00195813-05_IM_SSW_605.03_SP1_DE EN.pdf - 第11页
Installation Manual, Station Software Version 605.03 SP1 07/2011 Edition 4 Requirement s 4.1 SIPLACE X-series, D-series and CA-series sof tware components 4.1.1 Station The station uses the following ope rating system co…

Installation Manual, Station Software Version 605.03 SP1 07/2011 Edition
- After an upgrade to the 605.xx software version, calibrate the heads of the D1, D2 and D4 machines.
The temperature compensation is activated for these machines.
10 of 48

Installation Manual, Station Software Version 605.03 SP1 07/2011 Edition
4 Requirements
4.1 SIPLACE X-series, D-series and CA-series software components
4.1.1 Station
The station uses the following operating system configuration:
• Station computer: Microsoft Windows XP Professional
(including Service Pack 2 and most recent hotfixes)
• Machine controller: Microsoft Windows embedded XP (SP2)
4.1.2 Machine components
The following versions of other machine components are required for the station software to function
correctly:
Station computer SIPLACE Vision Machine controller SIPLACE Pro
Version 605.03 SP1 Version 413 Version 605.03 SP1 Version 8.0
CAUTION
The functional statuses of the station computer, vision, machine controller and SIPLACE Pro
software must be compatible.
11 of 48
Installation Manual, Station Software Version 605.03 SP1 07/2011 Edition
12 of 48
4.1.3 Embedded software
You will find the used eSW versions listed in the eSW_Firmware_Files.txt file in the Documentation
directory on the installation CD.
The hardware status of a subsystem is identified by the 3rd digit in the file name.
The example below shows the file name of the BIOS for the main axes of the X-Series:
File name Hardware status
A0
300200.bhx A 363
A0
400309.bhx A 364