SITEST for WPC4 SITEST Axes Positioning Data 92 Ser vice Manual SIPLACE WPC4 5.7.6 Positioning Dat a Speed [0.01 m/s]: Sh ows the current speed of the selected axis. Acceleration [0.1 m/s²]: Shows the current acceler…

SITEST for WPC4
Standard Values SITEST Axes
Service Manual SIPLACE WPC4
91
5.7.5 Standard Values
Default speed [0.01 m/s]: Shows the maximum speed of the selected axis.
Default acceleration [0.1 m/s²]: Shows the maximum acceleration with which the feed axis moves
out of the tower.
Default removal speed [0.01 m/s]:Shows the maximum acceleration with which the feed axis
moves into the tower.
OK : Closes the dialog box.
NOTE:
The following parameters are for information purposes only and can not be edited.

SITEST for WPC4
SITEST Axes Positioning Data
92 Service Manual SIPLACE WPC4
5.7.6 Positioning Data
Speed [0.01 m/s]: Shows the current speed of the selected axis.
Acceleration [0.1 m/s²]: Shows the current acceleration of the selected axis.
Accept: Confirms the entry and closes the dialog box.
Cancel: Closes the dialog box and rejects any changes made.
Edit...: Opens a dialog box in which you can enter the required speed and acceleration.
Setting values
X Mark the parameter which you want to change.
X Select
Edit..
.

SITEST for WPC4
Positioning Data SITEST Axes
Service Manual SIPLACE WPC4
93
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.
ATTENTION:
WPC machine data is saved directly in the WPC when a change is made.
Back up the current status, so that is can be restored.