1992-1996 by Siemens AG. All rights reserved
#******************************************************************************
#
# Internet Official List Of Aliases # Comment
# Address Host Name
#
127.255 loop
172.22.231.84 local localhost # my IP address!
172.22.231.82 autsr traceserver # station computer
220.9.200.1 autgem # gem computer
# --- end of host file ---
SD EA 1 has a globally unique Class B internet address.
Since the machine controller and the station computer have a separate subnet, the machine
controller only has one unique internet address.
This official Class B internet address is 192.168.255.250. The address of the station computer on
this subnet is 192.168.255.249. We will make the correct settings for you. (This information is also
contained in the machine documents).
Should you have any queries, contact our Service department.
→ If 'S' is selected, the file '\ETC\SERVICES' appears in the DOS editor.
→ If 'X' is selected, the menu is exited and the DOS prompt appears.
→ Remove the floppy disk from the drive.
→ To start the SIPLACE system, switch the machine off and then on again.

Installation Manual, Station Software Version 505.04 Edition 07/2006
55 of 156
4.3.4 Troubleshooting
→ If the installation program terminates prematurely due to an error, remove the floppy from the
drive and switch the machine off.
→ Insert floppy #1 into the drive and switch the machine on again.
→ Try installing the machine controller operating system again.
Note:
If the software can still not be installed on the second attempt,
contact your Service center.

Installation Manual Station Software Version 505.04
56 of 156
4.4 Installing the machine controller M54 (HS-50, HS-50+, HS-60, S-25
HM and S-27 HM)
4.4.1 BIOS Setup
When taking the M54 into service for the first time, the BIOS parameters must be set for the relevant
machine. A configuration file is used in order to automatically modify the data. The program starts
automatically after booting and does not require user input. This resets the default settings of the
BIOS. Thus the configuration remains available even in the event of faults. After successful
installation, the power supply of the control unit should be switched off and then back on again. The
only settings the user will need to make manually in the Setup are the date and time. The automatic
Setup should be called before partitioning or formatting the hard disk.
The floppy disks required for this are created using the file HS50BIOS.exe using the same
procedure as the operating system disks (for more information, see section
4.3.3.1). In order to be
able to check the settings that have been made, the following section describes the procedure for a
manual Setup and lists the values.
NOTE: M54 machine controller with a 30-GB hard disk
Proceed as follows to set up the 30-GB hard disk:
- Call the BIOS setup by pressing F2 immediately the machine is switched on.
- Call up the "AT Hard Disk" setup page.
- Click the "Auto all Drives" button.
The M54 now determines the parameters for the connected hard drive. The following entries are
shown for the 30-GB drive in the "Primary IDE Controller" field:
Master: [√ ] USR1 3648 255 63 None ??? ??? LBA [ ] [ ] [ ]
- Close the BIOS setup with "Exit" and "Save".