SIPLACE Pro 15.1 (R18-1) / Version Description 05/2018 Edition
19
5.4 Line Configuration with Inspection Systems and AOI Devices
Inspection Systems have been added to the Devices of Line Tree View in the Line Editor. Here
the user can create solder paste inspection devices. Currently, only ASM Process Lens is
supported. IP address, host name and software version can be edited.
The Custom generic line device has been extended by two new attributes: Manufacturer (name of
the manufacturer of the device) and Equipment ID (Id of the machine / serial number).
The existing generic line device type, containing Undefined and AOI has been extended by the
following new types:
AOXI, AXI, ClassificationArea, RepairArea, PlacementMachine, Printer, SPI, Oven.
5.5 New Placement Force Very Low Force in Placement, Pickup and
Dipping Processes
The new very low force state has been added to SIPLACE Pro.
In the Handling tab of the Component Shape Editor, the force state for placement, pick-up and
dipping can be set in a drop-down menu:
Standard: the standard force is used.
Manual: the user can enter own values.
Very low: the very low force state is enabled.
The very low force state can only be used for the following placement heads:
C&P20 M2, C&P20 P and (from R18-1) C&P20 P2.
5.6 SEMO CRF80New Tape Feeder
The new SEMO CRF80 tape feeder from the SEMO company is supported by SIPLACE Pro and
occupies seven tracks on the X-table. The feeder is distributed directly by the manufacturer.
5.7 External Barcode Reader in the Middle of the Line
External barcode readers can now be used in front of any placement machine in the line together
with the Board Gate Keeper. The Board Gate Keeper can be defined as preceding whisperer of
any station, e.g. the third station in the line.
Example:
The line consists of three placement machines. In front of the line and between the second and
third station there is a conveyor with an integrated board barcode reader. These readers shall
be used for traceability purposes and be connected with Traceability via the Board Gate
Keeper.
If the Board Gate Keeper shall be configured as preceding whisperer for both the first and the third
station, the Use station Setting has to be set in the Setup Editor for the line.
SIPLACE Pro 15.1 (R18-1) / Version Description 05/2018 Edition
20
Additionally, the External Board Barcode option has to be set in the respective station setup of
the first and the third station to define that the board barcodes shall be whispered from external (=
from the Board Gate Keeper on the line computer). Only external inkspots, panel fiducials and
(external) virtual inkspots can be whispered from the Board Gate Keeper to the first and the third
station.
The station software only supports one preceding whisperer. The Board Gate Keeper is then the
only preceding whisperer of the e.g. third station. Therefore, the (internal) inkspots and panel
fiducials, read by the first station, cannot be whispered e.g. from the second to the third station (via
the barcode transferred from the Board Gate Keeper to the third station).The third station has to re-
read all (internal) inkspots and panel fiducials again.
5.8 Barcode Conditions for Traceability Purposes
When reading the barcode with the board camera for traceability purposes, the Vision system shall
verify that the recognized barcode is the correct one to be used for traceability.
To avoid that an incorrect barcode is read, the user can define conditions for the barcode in the
Vision system at the station. If a barcode does not fulfill all conditions, the Vision system looks for
another barcode with valid conditions in the region of interest. The conditions are saved in the
Barcode Fiducial in SIPLACE Pro.
SIPLACE Pro Line Control sends the data to stations running station software version 711.The
data can be taught at the station and saved back into SIPLACE Pro. The barcode data cannot be
edited in SIPLACE Pro but deleted in the Fiducial Editor by pressing the Remove all vision data
button.
5.9 BOM-Merger: Automatic Component Shape Linking
The BOM Merger can create components in SIPLACE Pro although they are not yet available in
the database. The BOM Merger has been extended to automatically assign the component shape
of the component at existing component placements to the newly created component in the BOM
file.
The BOM Merger links newly created components to the already existing component shape which
is referenced by the current component of the original component placement. Components that
already exist and for which there is no reference to a component shape will also be automatically
linked to the component shape of the original component in the placement list. Conversely, existing
components which do reference a component shape will be unchanged.
Existing alternative component shapes assigned to the original component will also be transferred
to the target component. No other attributes of the original component will be transferred.
SIPLACE Pro 15.1 (R18-1) / Version Description 05/2018 Edition
21
6 Restrictions
In the following, existing restrictions in SIPLACE Pro are described.
Miscellaneous
10-fold and 15-fold stick magazines cannot be combined on the same linear feeder.
SIPLACE Pro object names (e.g., recipe) must not exceed 125 ASCII characters (including
folder names).
If various users optimize the same job at the same time, the job which was most recently
completed successfully will overwrite all corresponding recipes.
The board panel hierarchy must not exceed 10 levels.
The object folder hierarchy must not exceed 10 levels.
The operator must manually place manual tray carriers (Carrier 30, Carrier 51, Carrier X,
Carrier SX, Arbitrary Carrier), glue feeders, dip modules, reject conveyors and power
connectors in the initial setup.
If you work with reduced acceleration for a component shape, this is seen as a "special case"
and the accuracy of 5% for the simulated Optimizer production time will not be achieved.
The Optimizer does not check if the tray size is bigger than the carrier.
The WPC can take up to 10 different component types per level. This restriction does not apply
for machines from station software version 7xx.
Station-wise Download
It is not possible to switch over from dual lane conveyor in asynchronous transport mode to
dual lane conveyor in synchronous transport mode (and vice versa) in combination with station-
wise download.
When the line control server is rebooted, station-wise downloading will be canceled. After
rebooting, you will need to perform a complete line download to restart production.
Station-wise downloading supports setup changes in asynchronous dual operation only when
you have the same definition for both lanes.
Station-wise downloading supports synchronous dual operation as of station software version
704.
ASCII Centroid Import
If component shapes are selected in the ASCII Centroid Import Wizard, all the existing links
between components and component shapes will be overwritten with the imported information.