Installation Manual, Station Software Version 605.03 SP1 07/2011 Edition Fig.5-24: Shutting down the station computer, machine controller and Vision computer → Switch the machi ne off when the computer system s have shut…

100%1 / 96
Installation Manual, Station Software Version 605.03 SP1 07/2011 Edition
→ Close the applications listed here and then click the Retry button.
The installation program now installs the additional programs on the station computer.
5.4.8 Finalizing the installation
NOTICE
The status only lists the programs that have just been installed. If, for instance, the current
version of SIPLACE Vision was already installed, it is not listed here.
If errors occurred during installation, the status is indicated by the Error button being
displayed next to the program name instead of the Ok button.
→ If you wish to read the log of the installation of any program, click the Ok (or Error) button next to the
name of the program. Notepad is started and displays the appropriate file.
Fig. 5-23: Finalizing the installation
→ Click the Finish button.
NOTICE
To establish the connection between the station computer and the machine controller after
installation has been completed, the station computer, machine controller and Vision
computer (if present) must first be run down and the machine must then be switched off
completely.
→ To do this, open the Start menu and select Programs Æ SIPLACE Æ Shutdown_Vision_MC_SR
(all).
37 of 48
Installation Manual, Station Software Version 605.03 SP1 07/2011 Edition
Fig.5-24: Shutting down the station computer, machine controller and Vision computer
→ Switch the machine off when the computer systems have shut down.
→ Switch the machine back on again. This then reboots the station computer, the machine controller and
the Vision computer (if present).
38 of 48
Installation Manual, Station Software Version 605.03 SP1 07/2011 Edition
39 of 48
5.5 Finish the installation
5.5.1 Miscellaneous
• Check the eSW firmware versions and download if necessary.
• Start the reference run of the machine.
• After an upgrade to the 605.xx software version, calibrate the heads of the D1, D2 and D4
machines, if necessary. The temperature compensation is activated for these machines.
If the data base for the axes has changed after an upgrade or an installation, and one or more gantry axes
(X,Y) are displaced by exactly 50mm, the reference point on the axis/axes scale has been displaced by
one position and the zero point correction is not correct for these axes anymore. In this case the following
steps are required:
• Recalibrate the machine zero point.
• Redetermine the traversing range.