DEUKYX 2-16 193-41 10 2.2 Management-Informationsliste Code Anzeigebereich A Anzeigebereich B 50406 Manual transfer There is PCB on Deceleration Sensor of Shuttle Conveyor in Output side. There is a possibility that PCB …

DEUKYX
2-15193-4110
2.2 Management-Informationsliste
Code Anzeigebereich A Anzeigebereich B
5020a
Conrmation of PCB
existence
There is a possibility that there are 2 sheets of PCB on the shuttle conveyor in
input side. Please remove PCB from Deceleration Sensor, or move it to Stop
sensor, or delete the PCB memory information.
5020b
Conrmation of PCB
existence
There is a possibility that there are 2 sheets of PCB on the shuttle conveyor in
output side. Please remove PCB from Deceleration Sensor, or move it to Stop
sensor, or delete the PCB memory information.
5020c
Conrmation of PCB
existence
There is PCB on the input sensor of Lane A. Please return PCB to the input
conveyor and run it.
5020d
Conrmation of PCB
existence
There is PCB on the input sensor of Lane B. Please return PCB to the input
conveyor and run it.
5020e
Conrmation of PCB
existence
There is PCB on the input sensor. Please return PCB to the input conveyor and
run it.
5020f
Conrmation of PCB
existence
There is no PCB in the machine. Please position a PCB.
50210
Conrmation of PCB
existence
Please put PCB on the positioning conveyor, and start it.
50211
Conrmation of PCB
existence
Please remove PCB from input position. Cutout PCB cannot be transferred
from input position.
50212
Conrmation of PCB
existence
Please remove the substrate at the upstream position. The substrate for weight
to exceed 2.5 kg cannot be transported simultaneously.
50213
Conrmation of PCB
existence
Please remove the substrate at A lane upstream position. The substrate for
weight to exceed 2.5 kg cannot be transported simultaneously.
50214
Conrmation of PCB
existence
Please remove the substrate at B lane upstream position. The substrate for
weight to exceed 2.5 kg cannot be transported simultaneously.
50215
Conrmation of PCB
existence
After a PCB disappears from the input conveyor of output machine, please
perform (PCB clip lump prevention).
Please switch on a power supply, when the power supply of output machine is
not on.
50216
Conrmation of PCB
existence
Please cancel positioning of a PCB and perform in the state where there is no
PCB.
50220
Conrmation of PCB
existence
2 PCB are between the input conveyor and the upstream position. Take PCB in
a one side.
50221
Conrmation of PCB
existence
A stop place of a PCB is unsettled. Please establish PCB memory information.
50222
Conrmation of PCB
existence
A PCB is on the upstream position stop sensor. Please put a PCB in the
location an upstream stop sensor doesn’t turn on.
50223
Conrmation of PCB
existence
It is not possible to operate, because there is a PCB in the upstream position.
50224
Conrmation of PCB
existence
Please put a P.C.B. in the location a deceleration sensor of a input conveyor
turns on.
50301
Conrmation of
Firmware version
Firmware of transfer driver is not the latest version. Please update it.
50401 Manual transfer
PCB (X > 260 mm) which is set by PP data is unable to be taken in Input
Position.
50402 Manual transfer
Please operate after removing PCB from output conveyor. There is a possibility
of pushing and rising with Stopper.
50403 Manual transfer
It is impossible to take from Sensor Detection of Input Position. Please put
PCB on Input Conveyor, or move it to Output position in Recovery Menu.
50404 Manual transfer
PCB (X > 260 mm) which is set by PP data is unable to be taken in Input
Conveyor.
50405 Manual transfer
There is PCB on Deceleration Sensor of Input Conveyor. There is a possibility
that PCB is inserted.

DEUKYX
2-16193-4110
2.2 Management-Informationsliste
Code Anzeigebereich A Anzeigebereich B
50406 Manual transfer
There is PCB on Deceleration Sensor of Shuttle Conveyor in Output side.
There is a possibility that PCB is inserted.
50407 Manual transfer
Lane A is not able to be set in Current Program. Please change Current
Program or change to Lane B.
50408 Manual transfer
Lane B is not able to be set in Current Program. Please change Current
Program or change to Lane A.
50409 Manual transfer
PCB Y size and Conveyor Width in Current Program are not equal. Please
change Current Program.
5040a Manual transfer Cutout PCB cannot be taken in input position.
5040b Manual transfer
Please remove PCB from input position. Cutout PCB cannot be transferred
from input position.
5040c Manual transfer It is not possible to transport it to the specied position.
5040d Manual transfer
It is not possible to operate because it interferes in the adsorption treatment
device.
5040e Manual transfer It composes the device, and it is not possible to operate.
5040f Manual transfer
PCB (X > 280 mm) which is set by PP data is unable to be taken in Input
Position.
50410 Manual transfer Output a PCB after interrupting operation.
50411 Manual transfer
It is not possible to operate, because there is a PCB in the upstream position.
Please take a PCB from upstream position.
50412 Manual transfer
It is not possible to operate, because there is a P.C.B. in the input conveyor.
Please take a P.C.B. in the input conveyor.
50501 Convert Width Setup
Please set conveyor width 49.5 ~ 461.5 mm. The total of PCB size/offset/
clearance is over movable range.
50502 Convert Width Setup
Please set conveyor width 49.5 ~ 382.5 mm. The total of PCB size/offset/
clearance is over movable range.
50503 Convert Width Setup
Movable Range for the destination of W1 is set. Please check PCB size/offset/
clearance of Lane A.
50504 Convert Width Setup
Movable Range for the destination of W1 is set. Please check PCB size/offset/
clearance of Lane A.
50505 Convert Width Setup
Movable Range for the destination of W2 is set. Please check PCB size/offset/
clearance of Lane A
50506 Convert Width Setup
Movable Range for the destination of W2 is set. Please check PCB size/offset/
clearance of Lane A.
50507 Convert Width Setup
Movable Range for the destination of W3 is set. Please check PCB size/offset/
clearance of Lane B.
50508 Convert Width Setup
Movable Range for the destination of W3 is set. Please check PCB size/offset/
clearance of Lane B.
50509 Convert Width Setup
These is a possibility of the interference with W1 and W2. Please check PCB
size/offset/clearance of Lane A.
5050a Convert Width Setup
There is a possibility of the interference with W2 and W3. Please Check PCB
size/offset/clearance of Lane A/B.
5050b Convert Width Setup
There is an interference between object position of Conveyor and Support Pin.
Please exchange Support Pin.
50510 Convert Width Setup Zeroing of W1 axis is not nished. Please perform zeroing of W1 axis.
50511 Convert Width Setup Zeroing of W2 axis is not nished. Please perform zeroing of W2 axis.
50512 Convert Width Setup Zeroing of W3 axis is not nished. Please perform zeroing of W3 axis.
50513 Convert Width Setup
The set value of W1 axis exceeds the soft limit. Please determine the value
within the range from 300.5 mm to 468.5 mm.

DEUKYX
2-17193-4110
2.2 Management-Informationsliste
Code Anzeigebereich A Anzeigebereich B
50514 Convert Width Setup
The set value of W1 axis exceeds the soft limit. Please determine the value
within the range from 368.5 mm to 536.5 mm.
50515 Convert Width Setup
The set value of W2 axis exceeds the soft limit. Please determine the value
within the range from 250.5 mm to 418.0 mm.
50516 Convert Width Setup
The set value of W2 axis exceeds the soft limit. Please determine the value
within the range from 284.5 mm to 452.0 mm.
50517 Convert Width Setup
The set value of W3 axis exceeds the soft limit. Please determine the value
within the range from 49.5 mm to 382.5 mm.
50518 Convert Width Setup
The set value of W3 axis exceeds the soft limit. Please determine the value
within the range from 83.5 mm to 416.5 mm.
50519 Convert Width Setup
There is an interference between W1 axis and W2 axis. Please change the
value or separate the interfering axis.
5051a Convert Width Setup
There is an interference between W2 axis and W3 axis. Please change the
value or separate the interfering axis.
5051b Convert Width Setup
Please set conveyor width 83.5~511.5 mm. The total of PCB size/offset/
clearance is over movable range.
5051c Convert Width Setup
Please set conveyor width 49.5~511.5 mm. The total of PCB size/offset/
clearance is over movable range.
50601 Convert Width Setup
Rotation Direction set of Middle Conveyor in supply side differs from Main
Device transfer direction. Please change the rotation direction of Middle
conveyor.
50602 Convert Width Setup
Emergency Stop switch of middle conveyor in supply side is pressed. Please
cancel it.
50603 Convert Width Setup Safety Cover of middle conveyor in supply side is open. Please close it.
50604 Convert Width Setup
Input Machine communication mode is set [PUSHER]. Cannot use [PUSHER]
mode when Middle Conveyor is contacted.
50611 Convert Width Setup
Rotation Direction set of Middle Conveyor in output side differs from Main
Device transfer direction. Please change the rotation direction of Middle
conveyor.
50612 Convert Width Setup
Emergency Stop switch of middle conveyor in output side is pressed. Please
cancel it.
50613 Convert Width Setup The Safety Cover of middle conveyor in output side is open. Please close it.
050701 Convert Width Setup
Emergency Stop Switch of Shuttle Conveyor in Input side is pressed. Please
cancel it.
050702 Convert Width Setup The safety cover of Shuttle Conveyor in Input side is open. Please close it.
050703 Convert Width Setup
Deceleration sensor of Shuttle Conveyor in Input side is detected. Please
remove PCB because there is a possibility that it is inserted.
050704 Convert Width Setup
Deceleration Sensor of Input Conveyor is detected. Please remove PCB
because there is a possibility that it is inserted.
050705 Convert Width Setup
Deceleration Sensor of Input Conveyor in Lane A is detected. Please remove
PCB because there is a possibility that it is inserted.
050706 Convert Width Setup
Deceleration Sensor of Input Conveyor in Lane B is detected. Please remove
PCB because there is a possibility that it is inserted.
050707 Convert Width Setup
Set Value of Delivery Position of Device System/Input Machine PCB is not in
the Movable Range. Please set the value 467 mm and less whose value is the
sum with Y size of PCB.
050708 Convert Width Setup
Please set [SMEMA] Mode for Device System/Input Machine Output. And,
Please conrm that Inp/Outp Machine Signal is set as [Enable].
050709 Convert Width Setup
Please set the same value in Lane A / Lane B of Delivery Position of Device
System/Input Machine PCB.