456.pdf - 第9页

elcometer.com 9 Dry Film Thickness - Digital Probe Range for Separate Coating Thickness Gauge Elcometer 456 Ferrous Probes (F) • Ferrous probes measure non-magnetic coatings on ferromagnetic substrates. • Elcometer 456 f…

100%1 / 32
8
Dry Film Thickness - Digital
Probe Range for Separate Coating Thickness GaugeElcometer 456
All Elcometer 456 probes are fully interchangeable and are
available in a number of designs and scale ranges to meet your
specic application, including;
All Elcometer 456 probes are available in a number of designs
and scale ranges to meet your specic application.
Supplied with a Test
Certicate and a set of
calibration foils
Ferrous, non-ferrous and
dual FNF probes available
Fully interchangeable and
available in a number of
designs and scale ranges
Ergonomic design, ideal
for continuous use
Temperature stable
measurements
elcometer.com
9
Dry Film Thickness - Digital
Probe Range for Separate Coating Thickness GaugeElcometer 456
Ferrous Probes (F)
Ferrous probes measure non-magnetic
coatings on ferromagnetic substrates.
Elcometer 456 ferrous gauges accept any
ferrous probe.
Non-ferrous probes measure non-conductive
coatings on non-ferrous metal substrates.
Elcometer 456 non-ferrous gauges accept
any non-ferrous probe.
Non-Ferrous Probes (N)
Dual Probes (FNF)
Dual FNF probes measure both ferrous and
non-ferrous applications with automatic
substrate detection.
Elcometer 456 FNF gauges accept all ferrous,
non-ferrous and dual FNF probes.
Choosing the correct probe for your coating thickness gauge:
Elcometer probes have a maximum
operating temperature of 80°C (176°F)
*
.
Separate ferrous probes have a maximum
operating temperature of 150°C (300°F)
*
.
Hi-Temperature PINIP
has a maximum
operating temperature of 250°C (480°F)
*
.
High Temperature
*The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.
10
Dry Film Thickness - Digital
Scan Probes
Straight Probes
Probe Range for Separate Coating Thickness GaugeElcometer 456
Choosing the correct probe for your coating thickness gauge:
Standard probes measure
coatings on both at and
curved surfaces.
Standard Straight Probe
Mini probes are ideal for
harder to reach areas
and edges.
Mini Probe
Large surface area
probes are for soft
materials (HVCA
approved).
Soft Coating Probe
Chemical resistant &
washable - ideal for the
anodising environment.
Anodising Probe
Sealed for use
underwater at depth,
even in diving gloves.
Waterproof Probe
Ideal for measuring
coatings up to 31mm
thick.
Thick Coatings Probe
Rapidly scan large
surface areas without
damaging the probe or
the coating.
Standard Scan Probe
Clip on adaptors for
large coated structures,
abrasive coatings and
pre-construction primers.
Ball Bearing Scan Probe
1
1
UK Patent Number: 2571577