DEUKYX-193-4110_G5S2_VOL4.pdf - 第234页
DEUKYX 3-56 193-41 10 3.4 T ray-Feeder (Block1) 3.4 T ray-Feeder (Block1) Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung 430201 Tray Motor Error(Block1) Elevator abnormal stop ----- 430202 Tray Motor Er…

DEUKYX
3-55193-4110
3.3 Conveyor
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
42b602 Transfer check
Going down in the backup base(R) was not completed within the predetermined time.
-----
42b603 Transfer check
Going down in the backup base(AL) was not completed within the predetermined time.
-----
42b604 Transfer check
Going down in the backup base(AR) was not completed within the predetermined time.
-----
42b605 Transfer check
Going down in the backup base(BL) was not completed within the predetermined time.
-----
42b606 Transfer check
Going down in the backup base(BR) was not completed within the predetermined time.
-----

DEUKYX
3-56193-4110
3.4 Tray-Feeder (Block1)
3.4 Tray-Feeder (Block1)
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
430201 Tray Motor Error(Block1)
Elevator abnormal stop
-----
430202 Tray Motor Error(Block1)
Elevator abnormal stop
-----
430203 Tray Motor Error(Block1)
Traverse abnormal stop
-----
430301 Tray Rack Shutter open/close error (Block1)
The Rack Shutter did not open in prescribed time.
-----
430302 Tray Rack Shutter open/close error (Block1)
The Rack Shutter did not close in prescribed time.
Prüfen Sie, ob sich die Palette im Einschub verklemmt hat.
430401 Tray Pallet Chuck open/close error (Block1)
The Pallet Chuck did not open in prescribed time.
-----
430402 Tray Pallet Chuck open/close error (Block1)
The Pallet Chuck did not close in prescribed time.
-----
431001 Tray Supply Operation Error (Block1)
-----
431002 Tray Supply Operation Error (Block1)
Tray steps No. disagreement of draw out(return operation)
-----
431003 Tray Supply Operation Error (Block1)
Tray steps No. disagreement of draw out(return operation)
-----
431004 Tray Supply Operation Error (Block1)
The operation mode is illegal. (system)
-----
431005 Tray Supply Operation Error (Block1)
The position of TV axis is irregular
-----
431006 Tray Supply Operation Error (Block1)
Magazine classication disagreement
Führen Sie die Überprüfung von zehn Schritten vom Magazin und von 15 Schrit-
ten durch.
431101 Tray Pallet Returning Error (Block1)
Elevator pre-check error
-----

DEUKYX
3-57193-4110
3.4 Tray-Feeder (Block1)
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
431102 Tray Pallet Returning Error (Block1)
Elevator movement position error
-----
431103 Tray Pallet Returning Error (Block1)
Elevator wave form setting error
-----
431104 Tray Pallet Returning Error (Block1)
Elevator operating error
-----
431201 Tray Pallet Returning Error (Block1)
Traverse pre-check error
-----
431202 Tray Pallet Returning Error (Block1)
Traverse movement position error
-----
431203 Tray Pallet Returning Error (Block1)
Traverse wave form setting error
-----
431204 Tray Pallet Returning Error (Block1)
Traverse operating error
-----
431206 Tray Pallet Returning Error (Block1)
No palette when the return begins.(B15411)
-----
431301 Tray Pallet Draw out Error (Block1)
Elevator pre-check error
-----
431302 Tray Pallet Draw out Error (Block1)
Elevator movement position error
-----
431303 Tray Pallet Draw out Error (Block1)
Elevator wave form setting error
-----
431304 Tray Pallet Draw out Error (Block1)
Elevator operating error
-----
431305 Tray Pallet Draw out Error (Block1)
Elevator abnormal stop
-----
431401 Tray Pallet Draw out Error (Block1)
Traverse pre-check error
-----
431402 Tray Pallet Draw out Error (Block1)
Traverse movement position error
-----