TM3355.CheckNozzleBuffingFunctionSpecifications.pdf - 第8页
Y AMAHA M otor Co. Ltd ., IM Company SMT Software Engineering Grou p MDOC-SOFT50 052 8/27 4.2. Result of Che cking No abnorm ity found If no abno rmity is f ound, the f ollowing m es sage is disp layed. (See Fi g. 4.2.…

YAMAHA Motor Co. Ltd.,
IM Company
SMT Software Engineering Group
MDOC-SOFT50052
7/27
Fig. 4.1.3. Check execution confirmation dialog of nozzle buffing check.
Buffing check of the selected nozzle is executed, when click to the [Yes].
*Availability of nozzle buffing according to the setting of [VmSpec] - [Machine Data] - [Head] -
[Head Offset] – [Head Type] is as follows.
- Nozzle Station is effective
None ManualNzlChg
AutoNzlChg Fixed Nozzle
DispenseNzl
Execute all X X O X X
Select nozzle
X O O O X
- Nozzle Station is invalid
None ManualNzlChg
AutoNzlChg Fixed Nozzle
DispenseNzl
Execute to
select nozzle
X O X O X
Select all X O X O X

YAMAHA Motor Co. Ltd.,
IM Company
SMT Software Engineering Group
MDOC-SOFT50052
8/27
4.2. Result of Checking
No abnormity found
If no abnormity is found, the following message is displayed. (See Fig. 4.2.1)
This means all checked nozzles have no problem.
Fig. 4.2.1 Nozzle buffing check finished correctly
Abnormity found
If an abnormality is found, the following message is displayed. (See Fig. 4.2.2)
Fig. 4.2.2 Abnormal nozzle was detected

YAMAHA Motor Co. Ltd.,
IM Company
SMT Software Engineering Group
MDOC-SOFT50052
9/27
Click the [ERROR CLEAR] button on the error message, and the [Buffing check result]
dialog is displayed. (See Fig. 4.2.3)
Fig. 4.2.3 Buffing check result dialog
On this dialog, you can see the result of nozzle buffing check.
Moreover, since the Nozzle Station shutter is open while displaying this dialog, you can see
the abnormal nozzle condition and exchange it.
[Table No, Head No, Nozzle Type]
Table No, Head No, and Nozzle Type of all nozzles to execute nozzle buffing check
[Nozzle station No]
Nozzle Station Number corresponding to the Table No, Head No, and Nozzle Type
0 is always displayed for a manual nozzle and a stationary nozzle.
[Result]
Result of nozzle buffing check (See Table 4.2.4)
In addition, select a grid, and you can see its detail on the right area on the screen.
When the nozzle buffing check is executed for the head in which the nozzle is not set, it
becomes abnormality.