TM3355.CheckNozzleBuffingFunctionSpecifications.pdf - 第11页

Y AMAHA M otor Co. Ltd ., IM Company SMT Software Engineering Grou p MDOC-SOFT50 052 11 /27 W hen nozzle buffing chec k finished n ormall y , the [Unit] - [Head] - [Buff in g check ] - [Last chec k inform ation] button b…

100%1 / 27
YAMAHA Motor Co. Ltd.,
IM Company
SMT Software Engineering Group
MDOC-SOFT50052
10/27
Table 4.2.4 Nozzle buffing check execution result list
Result Details
Correctly
Abnormality was not found in the nozzle buffing.
Low
Level
Buffing
Error
The nozzle has slight friction with the buffing action.
Proceed maintenance operation and confirm whether the buffing action is
smooth.
Even if the buffing action is smooth, when the following setting have wrong
value or it is a different setup from an actual nozzle, this error will occur.
(1)[Buffing check spec]-[Measurement height]
(2)[Nozzle Data]-[Length]
Middle
Level
Buffing
Error
The nozzle has friction with the buffing action, or the nozzle is clogged up.
Proceed maintenance operation for the nozzle.
If nozzle don't recover good condition, recommend exchange to spare nozzle.
Even if the buffing action is smooth, when the following setting have wrong
value or it is a different setup from an actual nozzle, this error will occur.
(1)[Buffing check spec]-[Measurement height]
(2)[Nozzle Data]-[Length]
(3)[Nozzle Data]-[Buffing]
High
Level
Buffing
Error
The nozzle has friction with the buffing action, or the nozzle is clogged up.
Proceed maintenance operation for the nozzle.
If nozzle don't recover good condition, recommend exchange to spare nozzle.
Even if the buffing action is smooth, when the following setting have wrong
value or it is a different setup from an actual nozzle, this error will occur.
(1)[Buffing check spec]-[Measurement height]
(2)[Nozzle Data]-[Length]
(3)[Nozzle Data]-[Buffing]
YAMAHA Motor Co. Ltd.,
IM Company
SMT Software Engineering Group
MDOC-SOFT50052
11/27
When nozzle buffing check finished normally, the [Unit] - [Head] - [Buffing check] - [Last check
information] button becomes available.
The [buffing check result] dialog can be displayed again by pushing this button. (See Fig. 4.2.5)
Use this button in such a case like you close the [buffing check result] dialog by mistake, and
also you want to see the previous result of checking. (See Fig. 4.2.3)
[Last check information] button becomes invalid if you cancel [nozzle buffing check] or power
down.
Fig. 4.2.5 Last check information
When you select [Execute all], result of a head with [ManualNzlChg] or [Fixed Nozzle]
selected on [VmSpec] - [Machine Data] - [Head] - [Head Offset] - [Head Type] is not
indicated.
YAMAHA Motor Co. Ltd.,
IM Company
SMT Software Engineering Group
MDOC-SOFT50052
12/27
When the nozzle buffing check interrupts when the nozzle buffing check is being executed
by the following causes, the error message is displayed. (See Fig. 4.2.6)
- Error occurs by the nozzle change.
- Push the emergency stop button.
- Interlock is generated.
- Error occurs by the servo.
Fig. 4.2.6 Nozzle Buffing Check Execute Error