456.pdf - 第5页

elcometer.com 5 Dry Film Thickness - Digital 1 When tested on smooth surfaces probe end caps have been scanned in excess of 50km (30 miles) Scan Probes The Scan Probes further enhance the speed and accuracy of eld based…

100%1 / 32
4
Dry Film Thickness - Digital
* Scan and Auto Repeat Modes require an Elcometer 456 Model T gauge with Scan Probe.
Scan and Auto Repeat Modes
Using the Scan Probe in Scan Mode
Using the Elcometer 456 with the Scan Probe in scan mode enables users
to signicantly reduce dry lm thickness inspection times without a󰀨ecting
accuracy:
Slide the Scan Probe over the entire surface area, as the probe is lifted o󰀨
the surface the gauge displays the average coating thickness value, the
highest thickness and the lowest thickness values.
Each set of three readings (average, high and low) can be displayed on the
run graph and stored into the memory.
Using the Scan Probe in Auto Repeat Mode
When the Scan Probe is slid over the coated surface in Auto Repeat Mode*,
a coating thickness reading is taken approximately every half a second. Each
individual dry lm thickness reading is stored into the memory.
With a reading rate in excess of 140 readings per minute, the Auto Repeat
Mode can signicantly speed up the dry lm thickness inspection of large
coated areas.
Separate Coating Thickness GaugeElcometer 456
During each scan the Elcometer 456 displays the live thickness reading together with an analogue bar
graph
which graphically indicates the thickness relative to both the nominal thickness and any user-dened limits.
elcometer.com
5
Dry Film Thickness - Digital
1
When tested on smooth surfaces probe end caps have been scanned in excess of 50km (30 miles)
Scan Probes
The Scan Probes further enhance the speed and accuracy of eld based dry
lm coating thickness measurement:
Featuring a highly durable ‘snap on’ replaceable probe cap
A revolutionary design which allows users to take individual readings or
rapidly scan large surface areas - without damaging the probe or coating
Any cap wear during use
1
is incorporated within the calibration process -
the gauge even informs the user when to replace the cap.
Standard Scan Probe or larger Roller Bearing Scan Probe available
Roller Bearing Scan Probe is ideal for large coated structures, abrasive
coatings and pre-construction primers.
Counted Average and Fixed Batch Modes
Counted Average Mode
The Elcometer 456 Model S and Model T are supplied with the Counted
Average Mode
Once the user has dened the number of individual gauge readings to be
taken within a spot measurement, the gauge stores the average of the
individual gauge readings into the memory.
Working with Standards and Test Methods
International Standards and test methods often describe the number of
individual gauge readings to be taken in a spot measurement and/or the
number of spot measurements required over a dened surface area.
SSPC PA2 requires a minimum of three gauge readings to be taken per
spot measurement and ve spot measurements over 10m
2
(~100ft
2
).
The Elcometer 456 Model S or Model T can be set with a counted average
of three and a xed batch size of ve to meet these requirements. Each
batch denes an area of measurement.
When the Scan Probe is connected to the Elcometer 456 Model T with
Auto Repeat Mode selected, SSPC PA2 (or similar test methods) can be
completed more than 40% faster.
Fixed Batch Sizes
The Fixed Batch Size feature within the Elcometer 456 Model T allows
users to dene the maximum number of readings in each batch.
Once the maximum number of readings has been reached the gauge automatically opens up a new batch
which is linked to the previous batch (name-1, name-2, etc.).
Separate Coating Thickness GaugeElcometer 456
6
Dry Film Thickness - Digital
Model B Model S Model T
Fast, accurate reading rate; 70+ readings per minute
Repeatable & reproducible measurements
Easy to use menu structure; in 30+ languages
Tough, impact, waterproof & dust resistant; equivalent to IP64
Bright colour screen; with permanent backlight
Scratch & solvent resistant display; 2.4” (6cm) TFT
Large positive feedback buttons
USB power supply; via PC
Test certicate
2 year gauge warranty
1
Automatic rotating display; 0°, 90°, 180° & 270°
Ambient light sensor; with adjustable auto brightness
Emergency light
Tap awake from sleep
Gauge software updates
2
; via ElcoMaster
®
software
Data output
USB; to computer
Bluetooth
®
; to computer, Android
& iOS
3
devices
On screen statistics
Number of readings; η Mean (average); x Standard deviation; σ
Highest reading; Hi Lowest reading; Lo Coe󰀩cient of variation; CV%,
Elcometer index value
4
; EIV
Nominal dry lm thickness; NDFT
IMO PSPC; %>NDFT, %>90<NDFT, 90:10 pass/fail
High & low limits; denable audible & visual alarms
Number of readings above high limit;
Number of readings below low limit;
Live reading trend graph; in Batch Mode
ElcoMaster
®
software & USB cable
Replaceable screen protectors
Protective case
Plastic transit case
Separate models; with automatic probe recognition
Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)
F, N, FNF F, N, FNF F, N, FNF
Measurement range; see page 7-12 for probe selection
0-31mm
0-1,220mils
0-31mm
0-1,220mils
0-31mm
0-1,220mils
On screen calibration instructions; in 30+ languages
Multiple calibration methods
Factory; resets to the factory calibration
2-point; for smooth and rough surfaces
1-point; zero calibration
Zero o󰀨set; for calibration according to ISO19840
Predened calibration & measurement methods
ISO, SSPC PA2, Swedish, Australian
1
The Elcometer 456 is supplied with a 1 year warranty against manufacturing defects. The warranty can be extended free of charge to 2 years within 60 days of purchase via
www.elcometer.com.
2
Internet connection required
3
Visit www.elcometer.com/sdk to find out how to integrate Elcometer’s MFi certified products to your App.
4
Elcometer Index Values are used in the automotive industry to assess a coating’s overall quality; USA Patent Number US7606671B2
Separate Coating Thickness GaugeElcometer 456
Product Features
Standard Optional