456.pdf - 第13页

elcometer.com 13 Dry Film Thickness - Digital a. Whichever is the greater b. FNF (F): FNF probe in F Mode FNF (N): FNF probe in N Mode ● Certicate supplied as standard. Ferrous (F) Probes # Description Probe Length c Pa…

100%1 / 32
12
Dry Film Thickness - Digital
Accuracy
a
: ±1-3% or ±2.5μm ±1-3% or ±0.1mil
Range: 0-500μm 0-20mils
Resolution:
0.1μm: 0-100μm
1μm: 100-500μm
0.01mil: 0-5mils
0.1mil: 5-20mils
Certicate:
1
2
3
4
5
6
7
8
Scale 0.5 Probe Range 0-500μm / 0-20mils
Probe Range for Separate Coating Thickness GaugeElcometer 456
See '#' on the probes table on the opposite page for comparison.
c. Probe length is measured from X to Y
d. for Elcometer 456 Model T gauges only
Elcometer 456 probes are covered by a 1 year warranty
a. Whichever is the greater
b. FNF (F): FNF probe in F Mode FNF (N): FNF probe in N Mode
Certicate supplied as standard.
X Y
elcometer.com
13
Dry Film Thickness - Digital
a. Whichever is the greater
b. FNF (F): FNF probe in F Mode FNF (N): FNF probe in N Mode
Certicate supplied as standard.
Ferrous (F) Probes
#
Description Probe Length
c
Part Number
Minimum
Headroom
Minimum Sample
Diameter
b
6
45° Angle Mini Probe 45mm (1.77”) T456CFM7R45A
d
20mm (0.79”) 6.5mm (0.26’’)
Ferrous (F) Probes
#
Description Probe Length
c
Part Number
Minimum
Headroom
Minimum Sample
Diameter
b
2
45° Angle Mini Probe 300mm (11.80”) T456CFM3R45D 18mm (0.71”) 3mm (0.12”)
3
Right Angle Mini Probe 300mm (11.80”) T456CFM3R90D 16mm (0.63”) 3mm (0.12”)
4
Right Angle Mini Probe 150mm (5.90”) T456CFM3R90C 16mm (0.63”) 3mm (0.12”)
5
Straight Mini Probe 150mm (5.90”) T456CFM3---C 6mm (0.24”) 3mm (0.12”)
6
45° Angle Mini Probe 45mm (1.77”) T456CFM3R45A 16mm (0.63”) 3mm (0.12”)
7
Right Angle Mini Probe 45mm (1.77”) T456CFM3R90A 16mm (0.63”) 3mm (0.12”)
8
Straight Mini Probe 45mm (1.77”) T456CFM3---A 6mm (0.24”) 3mm (0.12”)
Non-Ferrous (N) Probes
#
Description Probe Length
c
Part Number
Minimum
Headroom
Minimum Sample
Diameter
b
1
Right Angle Mini Probe 400mm (15.70”) T456CNM3R90E 16mm (0.63”) 4mm (0.16”)
4
Right Angle Mini Probe 150mm (5.90”) T456CNM3R90C 16mm (0.63”) 4mm (0.16”)
5
Straight Mini Probe 150mm (5.90”) T456CNM3---C 6mm (0.24”) 4mm (0.16”)
7
Right Angle Mini Probe 45mm (1.77”) T456CNM3R90A 16mm (0.63”) 4mm (0.16”)
8
Straight Mini Probe 45mm (1.77”) T456CNM3---A 6mm (0.24”) 4mm (0.16”)
Non-Ferrous - Graphite (N)
#
Description Probe Length
c
Part Number
Minimum
Headroom
Minimum Sample
Diameter
b
1
Right Angle Mini Probe 400mm (15.70”) T456CNMG3R90E 16mm (0.63”) 4mm (0.16”)
4
Right Angle Mini Probe 150mm (5.90”) T456CNMG3R90C 16mm (0.63”) 4mm (0.16”)
7
Right Angle Mini Probe 45mm (1.77”) T456CNMG3R90A 16mm (0.63”) 4mm (0.16”)
Probe Range for Separate Coating Thickness GaugeElcometer 456
Accuracy
a
: ±7.5% or ±114μm ±7.5% or ±4.5mils
Range
d
: 0.60-3.8mm 25-150mils
Resolution:
1μm: 0-1mm
10μm: 1-3.8mm
0.1mil: 0-139.3mils
1.0mil: 39.4-150mils
Certicate:
Scale FM7 Probe Range 0.6-3.8mm / 25-150mils
Scale 0.5 Probe Range 0-500μm / 0-20mils
14
Dry Film Thickness - Digital
Accuracy
ae
: ±1-3% or ±2.5μm ±1-3% or ±0.1mil
Range
d
: 0-1,500μm 0-60mils
Resolution:
0.1μm: 0-100μm
1μm: 100-1,500μm
0.01mil: 0-5mils
0.1mil: 5-60mils
Certicate:
Scale 1 Probe Range 0-1500μm / 0-60mils
1
2
3
4
5
6
7
8
Probe Range for Separate Coating Thickness GaugeElcometer 456
c. Probe length is measured from X to Y
d. Excluding Scan Probe end cap
e. Scan Probe calibrated using a sample of the uncoated substrate
Elcometer 456 probes are covered by a 1 year warranty
a. Whichever is the greater
b. FNF (F): FNF probe in F Mode FNF (N): FNF probe in N Mode
Certicate supplied as standard.
X Y
See '#' on the probes table on the opposite page for comparison.