Station S oftware 71 0.0 (R16 - 2) / Version Descript ion 12/2016 Edition 27 8 Corrected Error s 710.0 Station Software The 710.0 s tation sof tware versio n contai ns all error c orrections of the pre vious 701.x – 709.…
Station Software 710.0 (R16-2) / Version Description 12/2016 Edition
26
7 Restrictions
For details concerning possible machine configurations, please consult the latest version of the
machine specification.
Restrictions to features in previous versions can be found in the Station Software V7xx Feature
Description, item no. [00197741-xx].

Station Software 710.0 (R16-2) / Version Description 12/2016 Edition
27
8 Corrected Errors
710.0 Station Software
The 710.0 station software version contains all error corrections of the previous 701.x – 709.x
versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-125536301 Sorting by track did not function in the Vision dumps.
D1-127573107 Table fiducials could not be measured.
D1-128067060 The plate shutter of the BulkFeeder X was open when the machine was
running and the board fully assembled.
D1-128067411 Sporadically, the BulkFeeder X hung up with 38513 Plate or container
shutter: Error
.
D1-128970072 All four gantries should go to the SPS service position. This failed as a
collision was reported.
D1-129741201 Zero point correction could not be set at the DLM4 star axis.
D1-129804680 Test function Cut could not be repeated.
D1-129883901 Barcode could not be read together with conveyor.
D1-131846701 The station software stopped with an error message during production.
Table 8-1: Corrected errors station software version 710.0
709.1 SP2 Hotfix 1
Error no. Error description
D1-122679801 eSW: SIPLACE SmartFeeder 8mm X: wrong pickup position.
D1-129993001 The cameras were not recognized and BIOS was loaded from the RAM
instead of using the latest version.
D1-130250709 The used component shape seemed to be corrupt (the travel profile was not
correct).
D1-131408001
D1-131824889
eSW: sporadically the mapping data of the Y axis (gantry 2) were not used
respectively there was a problem when the cover was opened and gantry 1
was pushed too close to gantry 2.
D1-131788001 eSW: the download of the embedded software for the TSP420 conveyor did
not work.
D1-131824301 Missing error message in trace files when placement positions were skipped
by the operator.
D1-131877158
D1-133757001
When a waiting time for placement of 250 ms was defined or when a
component should be placed with a high force (>= 30N), the software hung up
with error message:
30016 Unhandled exception error
.

Station Software 710.0 (R16-2) / Version Description 12/2016 Edition
28
D1-131921801 If a program with an incomplete component shape and a placement position
that had to be taught was downloaded, the machine started with the teaching
of the placement position even though the component shape had not been
taught.
D1-131949317 After a placement with 70N the machine stopped without error message.
D1-132005405 eSW: error message 30560 Could not detect that the valves on
the valve terminal closed led to a software hang-up.
D1-132028101
D1-131880701
D1-131929707
D1-131985201
D1-132028173
D1-132541001
eSW: the machine stopped with error message 40023 CAUTION: Do not
move gantry! Segment is down.
D1-132146101 eSW: during dry run the machine stopped with error message 40020
Unknown placement state.
D1-132430801 During production, the error 32602 The software has stopped
unexpectedly. Shut down Windows, then restart the station.
occurred.
D1-132508593 Could not calibrate the chuck fiducial position.
D1-132542701 The machine stopped with error message 32590 Possible collisions
with high components
.
D1-132564701 Although the manual barcode input was deactivated in SIPLACE Pro, it was
still allowed at the station.
D1-132595901 The "single component tracking" for the SWS did not write the board barcode
into the trace file.
D1-132598506 After having opened one cover to change the reel, the machine did not start
again.
D1-132650401 The GUI hung up after a JTG hardware problem.
D1-133060801 Calibrating processing area 2 led to error message 33450 cannot move
calibration plate
.
D1-133198601 The picture to control the defect position was not displayed when a yellow
board was reported.
D1-133227101 When a component should be picked up by the Twin head, the error message
30341 Position is out of range
occurred.
D1-133265101 Error messages 42416 Move plausibility failure and 42419
Invalid time stamps error
were displayed.
D1-133678341 The board view did not display the placement position anymore.
D17845-11307 The machine could not pick up components from the feeder during normal
production.
D18149-4401
D18149-4501
During production the machine stopped sometimes but the GUI still displayed
production status and no error message.
D18171-10932 Both signal lamps were flashing when there was a track error on one table.
Table 8-2: Corrected errors station software 709.1 SP2 Hotfix 1