DEUKYX-193-4110_G5S2_VOL4.pdf - 第324页
DEUKYX 3-146 193-41 10 3.13 Autom. T eaching Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung 60131 1 Noz stocker offset teaching Error of output-movement of Nozzle Stocker ----- 601401 T eaching Comp. Er…

DEUKYX
3-145193-4110
3.13 Autom. Teaching
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
601302 Noz stocker offset teaching
Error of XY-axis movement
-----
601303 Noz stocker offset teaching
Time-out in XY-axis movement
-----
601304 Noz stocker offset teaching
Error of HL-axis movement
-----
601305 Noz stocker offset teaching
Error of NL-axis movement
-----
601306 Noz stocker offset teaching
Error of L-axis movement
-----
601307 Noz stocker offset teaching
Error of HL/NL/L-axis movement
-----
601308 Noz stocker offset teaching
Nozzle stocker is not clamped
-----
601309 Noz stocker offset teaching
Error of Lighting On of P.C.B. Recognition Camera
-----
60.130a Noz stocker offset teaching
Timeout of Lighting On of P.C.B. Recognition Camera
-----
60130b Noz stocker offset teaching
Error of Lighting Off of P.C.B. Recognition Camera
-----
60130c Noz stocker offset teaching
Time-out of Lighting Off of P.C.B. Recognition Camera
-----
60130d Noz stocker offset teaching
Error of image capture of Nozzle Stocker Mark
-----
60130e Noz stocker offset teaching
Time-out of image capture of Nozzle Stocker Mark
-----
60130f Noz stocker offset teaching
Error of Recognition Performance of Nozzle Stocker Mark
-----
601310 Noz stocker offset teaching
Time-out of Recognition Performance of Nozzle Stocker Mark
-----

DEUKYX
3-146193-4110
3.13 Autom. Teaching
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
601311 Noz stocker offset teaching
Error of output-movement of Nozzle Stocker
-----
601401 Teaching Comp. Erkenn. Camera Magnication Teach
Time-out of communication with recognition.
Ist die Verbindung zur Erkennung unterbrochen? Bitte prüfen.
601402 Teaching Comp. Erkenn. Camera Magnication Teach
Error of Recognition Command response
-----
601a01 Side view camera correction re-teach
The Side View Camera reading is abnormal.
Prüfen Sie, ob der Aufnehmer an der Position haftet.
601a02 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis
-----
601a03 Side view camera correction re-teach
Nozzle can not be detected.
-----
601a04 Side view camera correction re-teach
Side View Camera Control is abnormal.
-----
601a05 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(All samples are E/R-Err7)
-----
601a06 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(All samples are E/NR-Err8)
Offset correction can not be completed. Please use the big nozzle(HA05) teach
-----
601a07 Side view camera correction re-teach
again and adjust the light & receive optical Axis(Edge detect error-Err9)
-----
601a08 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(Insufcient samples-Err10)
-----
601a09 Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach again
and adjust the light & receive optical Axis(Insufcient correcting samples-Err14)
-----
601a0a Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(Fail to create correction-Err15)
-----

DEUKYX
3-147193-4110
3.13 Autom. Teaching
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
601a0b Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(Accuracy check NG-Err16)
-----
601a0c Side view camera correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(Fail to save-Err17)
-----
601a0d Side view camera correction re-teach
The measurement value of the nozzle is not within 0.2mm to 0.6mm.
Justieren Sie die Höhe der Seitenansichtkamera oder tauschen Sie sie aus.
601a0e Side view camera correction re-teach
The Side View Camera control has an error.(err2, err3)
Alle E/NR-Fehler. Es besteht die Möglichkeit, dass die Lichtquelle oder der
Empfänger defekt ist.
601a0f Side view camera correction re-teach
The Side View Cameracontrol has an error.(err1)
Kann ein LP-Fehler sein. Fehler
601a10 Side view camera correction re-teach
The Side View Camera control has an error.(err4)
Die Abstrahlung der Lichtquelle ist zu niedrig. Es besteht die Möglichkeit, dass die
Lichtquelle defekt ist.
601a11 Side view camera correction re-teach
No strobe response
Prüfen Sie die HLS-Verkabelung. Prüfen Sie die LP-Adresse.
601f01 NL Axis offset teach
Error before Side View Camera measurement began
-----
601f02 NL Axis offset teach
ODD Noz is placed on Head, or error is detected during side view camera.
-----
601f03 NL Axis offset teach
Error of NS-axis movement
-----
601f04 NL Axis offset teach
Error of DD-axis movement
-----
601f05 NL Axis offset teach
Error of NL-axis movement
-----
601f06 NL Axis offset teach
Error of DD/NS-axis movement
-----
601f07 NL Axis offset teach
Time-out when Side View Camera measurement began
-----
601f08
NL Axis offset teach
Read Time-out of Side View Camera measurement
-----