SQUEEGEE MODULE
REPLACEMENT PROCEDURES
9.14 Technical Reference Manual Chapter Issue 6, Jul 16
6. Fit the front squeegee to the front squeegee mount ensuring the thumb-
screws are tightened finger tight.
NOTE
The locking thumbscrews on the front squeegee are positioned closer
together than those fitted to the rear squeegee and the keyway slot is
positioned on the right hand side of the front squeegee.
7. Close the front printhead cover.
8. Press the System button.
9. Select Continue.
10. Select Back.
11. Carry out Squeegee Reference Height calibration, Calibrations section of
this chapter refers.
SQUEEGEE MODULE
CALIBRATIONS
Chapter Issue 6, Jul 16 Technical Reference Manual 9.15
CALIBRATIONS
Squeegee
Pressure
Calibration
Squeegee pressure calibration is carried out on machines, fitted with the
Pressure Hardware option, after the following circumstances:
The squeegee mechanism is replaced
The strain gauge bridge in the squeegee mechanism is replaced
The rising table sensors have been replaced or adjusted
A force meter calibration jig and squeegee pressure plate are required to
perform the squeegee pressure calibration.
NOTE
1. Ensure that the rising table print reference height is set correctly before
commencing, (the calibration relies upon accurate positioning of the table to
make a reference).
2. Ensure that the Pressure Hardware parameter in Maintenance\Machine
Setup\Options is set to FITTED.
Use the following procedure to calibrate the squeegee pressure:
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
1. Select Open Cover Commands.
2. Select Carriage To Rear.
3. Select Unload Screen.
4. Open the front printhead cover.
5. Remove the stencil from the machine.
6. Remove the tooling from the manual tooling plate.
7. Close the front printhead cover.
8. Press the System button.
9. Select Back.
10. Select Maintenance.
11. Select Calibrations.
12. Select Pressure.
13. Select Calibrat Readings.
The rails are checked for the presence of a board, the print carriage moves
to the calibration position, the rear rail moves to home position, the table
homes and the board clamps are closed.
14. The machine cover is unlocked and the message ‘Fit the pressure calibra-
tion rig’ is displayed with the following window:
CALIBRATION DATA
Gain Factor
1.02
SQUEEGEE MODULE
CALIBRATIONS
9.16 Technical Reference Manual Chapter Issue 6, Jul 16
15. Open the front printhead cover.
16. Ensure that the calibration jig is secured to the mounting plate as shown in
the following graphic:
Mounting Plate
Mounting Holes
Calibration Jig
A
A
S