PatternPro Variable Pitch Guns.pdf - 第27页

23 P/N 1048257_03  2018 Nordson Corporation PatternPro Edition 02/18 Flushing the Applicator Before operating the system, the applicator must be flushed to remove residue left over from factory‐testing. Install the nozz…

100%1 / 54
22
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Connecting the Hose
Refer to the user's guide shipped with the hose for detailed hose installation
guidelines.
1. Do one of the following:
If an in‐line filter is to be used, remove the hose connector
preinstalled on the applicator and then install the in‐line filter. Refer to
the instruction sheet provided with the in‐line filter.
If no in‐line filter is used, check the tightness of the preinstalled hose
connector.
See Figure 7.
2. Connect the hose swivel fitting to the applicator hose connector. Use two
wrenches to tighten the hose fitting.
3. Connect the applicator cordset to the hose.
4. Connect the hose to the melter. Refer to the hose user's guide and/or the
melter product manual as needed.
5. Go to Flushing the applicator.
1
2
Fig. 7 Connecting the Hose to the applicator
1 Tightening the hose‐to‐applicator
fitting
2 Plugging in the cordset
23
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Flushing the Applicator
Before operating the system, the applicator must be flushed to remove
residue left over from factory‐testing. Install the nozzles after this procedure.
For information on installing nozzles, refer to Maintenance.
NOTE: This equipment is factory tested with Nordson Type R fluid
containing polyester adipate plasticizer. Certain adhesives may react with the
Type R fluid residue to form a solid gum that can be difficult to remove.
Consult with the adhesive supplier to determine the compatibility of the
adhesive with Type R fluid.
1. Disconnect or turn off the solenoid valve triggering device.
2. Turn on the melter and allow it to reach operating temperature. Refer to
the melter manual for the startup procedure.
3. Place a drain pan under all applicators.
4. Flush according to the type of applicator module being used:
For standard Applicators
a. Dispense hot melt material from the applicator by manually triggering
the solenoid valve(s).
b. Stop dispensing when the flow of hot melt material is clear and free of
residue.
24
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
For all Applicators except zero and reduced cavity applicators
a. Ensure that all nozzles are removed.
b. Dispense hot melt material from the applicator by manually triggering
the solenoid valve(s).
c. Stop dispensing when the flow of hot melt material is clear and free of
residue.
For zero and reduced cavity Applicators
a. Relieve system hydraulic pressure and disable the applicator. Refer
to Safety.
b. Remove the applicator module by removing the two mounting screws
from the front of the module.
c. Re‐pressurize the system; then place the applicator into operation.
d. Dispense hot melt material from the port(s) in the applicator body,
increasing the pump output in small increments.
e. Stop dispensing when the hot melt material is clear and free of
residue.
5. Check for leaks between the applicator, hose, and melter.
6. Do one of the following:
Continue to the next procedure, Pivoting the applicator Modules.
Install the nozzles, refer to Maintenance.