111.pdf - 第13页

Machine Automa tion Controller NX1P 13 NX Unit Power Supply System Add one or more NX-PF Additional I/O Power Supply Units when I/O power is supplied fr om the NX bus to NX Units connected to th e CPU Unit. Check the tab…

100%1 / 41
Machine Automation Controller NX1P
12
EtherCAT Coupler Units
NX-series Units on previous pages and NX-series Safety Units can be used by connecting to the EtherCAT Coupler Unit that is connected to the
built-in EtherCAT port on the NX1P2 CPU Unit.
*1. One End Cover NX-END01 is provided with the EtherCAT Coupler Unit.
*2. This depends on the specifications of the EtherCAT master. For example, the values are as follows when the EtherCAT Coupler Unit is
connected to the built-in EtherCAT port on an NJ5-series CPU Unit: 500
μs, 1,000 μs, 2,000 μs, and 4,000 μs. Refer to the NJ/NX-series CPU
Unit Built-in EtherCAT Port User’ Manual (Cat. No. W505) for the specifications of the built-in EtherCAT ports on NJ/NX-series CPU Units. This
also depends on the unit configuration.
Safety CPU Units
Note: Connect the Safety CPU Unit to the NX1P2 CPU Unit via the EtherCAT Coupler Unit.
Safety Input Units
Note: Connect the Safety Input Unit to the NX1P2 CPU Unit via the EtherCAT Coupler Unit.
Safety Output Units
Note: Connect the Safety Output Unit to the NX1P2 CPU Unit via the EtherCAT Coupler Unit.
Product Name Communications cycle in DC Mode Current consumption Maximum I/O power supply current
Model
EtherCAT Coupler
Unit *1
250 to 4000 μs *2
1.45 W max.
4 A NX-ECC201
250 to 4000 μs *2
10 A
NX-ECC202
125 to 10000 μs *2 1.25 W max. NX-ECC203
Appearance
Specification
Model
Maximum number of
safety I/O points
Program capacity
Number of safety master
connections
I/O refreshing method
Unit
version
256 points 512 KB 32 Free-Run refreshing Ver.1.1 NX-SL3300
1024 points 2048 KB 128 Free-Run refreshing Ver.1.1 NX-SL3500
Appearance
Specification
Model
Number of safety
input points
Number of test
output points
Internal I/O
common
Rated
input
voltage
OMRON special
safety input
devices
Number of safety
slave
connections
I/O
refreshing
method
Unit
version
4 points 2 points
Sinking
inputs
(PNP)
24 VDC
Can be
connected.
1
Free-Run
refreshing
Ver.1.1 NX-SIH400
8 points 2 points
Sinking
inputs
(PNP)
24 VDC
Cannot be
connected.
1
Free-Run
refreshing
Ver.1.0 NX-SID800
Appearance
Specification
Model
Number of
Model safety
output points
Internal I/O
common
Maximum load current Rated voltage
Number of
safety slave
connections
I/O
refreshing
method
Unit
version
2 points
Sourcing
outputs
(PNP)
2.0 A/point, 4.0 A/Unit at 40°C,
and 2.5A/Unit at 55°C
The maximum load current
depends on the installation
orientation and ambient
temperature.
24 VDC
1
Free-Run
refreshing
Ver.1.0 NX-SOH200
4 points
Sourcing
outputs
(PNP)
0.5 A/point
and
2.0 A/Unit
24 VDC
1
Free-Run
refreshing
Ver.1.0 NX-SOD400
Machine Automation Controller NX1P
13
NX Unit Power Supply System
Add one or more NX-PF Additional I/O Power Supply Units when I/O power is supplied from the NX bus to NX Units connected to the CPU Unit.
Check the table below.
Note: Refer to the NX-series NX1P2 CPU Unit Hardware User’s Manual (Cat. No. W578) for the NX Unit power supply system.
NX Units Model
NX-PF Additional
I/O Power Supply
Unit required
Digital Input Units
NX-ID3317 Yes
NX-ID3343 Yes
NX-ID3344 Yes
NX-ID3417 Yes
NX-ID3443 Yes
NX-ID3444 Yes
NX-ID4342 Yes
NX-ID4442 Yes
NX-ID5342 Yes
NX-ID5442 Yes
NX-ID6342 Yes
NX-ID6442 Yes
NX-ID5142-1 No
NX-ID5142-5 No
NX-ID6142-5 No
NX-ID6142-6 No
NX-IA3117 No
Digital output Units
NX-OD2154 Yes
NX-OD2258 Yes
NX-OD3121 Yes
NX-OD3153 Yes
NX-OD3256 Yes
NX-OD3257 Yes
NX-OD3268 No
NX-OD4121 Yes
NX-OD4256 Yes
NX-OD5121 Yes
NX-OD5256 Yes
NX-OD6121 Yes
NX-OD6256 Yes
NX-OD5121-1 No
NX-OD5256-1 No
NX-OD5121-5 No
NX-OD5256-5 No
NX-OD6121-5 No
NX-OD6256-5 No
NX-OD6121-6 No
NX-OC2633 No
NX-OC2733 No
NX-OC4633 No
Digital Mixed I/O
Units
NX-MD6121-5 No
NX-MD6256-5 No
NX-MD6121-6 No
High-speed Analog
Input Units
NX-HAD401 Yes
NX-HAD402 Yes
Analog Input Units
NX-AD2603 Yes
NX-AD2604 No
NX-AD2608 No
NX-AD3603 Yes
NX-AD3604 No
NX-AD3608 No
NX-AD4603 Yes
NX-AD4604 No
NX-AD4608 No
NX-AD2203 Yes
NX-AD2204 No
NX-AD2208 No
NX-AD3203 Yes
NX-AD3204 No
NX Units Model
NX-PF Additional
I/O Power Supply
Unit required
Analog Input Units
NX-AD3208 No
NX-AD4203 Yes
NX-AD4204 No
NX-AD4208 No
Analog Output Units
NX-DA2603 Yes
NX-DA2605 Yes
NX-DA3603 Yes
NX-DA3605 Yes
NX-DA2203 Yes
NX-DA2205 Yes
NX-DA3203 Yes
NX-DA3205 Yes
Temperature
Control Units
NX-TC2405 Yes
NX-TC2406 Yes
NX-TC2407 Yes
NX-TC2408 Yes
NX-TC3405 Yes
NX-TC3406 Yes
NX-TC3407 Yes
NX-TC3408 Yes
Temperature Input
Units
NX-TS2101 No
NX-TS3101 No
NX-TS2102 No
NX-TS3102 No
NX-TS2104 No
NX-TS3104 No
NX-TS2201 No
NX-TS3201 No
NX-TS2202 No
NX-TS3202 No
NX-TS2204 No
NX-TS3204 No
Heater Burnout
Detection Units
NX-HB3101 Yes
NX-HB3201 Yes
Load Cell Input Unit NX-RS1201 No
Position interface:
Incremental
Encoder Input Units
NX-EC0112 Yes
NX-EC0122 Yes
NX-EC0132 Yes
NX-EC0142 Yes
NX-EC0212 Yes
NX-EC0222 Yes
Position interface:
SSI Input Units
NX-ECS112 Yes
NX-ECS212 Yes
Position interface:
Pulse Output Units
NX-PG0112 Yes
NX-PG0122 Yes
NX-PG0232-5 No
NX-PG0242-5 No
NX-PG0332-5 No
NX-PG0342-5 No
Communications
Interface Units
NX-CIF101 No
NX-CIF105 No
NX-CIF210 No
RFID Units
NX-V680C1 Yes
NX-V680C2 Yes
IO-Link Master Unit NX-ILM400 Yes
Machine Automation Controller NX1P
14
Automation Software Sysmac Studio
The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine
automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI.
For details, refer to your local OMRON website and Sysmac Studio Catalog (Cat. No. P138).
Collection of software functional components Sysmac Library
Please download it from following URL and install to Sysmac Studio.
https://www.ia.omron.com/sysmac_library/
Typical Models
Product Features Model
Vibration Suppression Library
The Vibration Suppression Library is used to suppress residual vibration caused by the operation of
machines.
SYSMAC-XR006
Device Operation Monitor Library
The Device Operation Monitor Library is used to monitor the operation of devices such as air cylinders,
sensors, motors, and other devices.
SYSMAC-XR008
Dimension Measurement Library
The Dimension Measurement Library is used to dimension measurement with ZW-8000/7000/5000
Confocal Fiber Displacement Sensor, or E9NC-TA0 Contact-Type Smart Sensor.
SYSMAC-XR014