DEUKYX-193-4110_G5S2_VOL4.pdf - 第309页
DEUKYX 3-131 193-41 10 3.12 Fehler im Automatikbetrieb 3.12 Fehler im Automatikbetrieb Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung 510a01 Feeder Pocket recog Error Abnormality occurred in process of …

DEUKYX
3-130193-4110
3.11 Handhabungsfehler
3.11 Handhabungsfehler
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
500101 Comp. Missing (Sensor)
Comp. Missing (Sensor)
Prüfen Sie, ob das Bauteile auf den Feeder gefallen sind.
500301 Comp. Missing (Sensor)
Comp. Missing (Sensor)
Prüfen Sie, ob das Bauteile auf den Feeder gefallen sind. Wird ein gefederter
Aufnehmer verwendet, prüfen Sie die Funktion der Feder.
500401 Comp. Recog Error
Comp. Recog Error
-----
500501 Shortage of Component
Shortage of Component
-----
500502 Feeder Reload Stop
Feeder Reload Stop (Splicing)
-----
500c01 Comp. Vertical(Sensor)
Comp. Vertical(Sensor)
-----
500f01 Comp. Thickness(Sensor)
Comp. Thickness(Sensor)
-----
501001 Opt. Error(Feeder)
Feeder falls out
Feeder ausgefallen. Prüfen Sie, ob evtl. auch der Aufnehmer beschädigt wurde.
501101 Obverse/Reverse inspection error(Sensor)
Obverse/Reverse inspection error(Sensor)
-----

DEUKYX
3-131193-4110
3.12 Fehler im Automatikbetrieb
3.12 Fehler im Automatikbetrieb
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
510a01 Feeder Pocket recog Error
Abnormality occurred in process of recognizing Feeder Pocket.
-----
510b01 Auto Run Error
Master bad mark detection is abnormal.
-----
510b02 Auto Run Error
Bad mark detection is abnormal.
-----
510e01 Nozzle air blow Error(Head1)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510e02 Nozzle air blow Error(Head1)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510e03 Nozzle air blow Error(Head1)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510f01 Nozzle air blow Error(Head2)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510f02 Nozzle air blow Error(Head2)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510f03 Nozzle air blow Error(Head2)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
511001 Head1 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----
511002 Head1 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----

DEUKYX
3-132193-4110
3.12 Fehler im Automatikbetrieb
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
511003 Head1 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----
511004 Head1 Preparation Error
There is a possibility that Nozzle is falling while processing the preparation.
Please conrm the placed Nozzle on Head.
-----
511101 Head2 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----
511102 Head2 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----
511103 Head2 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----
511104 Head2 Preparation Error
There is a possibility that Nozzle is falling while processing the preparation.
Please conrm the placed Nozzle on Head.
-----
511201 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(L) are detected
simultaneously.
Prüfen Sie die Verkabelung und justieren Sie die Grenzwerte.
511202 Transfer Section's Preparation Error
Upward movement on PCB Stopper(L) is abnormal.
Möglicherweise ist der LP-Anschlag defekt oder die Luftzufuhr ist unterbrochen.
511203 Transfer Section's Preparation Error
Downward movement on PCB Stopper(L) is abnormal.
Möglicherweise ist der LP-Anschlag defekt oder die Luftzufuhr ist unterbrochen.
511204 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(R) are detected
simultaneously.
Prüfen Sie die Verkabelung und justieren Sie die Grenzwerte.
511205 Transfer Section's Preparation Error
Upward movement on PCB Stopper(R) is abnormal.
Möglicherweise ist der LP-Anschlag defekt oder die Luftzufuhr ist unterbrochen.
511206 Transfer Section's Preparation Error
Downward movement on PCB Stopper(R) is abnormal.