456.pdf - 第30页
30 Dry Film Thickness - Foils & Standards elcometer.com/videos * T o be used only with the Elcometer 31 1 or Elcometer 415 ○ Optional Calibration Certicate available. Elcometer provides a range of Zero T est Plates.…

elcometer.com
29
Dry Film Thickness - Foils & Standards
Using Calibration Foils
Description Foil Values (μm) Foil Values (mils) Un-Certied Certied
Scale 1 Foil Set; 0-1500μm
(0-60mils)
25, 50, 125, 250, 500,
1,000
1.0, 2.0, 5.0, 10, 20, 40 T99022255-1 T99022255-1C
Scale 2 Foil Set; 0-5mm
(0-200mils)
25, 50, 125, 250, 500,
1,000, 2,000, 3,000
1.0, 2.0, 5.0, 10, 20, 40,
80, 120
T99022255-2 T99022255-2C
Scale 3 Foil Set; 0-13mm
(0-500mils)
250, 500, 1,000, 2,000,
4,000, 8,000
10, 20, 40, 80, 160, 315 T99022255-3 T99022255-3C
Scale 4 Foil Set; 0-250µm
(0-10mils)
12.5, 25, 50, 125, 250 0.5, 1.0, 2.0, 5.0, 10 T99022255-4 T99022255-4C
Scale 5 Foil Set; 0-800μm
(0-32mils)
12.5, 25, 50, 125, 250, 500 0.5, 1.0, 2.0, 5.0, 10, 20 T99022255-5 T99022255-5C
Scale 6 Foil Set; 0-30mm
(0-1200mils)
1,000, 2,000, 5,000, 9,500,
15mm, 25mm
40, 80, 200, 375, 590, 980 T99022255-6 T99022255-6C
Scale M3 Foil Set; 0-500μm
(0-20mils)
12.5, 25, 50, 125, 250, 500 0.5, 1.0, 2.0, 5.0, 10, 20 T99022255-7 T99022255-7C
Scale 2B Foil Set*; 0-5mm
(0-200mils)
25, 50, 125, 250, 500,
1,000, 2,000, 2,000
1.0, 2.0, 5.0, 10, 20, 40,
80, 80
T99022255-8 T99022255-8C
The Elcometer 990 Calibration Foils are ideal for use in the laboratory, on the
production line or on site. Calibration foils or ‘shims’ are the most convenient way
of creating a coating thickness standard on the substrate material, surface nish or
form. This is the ideal method for adjusting the calibration of the coating thickness
gauge to ensure the greatest possible accuracy.
Features:
• Metric and Imperial values displayed on each foil
• Available individually or in foil sets
• Precision foils with ±1% accuracy
• Each foil has a unique serial number for traceability
• Available in thicknesses from 12.5μm to 20mm (0.5 to 790mils)
* The Scale 2B foil sets are designed for soft coating probes and have a larger foil surface area.
Each foil has been independently measured at the
centre point.
For the greatest accuracy, place the probe in the
centre of the foil.
Up to 4 foils can be combined to create a wider range
of thickness values.
t
u
Calibration Foils SetsElcometer 990
Technical Specication

30
Dry Film Thickness - Foils & Standards
elcometer.com/videos
* To be used only with the Elcometer 311 or Elcometer 415
○ Optional Calibration Certicate available.
Elcometer provides a range of Zero Test Plates. When used in conjunction with a
set of foils, Test Plates are ideal to test a coating thickness gauge’s functionality.
For a list of standards, foils and foil sets, see page 7-46.
Description Size Size Ferrous Non-Ferrous Certicate
Precision Zero Test Plate (±1%) 50.8 x 25.4mm 2.0 x 1.0” T9994910- T9994911-
Zero Test Plate 76.2 x 50.8mm 3.0 x 2.0” T9999529- T9999530-
Zero Test Plate (large) 76.2 x 101.6mm 3.0 x 4.0” T9994054- T9994055- ○
Steel (F) Checkpiece* 50.8 x 88.9mm 2.0 x 3.5” T99916925 -
Aluminium (N) Checkpiece* 50.8 x 88.9mm 2.0 x 3.5” - T99916901
Zero Test PlatesElcometer 990
Technical Specication
video available
tv
elcometer.tv

elcometer.com
31
elcometer.com/videos
Generate professional reports at the click of
a button and email to your client seconds
after you have nished inspecting.
With the ElcoMaster
®
Software App your
ofce is now wherever you are.
elcometer.com