DEUKYX-193-4110_G5S2_VOL4.pdf - 第349页
DEUKYX 3-171 193-41 10 3.17 ACV 3.17 ACV Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung 740305 ACV: Feeder Location Error Feeder location error is found on tray (Block1). Prüfen Sie die Bauteilposition …

DEUKYX
3-170193-4110
3.16 Barcode-Erkennung
3.16 Barcode-Erkennung
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
700101 Barcode-Erkennung
The bar code data is not read.
-----
700102 Barcode-Erkennung
The pattern program is not found.
-----
700111 Barcode-Erkennung
Program -change was not able to executed.
-----
700112 Barcode-Erkennung
Application error.
-----
700114 Barcode-Erkennung
The product.operation was not able to begin.
-----
700115 Barcode Detection
Bar Code Program-change process cannot be excuted "PRODUCT.SCRN", or
"COMP.RELD.SCRN."
-----
700118 Barcode Detection
Illegal bar code ID.
-----
700119 Barcode Detection
Bar code ID effective range is illegal.
-----
700120 Barcode Detection
Ptn.Prgm. specied by Crnt.Prgm. and barcode is different.
-----
700125 Barcode Detection
2D bar code mode of the pattern program is "Disable".
-----
700151 Barcode Detection
It is impossible to change Barcode on the Dual machine.
-----
700152 Barcode Detection
Current program is not set.
-----
700153 Barcode Detection
PCB nishing position of Pattern Program for Program Change is set except [Input]
and [Output].
-----
700154 Barcode Detection
PCB nishing position Setup in Pattern Program differs before and after Program
Change.
-----

DEUKYX
3-171193-4110
3.17 ACV
3.17 ACV
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
740305 ACV: Feeder Location Error
Feeder location error is found on tray (Block1).
Prüfen Sie die Bauteilposition und führen Sie eine neue Registrierung durch.
740306 ACV: Feeder Location Error
Feeder location error is found on tray (Block2).
Prüfen Sie die Bauteilposition und führen Sie eine neue Registrierung durch.
740501 ACV Time-out
Device(Block1) Time-out in receiving the result of ACV Check Error. Component
ID on the feeder is not same as one specied by current program.
-----
740502 ACV Time-out
Device(Block2) Time-out in receiving the result of ACV Check Error. Component
ID on the feeder is not same as one specied by current program.
-----
740605 ACV feeder check
Tray(Block1) parts empty.
Supply parts and register one.
-----
740606 ACV feeder check
Tray(Block2) parts empty.
Supply parts and register one.
-----
740701 ACV server timeout
ACV server process didn't respond in proper time.
-----
740702 ACV server timeout
-----
-----
740703 ACV server timeout
Error in an internal data ACV communication program. Please turn off a breaker.
-----
740704 ACV server timeout
Errors in the format of retrieval result of the ACV database.
-----
740705 ACV server timeout
Failed in the access to the ACV database.
-----
740706 ACV server timeout
The waiting time of the ACV database backup processing was exceeded.
-----
740707 ACV server timeout
There was no communication response from the ACV database.
-----

DEUKYX
3-172193-4110
3.17 ACV
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
740708 ACV server timeout
There was no communication response from the CPU1.
-----
740801 ACV check
The S/N of the machine didn't log in ACV server
-----
740802 ACV check
The S/N of the operator didn't log in ACV server
-----
740a01 ACV check
Starting of ACV tray tag reading went wrong.
-----
740f01 ACV check
Splicing registration failed.
-----
740f02 ACV check
Splicing registration failed for the unused feeder.
-----
740f03 ACV check
Abnormality was found in the connection with the ACV server. Please conrm the
ACV server. Please execute the server connection again on "MAINTENANCE"-
"UNIT ADJ"-"ACV ADJ"-screen after it conrms it.
-----