00195346-0302_SM_WPC4_EN.pdf - 第74页
Calibration and Settings Other Functions Calibrating Refe rence Fiducials 74 Ser vice Manual SIPLACE WPC4

Calibration and Settings
Calibrating Reference Fiducials Other Functions
Service Manual SIPLACE WPC4
73
4.4.5 Calibrating Reference Fiducials
The WPC4 has two reference fiducials for determining the exact position in the docked SIPLACE
machine. These reference fiducials are automatically approached and measured after docking. If these
reference fiducials are not found, you will need to calibrate them.
X Open the SITEST main view and select the function=>
SITEST Functions
.
X In the input area
Calibrate pickup position
select
Calibration
.
X Follow the instructions as you are guided through the menu. See also SITEST.
NOTE: Calibration required after conversion
X After converting from the changeover table to the WPC4, perform calibration of the reference
fiducial.
Calibration and Settings
Other Functions Calibrating Reference Fiducials
74 Service Manual SIPLACE WPC4

SITEST for WPC4
General
Service Manual SIPLACE WPC4
75
5SITEST for WPC4
5.1 General
With the help of the functions in the SITEST test program, you can set up and calibrate SIPLACE
placement machines. This manual explains the individual SITEST dialog boxes for the WPC4. This
documentation refers to SITEST version 603.01.
The data in the dialog boxes, such as times, travel ranges, lengths or folders are only examples and are
not intended for use as references.
The square brackets contain measurements such as [mm] for millimeters, [s] for seconds etc. If there is
a conversion factor in front of this, the value in the square brackets must be multiplied by this figure.
Examples:
90 [0.1 mm] = 9 mm
3000 [0.01m/s²] = 30 m/s².
The "Help" button has the same function in all dialog boxes and will not be included in the following
explanations. This "Help" button opens the online help and shows the help text for the dialog box
currently open.
5.2 Safety Instructions
5.3 Opening the SITEST Interface
The SITEST user interface can be opened as follows from the main view of the station computer user
interface:
Select the icon from the toolbar
or
Open the View menu and select Start SITEST
or
Press the F11 key and acknowledge the dialog box shown with
Yes
.
DANGER: The SITEST program may only be operated by trained SIPLACE
staff or customer personnel.
X Always observe the general safety instructions in the operating manuals of the respective
SIPLACE machines and the WPC4.
NOTE: The SITEST program can not be opened in the "Operator" access level.