00195346-0302_SM_WPC4_EN.pdf - 第12页
Operational Safety Safety Instructions Correct U sage 12 Ser vice Manual SIPLACE WPC4 2.2.5 Correct Usage The product may only be used for the ap plication described in the catalogue s and technical specifications i.e. f…

Operational Safety
Safety Instructions for the Compressed Air Supply Safety Instructions
Service Manual SIPLACE WPC4
11
2.2.2.1 Safety Instructions for Work on the Cutting Device
2.2.3 Safety Instructions for the Compressed Air Supply
2.2.4 Safety Instructions for Working with Strong Magnetic Fields
WARNING: Risk of injury when working near the cutter.
If you wish to work on the tape cutter, disconnect the machine from the mains supply and
compressed air supply.
X Wait until the operating pressure has dropped to 0 MPa.
X Always secure the machine against unauthorized reactivation.
X Wear appropriately thick protective gloves when working near the blades/the tape deflector!
X There is a high risk of injury from stationary blades and moveable blades and from the tape
deflector of the cutter, even when the machine has been turned off!
X Never reach into the pneumatic cutter from below or into the empty-tape duct from above, not
even to resolve a problem (e.g. when tape is jammed).
CAUTION: Risk of injury when performing service work on the cutter.
Never support the cutter on your body, e.g., on your knees or thighs. Do not place your feet
under the cutter.
X Wear robust protective gloves.
X When removing the cutter, grasp it only on the left and right, on the outside.
X Make certain that no one can injury themselves on the cutter, after it has been dismantled!
CAUTION: Risk of injury from compressed air!
Risk of injury when disconnecting the compressed air lines.
X NEVER detach compressed air lines while they are still pressurized.
ATTENTION: Prolonged interruptions to the compressed air supply could cause damage.
When the machine is switched on, do not use the stop valve to interrupt the compressed air
supply for more than 30 minutes.
X If you need to shut off the pneumatic system for longer in order to carry out preventive
maintenance or servicing work, you must switch the placement system off at the main switch
and disconnect it from the power supply.
WARNING: STRONG MAGNETIC FIELDS
Fatal hazard: persons with active implants (e.g. pacemakers, defibrillators, insulin pumps etc.)
are at risk from strong permanent magnetic fields inside the machine.
X Persons are risk should avoid the immediate vicinity of the machine.
CAUTION: DANGER OF CRUSHING
Danger of crushing for persons with passive metal implants (e.g. plates, screws).
X Do not reach into the machine or bend towards it when the protective covers are open.
X Do not bring any metal objects into the area.

Operational Safety
Safety Instructions Correct Usage
12 Service Manual SIPLACE WPC4
2.2.5 Correct Usage
The product may only be used for the application described in the catalogues and technical
specifications i.e. for placement of SMD components and only in connection with the third party devices
and components recommended or approved by ASM AS.
Any other use is deemed to be incorrect and not as prescribed.
In the case of incorrect usage, ASM AS will not assume liability for any damage which occurs and will
not guarantee the correct and proper function of product components.
Prescribed or correct usage includes the observance of all the instructions in the user manual.
The proper and safe operation of the product requires correct transportation, storage, installation and
assembly, plus careful, accurate utilization and servicing.
2.2.6 Incorrect Usage
Failure to use the product as prescribed can result in both danger to life and limb and material damage.
Incorrect usage is therefore prohibited. In the case of incorrect usage, ASM AS will not assume liability
for any damage which occurs and will not guarantee the correct and proper function of product
components.
Failure to use the product as prescribed includes, for example:
The use on other machines than those machine types officially approved by ASM AS for this
product.
The use of the product in a working environment which deviates from that described in this manual.
The use of the placement machine with the installed product by unqualified personnel.
ATTENTION: STRONG MAGNETIC FIELDS
X Do not place magnetic data carriers, check or credit cards in the vicinity of permanent
magnets - there is a risk that the powerful magnetic fields could corrupt data on data media.
X Keep wristwatches away from the permanent magnets as these could be irreparably
damaged by the magnets.
DANGER:
X Never place metal objects made of iron, steel or nickel in the vicinity of permanent magnets.
The powerful forces of attraction could cause fingers to be trapped and crushed.

Operational Safety
Warning labels Safety Instructions
Service Manual SIPLACE WPC4
13
2.2.7 Warning labels
2.2.7.1 Laser note at the 1D PCB barcode reader
2-1: Warning labels at the rear side of the 1D PCB barcode reader
The laser note is located at the rear side of the 1D
PCB barcode reader.
LASER RADIATION!
Do not look into beam
Laser class 2
Item No. 03009347-01