5TROUBLESHOOTING_.pdf - 第113页

3.3 . 1 Reset Procedure from Component Recognition Error ( 1 L 90 — ) Order of Error Codes ( Display C ) • ( Display A ) _ ( Display B ) • ( Cause ) ■ ( Remedy ) ( Display B ) " EDGE DATA 1 FORM " EXCEEDS THE R…

100%1 / 161
3.3
.
1
Reset
Procedure
from
Component
Recognition
Error
(
1
L
90
)
Order
of
Error
Codes
(
Display
C
)
(
Display
A
)
(
Display
B
)
(
Cause
)
(
Remedy
)
(
Display
C
)
1
L
90
B
039
(
Display
B
)
LEAD
1
DIRECTION
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
A
)
Component
Library
Data
Error
1
L
90
(
Display
C
)
1
L
90
B
040
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
LEAD
2
DIRECTION
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
90
B
041
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
LEAD
3
DIRECTION
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Cause
1
)
The
lead
directions
of
the
selected
component
have
exceeded
the
parameters
specified
in
the
"
DIRECTION
"
text
boxes
of
the
label
"
LEAD
DATA
"
in
the
component
library
data
.
(
Remedy
1
)
Check
the
selected
component
and
the
parameters
set
in
the
"
DIRECTION
"
text
boxes
of
the
label
"
LEAD
DATA
"
in
the
component
library
data
.
If
wrong
parameters
are
set
in
the
component
library
data
,
correct
them
.
(
Display
C
)
1
L
90
B
042
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
LEAD
1
POSITION
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
90
B
043
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
LEAD
2
POSITION
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
90
B
044
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
LEAD
3
POSITION
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Cause
1
)
The
lead
positions
of
the
selected
component
have
exceeded
the
parameters
specified
in
the
POSITION
"
text
boxes
of
the
label
"
LEAD
DATA
"
in
the
component
library
data
.
(
Remedy
1
)
Check
the
selected
component
and
the
parameters
set
in
the
"
POSITION
"
text
boxes
of
the
label
"
LEAD
DATA
'
1
in
the
component
library
data
.
If
wrong
parameters
are
set
in
the
component
library
data
,
correct
them
.
(
Display
C
)
1
L
90
B
045
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
LEAD
WIDTH
TOLERANCE
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Cause
1
)
The
lead
width
tolerance
of
the
selected
component
has
exceeded
the
parameter
specified
in
the
"
LEAD
WIDTH
TOLERANCE
"
text
box
in
the
component
library
data
.
(
Remedy
1
)
Check
the
selected
component
and
the
parameter
set
in
the
"
LEAD
WIDTH
TOLERANCE
"
text
box
in
the
component
library
data
.
If
a
wrong
parameter
is
set
in
the
component
library
data
,
correct
it
.
9910
-
001
ACP
01
EERW
3
-
21
3
-
21
3.3
.
1
Reset
Procedure
from
Component
Recognition
Error
(
1
L
90
)
Order
of
Error
Codes
(
Display
C
)
(
Display
A
)
_
(
Display
B
)
(
Cause
)
(
Remedy
)
(
Display
B
)
"
EDGE
DATA
1
FORM
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
A
)
Component
Library
Data
Error
(
Display
C
)
1
L
904046
1
L
90
(
Display
B
)
"
EDGE
DATA
2
FORM
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
904047
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
EDGE
DATA
3
FORM
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
A
)
Component
Library
Data
Error
(
Display
C
)
1
L
904048
(
Display
B
)
"
EDGE
DATA
4
FORM
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
904049
(
Display
A
)
Component
Library
Data
Error
(
Cause
1
)
Wrong
parameters
are
set
in
the
"
FORM
text
boxes
of
the
label
"
EDGE
DATA
"
in
the
component
library
data
for
the
selected
component
.
(
Remedy
1
)
Check
the
selected
component
and
the
parameters
set
in
the
"
FORM
"
text
boxes
of
the
label
"
EDGE
DATA
in
the
component
library
data
.
If
wrong
parameters
are
set
in
the
component
library
data
,
correct
them
.
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
EDGE
DATA
1
DETECT
X
POS
.
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
904050
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
EDGE
DATA
1
DETECT
Y
POS
.
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
904051
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
EDGE
DATA
2
DETECT
X
POS
.
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
904052
(
Display
B
)
"
EDGE
DATA
2
DETECT
Y
POS
.
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
A
)
Component
Library
Data
Error
(
Display
C
)
1
L
904053
(
Display
B
)
"
EDGE
DATA
3
DETECT
X
POS
.
"
EXCEEDS
THE
RANGE
OF
SETTING
,
(
Display
C
)
1
L
904054
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
EDGE
DATA
3
DETECT
Y
POS
.
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
904055
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
EDGE
DATA
4
DETECT
X
POS
.
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
904056
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
EDGE
DATA
4
DETECT
Y
POS
.
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
904057
(
Display
A
)
Component
Library
Data
Error
(
Cause
1
)
The
edge
detection
positions
X
and
Y
of
the
selected
component
have
exceeded
the
parameters
specified
in
the
"
DETECT
X
POS
.
"
and
"
DETECT
Y
POS
.
"
text
boxes
of
the
label
"
EDGE
DATA
"
in
the
component
library
data
.
(
Remedy
1
)
Check
the
selected
component
and
the
parameters
set
in
the
"
DETECT
X
POS
.
and
"
DETECT
Y
POS
.
"
text
boxes
of
the
label
"
EDGE
DATA
"
in
the
component
library
data
.
If
wrong
parameters
are
set
in
the
component
library
data
,
correct
them
.
3
-
22
9910
-
001
ACP
01
EERW
3
-
22
3.3
.
1
Reset
Procedure
from
Component
Recognition
Error
(
1
L
90
)
Order
of
Error
Codes
(
Display
C
)
(
Display
A
)
(
Display
B
)
(
Cause
)
(
Remedy
)
(
Display
C
)
1
L
905058
1
L
90
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
LEAD
FORM
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Cause
1
)
A
wrong
parameter
is
set
in
the
"
LEAD
FORM
"
text
box
in
the
component
library
data
for
the
selected
component
.
(
Remedy
1
)
Check
the
selected
component
and
the
parameter
set
in
the
"
LEAD
FORM
"
text
box
in
the
component
libraiy
data
.
If
a
wrong
parameter
is
set
in
the
component
library
data
correct
it
.
(
Display
C
)
1
L
905059
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
NUMBER
OF
LEAD
1
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
905060
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
NUMBER
OF
LEAD
2
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
905061
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
NUMBER
OF
LEAD
3
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Display
C
)
1
L
905062
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
NUMBER
OF
LEAD
4
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Cause
1
)
The
number
of
leads
for
the
selected
component
has
ex
in
the
T
2
"
"
3
"
and
"
4
"
text
boxes
of
the
label
component
library
data
.
icceeded
'
NUMB
the
parameters
specified
ER
OF
LEADS
1
'
in
the
(
Remedy
1
)
Check
the
selected
boxes
of
the
label
'
If
wrong
parameters
are
set
in
the
component
library
data
,
correct
them
.
nent
and
the
parameters
set
ER
OF
LEADS
"
in
the
co
:
;
tintheT
2
"
3
"
and
"
4
"
text
mponent
library
data
.
i
compor
"
NUMB
:
(
Display
C
)
1
L
905063
(
Display
A
)
Component
Library
Data
Error
(
Display
B
)
"
LEAD
DATA
PITCH
"
EXCEEDS
THE
RANGE
OF
SETTING
.
(
Cause
1
)
The
lead
pitch
of
the
selected
component
has
exceeded
the
parameter
specified
in
the
"
PITCH
"
text
box
of
the
label
"
LEAD
DATA
"
in
the
component
library
data
.
(
Remedy
1
)
Check
the
selected
component
and
the
1
"
LEAD
DATA
"
in
the
component
ter
set
in
the
"
PITCH
"
text
box
of
the
data
.
wrong
parameter
is
set
in
the
component
library
data
correct
it
.
labe
If
a
9910
-
001
ACP
01
EERW
3
-
23
3
-
23