TM3355.CheckNozzleBuffingFunctionSpecifications.pdf - 第7页
Y AMAHA M otor Co. Ltd ., IM Company SMT Software Engineering Grou p MDOC-SOFT50 052 7/27 Fig. 4.1.3 . Check exec ution confirm ation dialo g of noz zle buffi ng check. Buffing check of the selected nozzle is exec uted, …

YAMAHA Motor Co. Ltd.,
IM Company
SMT Software Engineering Group
MDOC-SOFT50052
6/27
3) Effective Nozzles of Buffing Check
[Execute all]
This can be selected only for a machine with effective nozzle station (*1).
Executes it for all nozzles that can be installed in the machine.
The heads should be set [AutoNzlChg] on [VmSpec] - [Machine Data] - [Head] –
[Head Offset] - [Head Type]
[Execute to select nozzle]
It is possible to select it any time.
Check the [Check type] check box to select nozzles, and it executes buffing check with the
selected nozzles. (Checked state is not saved)
For a machine with an invalid Nozzle Station (*2), it is possible to select one nozzle for one
head, and the nozzle is regarded as put on the head.
For a stationary nozzle, only selected nozzles on [VmSpec] – [Machine Data] – [Head] –
[Head Offset] – [Nozzle Type] are buffing checked.
[Select nozzle]
This can be selected only for a machine without Nozzle Station.
Executes buffing checking for all nozzles used with loaded board data.
Availability of nozzle buffing according to the setting of [Head Type] is explained on the next
page.
(*1) Nozzle Station is effective: setting at the [Atable], [Btable], or [ABtable] of [Nozzle Station] is
set on [VmSpec] - [Machine Information] - [Installation Setting].
(*2) Nozzle Station is invalid: setting at the [None] of [Nozzle Station] is set on [VmSpec] -
[Machine Information] - [Installation Setting].
4) When the nozzle executed here selected, and clicks on a [OK] button, the nozzle buffing
check execution confirmation dialog is displayed. (See Fig. 4.1.3)

YAMAHA Motor Co. Ltd.,
IM Company
SMT Software Engineering Group
MDOC-SOFT50052
7/27
Fig. 4.1.3. Check execution confirmation dialog of nozzle buffing check.
Buffing check of the selected nozzle is executed, when click to the [Yes].
*Availability of nozzle buffing according to the setting of [VmSpec] - [Machine Data] - [Head] -
[Head Offset] – [Head Type] is as follows.
- Nozzle Station is effective
None ManualNzlChg
AutoNzlChg Fixed Nozzle
DispenseNzl
Execute all X X O X X
Select nozzle
X O O O X
- Nozzle Station is invalid
None ManualNzlChg
AutoNzlChg Fixed Nozzle
DispenseNzl
Execute to
select nozzle
X O X O X
Select all X O X O X

YAMAHA Motor Co. Ltd.,
IM Company
SMT Software Engineering Group
MDOC-SOFT50052
8/27
4.2. Result of Checking
No abnormity found
If no abnormity is found, the following message is displayed. (See Fig. 4.2.1)
This means all checked nozzles have no problem.
Fig. 4.2.1 Nozzle buffing check finished correctly
Abnormity found
If an abnormality is found, the following message is displayed. (See Fig. 4.2.2)
Fig. 4.2.2 Abnormal nozzle was detected