26 P/N 1048257_03 2018 Nordson Corporation PatternPro Edition 02/18 Operation The applicator is now ready for operation. Starting the System Follow this procedure to start the system. CAUTION: Risk of equipment damage.…

1
2
25
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Pivoting the Applicator Modules
Before operating the system, pivot the applicator module to the required
position for application of variable pitch patterns.
NOTE: The applicators have typically pivot marks on the rotating disk that
are spaced in increments of 5. The reference marks are also provided on
the rotating disk.
1. Relieve the system hydraulic pressure. Refer to Safety.
1 Pivot marks
2 Reference marks
Fig. 8 Marks on the MiniBlue ll applicators
CAUTION: Do not pivot the the applicator modules if the applicator is cold.
Pivoting the applicator modules when the applicator is not heated will
damage the O‐rings.
Fig. 9
WARNING: System pressurized! Relieve system pressure before adjusting
the applicator. Failure to relieve system pressure can result in personal
injury.
2. Loosen the two hexagon head screws located on the back of the
applicator body.
3. Pivot the applicator modules to the desired position.
4. Tighten the hexagon head screws.

26
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Operation
The applicator is now ready for operation.
Starting the System
Follow this procedure to start the system.
CAUTION: Risk of equipment damage. Nordson Corporation recommends
turning off the applicator air supply during system startup to prevent
unexpected pressure buildup in the module and applicator body caused by
the expansion of the cold adhesive as it melts.
1. Make sure the applicator air supply is turned off.
2. Turn on the melter and allow it to reach operating temperature. Refer to
your melter manual for details on the startup procedure.
3. Turn on the applicator air supply.
4. Turn on the solenoid valve power supply, enable any triggering devices,
and start the production line.

27
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Shutting the System Down
Follow this procedure to shut down the system.
1. Stop the production line.
WARNING: System or material pressurized. Relieve pressure. Failure to
observe this warning may result in serious injury.
2. Turn off the pump and relieve hydraulic pressure. Refer to your melter
manual.
3. Turn off the melter. Refer to your melter manual for details on the system
shut down procedure.
WARNING: Hot! Risk of burns. Wear heat‐protective clothing, safety
goggles, and heat‐protective gloves.
4. Place a drain pan under all applicators.
5. Manually trigger the applicators until they are drained of hot melt material.
6. Turn off the solenoid valve power supply.
7. Turn off the applicator air supply.
8. Manually trigger the applicator solenoid valves to relieve applicator air
pressure.