Installation Manual, Station Software Version 505.04 Edition 07/2006 57 of 156 Information: The original partitions are displayed correctly , but to not function correctly. Simply reformatting the disk does not solv e th…

100%1 / 156
Installation Manual Station Software Version 505.04
56 of 156
4.4 Installing the machine controller M54 (HS-50, HS-50+, HS-60, S-25
HM and S-27 HM)
4.4.1 BIOS Setup
When taking the M54 into service for the first time, the BIOS parameters must be set for the relevant
machine. A configuration file is used in order to automatically modify the data. The program starts
automatically after booting and does not require user input. This resets the default settings of the
BIOS. Thus the configuration remains available even in the event of faults. After successful
installation, the power supply of the control unit should be switched off and then back on again. The
only settings the user will need to make manually in the Setup are the date and time. The automatic
Setup should be called before partitioning or formatting the hard disk.
The floppy disks required for this are created using the file HS50BIOS.exe using the same
procedure as the operating system disks (for more information, see section
4.3.3.1). In order to be
able to check the settings that have been made, the following section describes the procedure for a
manual Setup and lists the values.
NOTE: M54 machine controller with a 30-GB hard disk
Proceed as follows to set up the 30-GB hard disk:
- Call the BIOS setup by pressing F2 immediately the machine is switched on.
- Call up the "AT Hard Disk" setup page.
- Click the "Auto all Drives" button.
The M54 now determines the parameters for the connected hard drive. The following entries are
shown for the 30-GB drive in the "Primary IDE Controller" field:
Master: [ ] USR1 3648 255 63 None ??? ??? LBA [ ] [ ] [ ]
- Close the BIOS setup with "Exit" and "Save".
Installation Manual, Station Software Version 505.04 Edition 07/2006
57 of 156
Information: The original partitions are displayed correctly, but to not function correctly.
Simply reformatting the disk does not solve the problem.
- Create with FDISK follwowing partitions:
Partition Status Typ Mbyte
C:1 A PRI DOS 50
2 EXT DOS 450
- Restart the computer (Press simultaneously Ctrl + Alt + Del).
- Now the 505 software can be installed in the normal manner for a new hard disk.
Note:
You find more details concerning the BIOS setting, operating system etc. in our Technical
Information that are online available via the SIEMENS DMS (
www.siplace.com ).
Installation Manual Station Software Version 505.04
58 of 156
4.4.1.1 Starting the BIOS Setup
To start the BIOS setup, wait for the following message to appear on the screen after the system
has been booted and then press the <F2> key.
PowerBIOS Version 1.00
Copyright(C) 1984-1995, Award Software, Inc.
12/06/96 - Intel - 82430HX
AMS-M54 V 1.00
┌────────────────────────────────────────────────────────────────────────┐
CPU Type...............................................Pentium xxx MHz
Math CoProcessor..............................................Internal
.
.
.
.
.
.
.
.
└────────────────────────────────────────────────────────────────────────┘
Press F2 to enter setup