Replacing Spare Parts Drive Unit – Feed Axis Replacing t he Feed Axis Toothe d Belt [03047690 -xx] 26 Ser vice Manual SIPLACE WPC4 3.4.4 Replacing the Feed Axis T oothed Belt [03047690-xx] Spare part  Toothed belt 16T5/…

100%1 / 108
Replacing Spare Parts
Replacing the Drive Toothed Belt [03047689-xx] Drive Unit Feed Axis
Service Manual SIPLACE WPC4
25
3.4.3 Replacing the Drive Toothed Belt [03047689-xx]
Spare part
Drive toothed belt 16T5/330 [03047689-01]
Overview
1. Feed axis motor, compl. [03047364-01]
2. Tensioning screw
3. 2 x motor support fastening screws
4. Toothed belt for the drive
5. Deflection pulley
Removal/Installation
X Loosen the two motor support fastening
screws (3) sealed with locking varnish.
X Loosen (do not remove) the tensioning screw
(2) on the tensioning device. This relaxes the
drive toothed belt (4).
X Loosen and remove the 2 fastening screws (3)
and then remove the old drive toothed belt (4).
X Move the motor and motor support (1) into the
installation position and run the drive toothed
belt (4) around the motor pinion (2) and around
the deflection pulley (5). Make sure that the
drive toothed belt (4) is not buckled or
damaged.
X Tension (pretension) the drive toothed belt at
the slot provided, with the help of the motor
support.
Replacing Spare Parts
Drive Unit – Feed Axis Replacing the Feed Axis Toothed Belt [03047690-xx]
26 Service Manual SIPLACE WPC4
3.4.4 Replacing the Feed Axis Toothed Belt [03047690-xx]
Spare part
Toothed belt 16T5/2120E [03047690-01]
Preparations
X Move the tower into the refill position.
X Remove all waffle pack tray carriers (WPTCs) from the tower.
X Move the tower downwards.
SITEST =>
Functions
menu=>
Conveyor position
button
X Undock the WPC4 from the SIPLACE machine and move it to a suitable position for service work.
X Switch the WPC4 off at the main switch.
X Unplug from the power supply and secure the WPC4 to prevent unauthorized reactivation.
X Loosely fix the motor support and drive motor
into the installation position, with the 2
fastening screws (3).
X Set the final belt tension. To do this, tension
the drive toothed belt at the tensioning device,
with the help of the tensioning screw (2). This
moves the motor support accordingly in the
slots.
Setting value: Set the belt tension to
260 Hz. +/- 10 Hz.
X Tighten the 2 fastening screws (2) on the
motor support, check the belt tension and
adjust where necessary.
X Seal the 2 fastening screws (3) with locking
varnish.
Replacing Spare Parts
Replacing the Feed Axis Toothed Belt [03047690-xx] Drive Unit Feed Axis
Service Manual SIPLACE WPC4
27
Removal/installation
X Move the catch feed axis with the toothed belt
into a suitable position for service work (at the
front, in the transfer area).
X Loosen the two fastening screws (1) sealed
with locking varnish, at the tensioning device
with the deflection pulley (3).
X Loosen (do not remove) the tensioning
screw (2) - sealed with locking varnish - on the
tensioning device. This relaxes the toothed
belt.
X Loosen the 4 fastening screws (4) on the catch
unit (5). The two ends of the toothed belt are
fixed to this.
X Carefully remove the catch unit (5). This
toothed belt is now loose.
X Note how the toothed belt is run, so that you
can fit it again correctly later on. Pull the
toothed belt over the two deflection pulleys
(back and front) and out of the WPC4.
X Remove the tensioning device and deflection
pulley (3), so that you can feed in the new
toothed belt more easily. To do this, loosen the
two fastening screws (1).
X Insert the toothed belt into the WPC4 at the
transfer position and run it from the tensioning
device (1) to the deflection pulley (4). The
toothed belt should exit below the bottom
deflection pulley (3).
X Place the end of the toothed belt around the
back deflection pulley (3) and insert into the
clamping unit (5).
X Place the other end of the toothed belt around
the deflection pulley of the tensioning unit (2)
and run as far as the clamping unit (5).
X Fit the tensioning device with deflection pulley
and fix into place with the two fastening
screws.