PatternPro Variable Pitch Guns.pdf - 第44页
40 P/N 1048257_03 2018 Nordson Corporation PatternPro Edition 02/18 Replacing the Rotating Disk and Applicator Module WARNING: System or material pressurized. Relieve pressure. Failure to observe this warning may resul…

39
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Replacing a RTD or Heater (contd)
To replace the RTD
a. Disconnect the ground lead from the applicator body and remove the
cordset.
b. Install a new cordset and insert the RTD in the applicator body by
tightening the screws.
c. Reconnect the ground lead to the applicator body.
To replace the heater
a. If necessary, trim the leads of the new heater to match the leads of
the old heater.
b. Insert the heater in the applicator body.
c. Insert each heater lead into the terminal block and tighten the terminal
block screws.
d. Insert the heater leads from the cordset into the terminal block and
tighten the terminal block screws.
8. Check the internal applicator wiring for signs of damage and the terminal
block connections for tightness.
9. Reinstall the applicator body cover, by reinstalling and tightening the four
Allen head screws.
10. If the hose was removed earlier, use two wrenches to connect the hose to
the applicator.
11. Plug the applicator cordset into the hose.
12. Restore the system to normal operation.

40
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Replacing the Rotating Disk and Applicator Module
WARNING: System or material pressurized. Relieve pressure. Failure to
observe this warning may result in serious injury.
1. De‐energize the system and relieve system pressure. Refer to Safety.
2. Place a drain pan under the nozzles and trigger the applicator modules to
relieve any system pressure which may have accumulated.
3. If applicable, remove the nozzle from the applicator module.
See Figure 13.
4. Loosen the two hexagon head screws located on the back of the
applicator body to remove rotating disk with O‐rings, and applicator
module
2
7
1
8659493
Fig. 13 Replacing the Rotating Disk and applicator Modules
1 Hexagon head screws
2 Applicator body
3 Disk cavity
4 O‐rings
5 O‐rings
6 Rotating disks
7 Mounting screws
8 Applicator modules
9 Back up rings

41
P/N 1048257_03
2018 Nordson Corporation
PatternPro
Edition 02/18
Replacing the Rotating Disk and Applicator Module (contd)
CAUTION: Specific to MiniBlue II, and ClassicBlue applicators.
Do not allow hot melt material to enter the module air passages. Adhesive in
the air passages will obstruct the flow of air and damage the module. If hot
melt material enters the air passages, temporarily place the applicator into
operation, shield the operator, and then trigger the applicator to expel the hot
melt from the air passages.
5. Carefully remove any residual hot melt material from the module, rotating
disk, and the disk cavities.
6. Install the new O‐rings. Lubricate the O‐rings and rotating disk with
heat‐resisting lubricant. Check the position of the back up rings(1.)
relative to the o-rings (2) carefully.
12 21
Fig. 14 Position of O-and back up rings.
7. Apply anti‐seize compound to the module mounting screws, then install
the module on the applicator body.
8. Reattach the mounting screws. Tighten to 3.4 Nm (30 in.‐lb).
9. Tighten the hexagon head screws.
10. If applicable, install the old nozzle or a new replacement nozzle. Tighten
the nozzle to 4.5 Nm (40 in.‐lb).
11. If the hose was removed earlier, use two wrenches to connect the hose to
the applicator.
12. Plug the applicator cordset into the hose.
13. Restore the system to normal operation.