Machine Automati on Controller NX1P 12 EtherCAT Coupler Units NX-series Units on previous pages and NX-series Safety Units ca n be used by connecting to the EtherCAT Coupler Unit that is connected to the built-in EtherCA…

Machine Automation Controller NX1P
11
IO-Link Master Unit
System Units
* Use the NX-PF0730 at 4 A or less on the CPU Rack where the NX1P2 CPU Unit is mounted.
EtherNet/IP Coupler Unit
*1. One End Cover NX-END01 is provided with the EtherCAT Coupler Unit.
Product Name
Specification
Model
Number of
IO-Link ports
I/O refreshing method I/O connection terminals
IO-Link Master Unit
4
Free-Run refreshing
Screwless clamping terminal block NX-ILM400
Product Name Specification
Model
Additional NX Unit
Power Supply Unit
Power supply voltage: 24 VDC (20.4 to 28.8 VDC)
NX Bus power supply capacity: 10 W max.
NX-PD1000
Additional I/O Power
Supply Unit
Power supply voltage: 5 to 24 VDC (4.5 to 28.8 VDC)
I/O power feed maximum current: 4 A
NX-PF0630
Power supply voltage: 5 to 24 VDC (4.5 to 28.8 VDC)
I/O power feed maximum current: 10 A *
NX-PF0730
I/O Power Supply
Connection Unit
Number of I/O power terminals: IOG: 16 terminals
Current capacity of I/O power terminal: 4 A/terminal max.
NX-PC0010
Number of I/O power terminals: IOV: 16 terminals
Current capacity of I/O power terminal: 4 A/terminal max.
NX-PC0020
Number of I/O power terminals: IOV: 8 terminals, IOG: 8 terminals
Current capacity of I/O power terminal: 4 A/terminal max
NX-PC0030
Shield Connection
Unit
Number of shield terminals: 14 terminals
(The following two terminals are functional ground terminals.)
NX-TBX01
Product name Current consumption Maximum I/O power supply current Model
EtherNet/IP Coupler
Unit *
1
1.60 W or lower 10 A
NX-EIC202

Machine Automation Controller NX1P
12
EtherCAT Coupler Units
NX-series Units on previous pages and NX-series Safety Units can be used by connecting to the EtherCAT Coupler Unit that is connected to the
built-in EtherCAT port on the NX1P2 CPU Unit.
*1. One End Cover NX-END01 is provided with the EtherCAT Coupler Unit.
*2. This depends on the specifications of the EtherCAT master. For example, the values are as follows when the EtherCAT Coupler Unit is
connected to the built-in EtherCAT port on an NJ5-series CPU Unit: 500
μs, 1,000 μs, 2,000 μs, and 4,000 μs. Refer to the NJ/NX-series CPU
Unit Built-in EtherCAT Port User’ Manual (Cat. No. W505) for the specifications of the built-in EtherCAT ports on NJ/NX-series CPU Units. This
also depends on the unit configuration.
Safety CPU Units
Note: Connect the Safety CPU Unit to the NX1P2 CPU Unit via the EtherCAT Coupler Unit.
Safety Input Units
Note: Connect the Safety Input Unit to the NX1P2 CPU Unit via the EtherCAT Coupler Unit.
Safety Output Units
Note: Connect the Safety Output Unit to the NX1P2 CPU Unit via the EtherCAT Coupler Unit.
Product Name Communications cycle in DC Mode Current consumption Maximum I/O power supply current
Model
EtherCAT Coupler
Unit *1
250 to 4000 μs *2
1.45 W max.
4 A NX-ECC201
250 to 4000 μs *2
10 A
NX-ECC202
125 to 10000 μs *2 1.25 W max. NX-ECC203
Appearance
Specification
Model
Maximum number of
safety I/O points
Program capacity
Number of safety master
connections
I/O refreshing method
Unit
version
256 points 512 KB 32 Free-Run refreshing Ver.1.1 NX-SL3300
1024 points 2048 KB 128 Free-Run refreshing Ver.1.1 NX-SL3500
Appearance
Specification
Model
Number of safety
input points
Number of test
output points
Internal I/O
common
Rated
input
voltage
OMRON special
safety input
devices
Number of safety
slave
connections
I/O
refreshing
method
Unit
version
4 points 2 points
Sinking
inputs
(PNP)
24 VDC
Can be
connected.
1
Free-Run
refreshing
Ver.1.1 NX-SIH400
8 points 2 points
Sinking
inputs
(PNP)
24 VDC
Cannot be
connected.
1
Free-Run
refreshing
Ver.1.0 NX-SID800
Appearance
Specification
Model
Number of
Model safety
output points
Internal I/O
common
Maximum load current Rated voltage
Number of
safety slave
connections
I/O
refreshing
method
Unit
version
2 points
Sourcing
outputs
(PNP)
2.0 A/point, 4.0 A/Unit at 40°C,
and 2.5A/Unit at 55°C
The maximum load current
depends on the installation
orientation and ambient
temperature.
24 VDC
1
Free-Run
refreshing
Ver.1.0 NX-SOH200
4 points
Sourcing
outputs
(PNP)
0.5 A/point
and
2.0 A/Unit
24 VDC
1
Free-Run
refreshing
Ver.1.0 NX-SOD400

Machine Automation Controller NX1P
13
NX Unit Power Supply System
Add one or more NX-PF Additional I/O Power Supply Units when I/O power is supplied from the NX bus to NX Units connected to the CPU Unit.
Check the table below.
Note: Refer to the NX-series NX1P2 CPU Unit Hardware User’s Manual (Cat. No. W578) for the NX Unit power supply system.
NX Units Model
NX-PF Additional
I/O Power Supply
Unit required
Digital Input Units
NX-ID3317 Yes
NX-ID3343 Yes
NX-ID3344 Yes
NX-ID3417 Yes
NX-ID3443 Yes
NX-ID3444 Yes
NX-ID4342 Yes
NX-ID4442 Yes
NX-ID5342 Yes
NX-ID5442 Yes
NX-ID6342 Yes
NX-ID6442 Yes
NX-ID5142-1 No
NX-ID5142-5 No
NX-ID6142-5 No
NX-ID6142-6 No
NX-IA3117 No
Digital output Units
NX-OD2154 Yes
NX-OD2258 Yes
NX-OD3121 Yes
NX-OD3153 Yes
NX-OD3256 Yes
NX-OD3257 Yes
NX-OD3268 No
NX-OD4121 Yes
NX-OD4256 Yes
NX-OD5121 Yes
NX-OD5256 Yes
NX-OD6121 Yes
NX-OD6256 Yes
NX-OD5121-1 No
NX-OD5256-1 No
NX-OD5121-5 No
NX-OD5256-5 No
NX-OD6121-5 No
NX-OD6256-5 No
NX-OD6121-6 No
NX-OC2633 No
NX-OC2733 No
NX-OC4633 No
Digital Mixed I/O
Units
NX-MD6121-5 No
NX-MD6256-5 No
NX-MD6121-6 No
High-speed Analog
Input Units
NX-HAD401 Yes
NX-HAD402 Yes
Analog Input Units
NX-AD2603 Yes
NX-AD2604 No
NX-AD2608 No
NX-AD3603 Yes
NX-AD3604 No
NX-AD3608 No
NX-AD4603 Yes
NX-AD4604 No
NX-AD4608 No
NX-AD2203 Yes
NX-AD2204 No
NX-AD2208 No
NX-AD3203 Yes
NX-AD3204 No
NX Units Model
NX-PF Additional
I/O Power Supply
Unit required
Analog Input Units
NX-AD3208 No
NX-AD4203 Yes
NX-AD4204 No
NX-AD4208 No
Analog Output Units
NX-DA2603 Yes
NX-DA2605 Yes
NX-DA3603 Yes
NX-DA3605 Yes
NX-DA2203 Yes
NX-DA2205 Yes
NX-DA3203 Yes
NX-DA3205 Yes
Temperature
Control Units
NX-TC2405 Yes
NX-TC2406 Yes
NX-TC2407 Yes
NX-TC2408 Yes
NX-TC3405 Yes
NX-TC3406 Yes
NX-TC3407 Yes
NX-TC3408 Yes
Temperature Input
Units
NX-TS2101 No
NX-TS3101 No
NX-TS2102 No
NX-TS3102 No
NX-TS2104 No
NX-TS3104 No
NX-TS2201 No
NX-TS3201 No
NX-TS2202 No
NX-TS3202 No
NX-TS2204 No
NX-TS3204 No
Heater Burnout
Detection Units
NX-HB3101 Yes
NX-HB3201 Yes
Load Cell Input Unit NX-RS1201 No
Position interface:
Incremental
Encoder Input Units
NX-EC0112 Yes
NX-EC0122 Yes
NX-EC0132 Yes
NX-EC0142 Yes
NX-EC0212 Yes
NX-EC0222 Yes
Position interface:
SSI Input Units
NX-ECS112 Yes
NX-ECS212 Yes
Position interface:
Pulse Output Units
NX-PG0112 Yes
NX-PG0122 Yes
NX-PG0232-5 No
NX-PG0242-5 No
NX-PG0332-5 No
NX-PG0342-5 No
Communications
Interface Units
NX-CIF101 No
NX-CIF105 No
NX-CIF210 No
RFID Units
NX-V680C1 Yes
NX-V680C2 Yes
IO-Link Master Unit NX-ILM400 Yes