456.pdf - 第12页
12 Dry Film Thickness - Digital Accuracy a : ±1-3% or ±2.5μm ±1-3% or ±0.1mil Range: 0-500μm 0-20mils Resolution: 0.1μm: 0-100μm 1μm: 100-500μm 0.01mil: 0-5mils 0.1mil: 5-20mils Certicate: ● 1 2 3 4 5 6 7 8 Scale 0.5 Pr…

elcometer.com
11
Dry Film Thickness - Digital
Elcometer 456
Angled Probes
Probe Range for Separate Coating Thickness GaugeElcometer 456
Choosing the correct probe for your coating thickness gauge:
Take readings in areas
with restricted clearance.
Right Angle Probe
Extending probes for hard
to reach areas.
Telescopic Probe
For measuring coatings
on edges, narrow pipes
or small surface areas.
Mini Right Angle Probe
Measure difcult to
access or complex
areas.
45° Angle Probe
Plug In Integral Probes (PINIP™)
Transforms a separate
gauge into an integral
gauge, ideal for single
handed use.
PINIP™ Integral Probe
Measure coatings on
ferrous substrates up to
250°C (480°F).
Hi-Temperature PINIP™
Armoured Cable Probes
Reinforced heavy duty cables reduce the risk of cable damage.
F / FNF Armoured Probe

12
Dry Film Thickness - Digital
Accuracy
a
: ±1-3% or ±2.5μm ±1-3% or ±0.1mil
Range: 0-500μm 0-20mils
Resolution:
0.1μm: 0-100μm
1μm: 100-500μm
0.01mil: 0-5mils
0.1mil: 5-20mils
Certicate: ●
1
2
3
4
5
6
7
8
Scale 0.5 Probe Range 0-500μm / 0-20mils
Probe Range for Separate Coating Thickness GaugeElcometer 456
See '#' on the probes table on the opposite page for comparison.
c. Probe length is measured from X to Y
d. for Elcometer 456 Model T gauges only
Elcometer 456 probes are covered by a 1 year warranty
a. Whichever is the greater
b. FNF (F): FNF probe in F Mode FNF (N): FNF probe in N Mode
● Certicate supplied as standard.
X Y

elcometer.com
13
Dry Film Thickness - Digital
a. Whichever is the greater
b. FNF (F): FNF probe in F Mode FNF (N): FNF probe in N Mode
● Certicate supplied as standard.
Ferrous (F) Probes
#
Description Probe Length
c
Part Number
Minimum
Headroom
Minimum Sample
Diameter
b
6
45° Angle Mini Probe 45mm (1.77”) T456CFM7R45A
d
20mm (0.79”) 6.5mm (0.26’’)
Ferrous (F) Probes
#
Description Probe Length
c
Part Number
Minimum
Headroom
Minimum Sample
Diameter
b
2
45° Angle Mini Probe 300mm (11.80”) T456CFM3R45D 18mm (0.71”) 3mm (0.12”)
3
Right Angle Mini Probe 300mm (11.80”) T456CFM3R90D 16mm (0.63”) 3mm (0.12”)
4
Right Angle Mini Probe 150mm (5.90”) T456CFM3R90C 16mm (0.63”) 3mm (0.12”)
5
Straight Mini Probe 150mm (5.90”) T456CFM3---C 6mm (0.24”) 3mm (0.12”)
6
45° Angle Mini Probe 45mm (1.77”) T456CFM3R45A 16mm (0.63”) 3mm (0.12”)
7
Right Angle Mini Probe 45mm (1.77”) T456CFM3R90A 16mm (0.63”) 3mm (0.12”)
8
Straight Mini Probe 45mm (1.77”) T456CFM3---A 6mm (0.24”) 3mm (0.12”)
Non-Ferrous (N) Probes
#
Description Probe Length
c
Part Number
Minimum
Headroom
Minimum Sample
Diameter
b
1
Right Angle Mini Probe 400mm (15.70”) T456CNM3R90E 16mm (0.63”) 4mm (0.16”)
4
Right Angle Mini Probe 150mm (5.90”) T456CNM3R90C 16mm (0.63”) 4mm (0.16”)
5
Straight Mini Probe 150mm (5.90”) T456CNM3---C 6mm (0.24”) 4mm (0.16”)
7
Right Angle Mini Probe 45mm (1.77”) T456CNM3R90A 16mm (0.63”) 4mm (0.16”)
8
Straight Mini Probe 45mm (1.77”) T456CNM3---A 6mm (0.24”) 4mm (0.16”)
Non-Ferrous - Graphite (N)
#
Description Probe Length
c
Part Number
Minimum
Headroom
Minimum Sample
Diameter
b
1
Right Angle Mini Probe 400mm (15.70”) T456CNMG3R90E 16mm (0.63”) 4mm (0.16”)
4
Right Angle Mini Probe 150mm (5.90”) T456CNMG3R90C 16mm (0.63”) 4mm (0.16”)
7
Right Angle Mini Probe 45mm (1.77”) T456CNMG3R90A 16mm (0.63”) 4mm (0.16”)
Probe Range for Separate Coating Thickness GaugeElcometer 456
Accuracy
a
: ±7.5% or ±114μm ±7.5% or ±4.5mils
Range
d
: 0.60-3.8mm 25-150mils
Resolution:
1μm: 0-1mm
10μm: 1-3.8mm
0.1mil: 0-139.3mils
1.0mil: 39.4-150mils
Certicate: ●
Scale FM7 Probe Range 0.6-3.8mm / 25-150mils
Scale 0.5 Probe Range 0-500μm / 0-20mils