PatternPro Variable Pitch Guns.pdf - 第38页

34 P/N 1048257_03  2018 Nordson Corporation PatternPro Edition 02/18 Diagnostic Procedures (DPs) The following diagnostic procedures (DPs) are referenced in the Troubleshooting Table . DP1. Check a Solenoid Valve 1. Pla…

100%1 / 54
33
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Troubleshooting Table (contd)
Table 5 Troublehooting Table
(contd)
Problem Possible Cause Corrective Action
5. Modules not
triggering at the
same time on
multi‐module
applicator
Applicator module adjustment
screw not properly set (all
applicators except MiniBluell)
Contact Nordson technical support.
Module failed Replace the O‐ring. Refer to Replacing the
Rotating Disk and applicator Module in Repair.
Insufficient applicator air
pressure
Increase the applicator air pressure.
6. Applicator fails to
heat or underheats
No power Check that the melter is on. Refer to the melter
manual.
Applicator temperature setting
too low
Adjust the temperature setting. Refer to the
melter manual.
Applicator heater failed (open
or short)
Check for an open heater circuit. Refer to DP4.
Applicator RTD failed (open or
short)
Check the RTD resistance. Refer to DP4.
7. Applicator
overheats
Melter, hose, or applicator
temperature setting too high
Adjust the setting. Refer to the melter manual.
Applicator RTD shorted
(melter should shut down)
Check the RTD resistance. Refer to DP4.
Short in heater control circuit Troubleshoot the melter. Refer to the melter
manual.
34
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Diagnostic Procedures (DPs)
The following diagnostic procedures (DPs) are referenced in the
Troubleshooting Table.
DP1. Check a Solenoid Valve
1. Place the system into operation.
2. Trigger the applicator using the timer or pattern controller:
Hot melt material flows—normal indication. Return to the
Troubleshooting Table.
Hot melt material does not flow—go to step 3.
3. Manually trigger the applicator at the solenoid valve:
Hot melt material flows—normal indication. Return to the
Troubleshooting Table.
Hot melt material does not flow—go to step 4.
4. Check the solenoid valve coil for continuity:
Continuity okay—normal indication. Return to the Troubleshooting
Table.
No continuity—failed solenoid valve. Replace the solenoid valve.
Refer to Connecting the Solenoid Valve.
NOTE: Verify that the solenoid valve being used has a rated service
temperature above 85 C (185 F).
35
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
DP2. Check for a Clogged Nozzle or Module
1. Disable the applicator. Refer to Safety.
2. Remove the nozzle. Refer to Cleaning Nozzles in Maintenance for the
nozzle‐removal procedure.
3. Place the applicator back into operation.
4. Trigger the applicator:
Hot melt material flows—normal indication. Clean the nozzle. Refer to
Cleaning the Nozzles in Maintenance.
Hot melt material does not flow—the module is clogged. Replace the
module. Refer to Replacing the Rotating Disk and applicator Module
in Repair.
DP3. Check a Heater
1. Disable the applicator. Refer to Safety.
2. Unplug the applicator cordset from the hose.
3. See Figure 10. Test for continuity across the heater circuit (pins 1 and2):
Continuity okay—normal indication. Return to the Troubleshooting
Table.
No continuity—the heater is defective. Replace the heater. Refer to
Replacing a RTD or Heater in Repair.
4209011A
1
2
3
4
5
6
1
2
3
5
HEATER
HEATER
RTD
RTD
GND
4
12
34
5
Fig. 10 Applicator Cordset Pins