252301 Issue 2.0.pdf - 第113页

GEM Manual for DEK Printers Equipment Va riables I ssue 2.0 June 9th, 2011 page 113 of 156 7.4.1 Limit List The L imit Set Values are he ld in a list that is structured as follows: <L imit List> : Structure: L , m …

100%1 / 156
GEM Manual for DEK Printers Equipment Variables
Issue 2.0 June 9th, 2011 page 112 of 156
Name DVID
Limits
Monitor
Description Type Value Range
screen_fiducial_2_score 2025 Yes The acceptance score of screen
fiducial 2.
U4 0-1000
screen_fiducial_3_score 2026 Yes The acceptance score of screen
fiducial 3.
3 fiducial mode must be selected.
U4 0-1000
LimitVariable 2027 No This variable contains the VID for
the variable whose value changed
monitoring zones.
U4 See list of VID’s for limits
monitoring.
EventLimit 2028 No This variable contains the LIMITID
of the limit reached or crossed by
LimitVariable. Since multiple zone
transitions for a variable may occur
simultaneously, EventLimit has
been defined to allow for a list of
LIMITIDs.
List of
U1
1-7
TransitionType 2029 No This variable defines the direction
of the zone transition that has
occurred.
B
1 byte
0 = Transition from lower
zone to upper zone.
1 = Transition from upper
zone to lower zone.
RemoteBarCode 2030 No Product bar code string provided by
the serial bar code reader.
The default is “NO CODE”.
A32 Up to a 32 character string.
The actual length is
determined by the barcode.
ProflowPastePressure 2031 Yes Actual Paste Pressure used by the
Proflow paste mechanism.
F8 0-20 Kg
Reserved 2032 No Not used by the 265.
Traceability Data 2033 No List of traceability data for the last
processed product.
Variabl
e
See <Traceability Data>
Failed verification item 2034 No List of the items that last failed
verification
Variabl
e
See <Failed Verification
Items>
Reserved 2083 No
Reserved 2084 No
Reserved 2085 No Not used.
front_print_speed 2086 Yes
Speed measured during the last front
print stroke.
F8 2-150 mm/s
rear_print_speed 2087 Yes Speed measured during the last rear
print stroke.
F8 2-150 mm/s
Modified Parameters 2088 No
This variable contains the parameter
ID, name, old value and new value
for the parameters whose value
changed at instrument.
Modifi
ed
Parame
ter List
See <Modified Parameter
List>
GEM Manual for DEK Printers Equipment Variables
Issue 2.0 June 9th, 2011 page 113 of 156
7.4.1 Limit List
The Limit Set Values are held in a list that is structured as follows:
<Limit List>
:
Structure: L, m ; m = Number of Limit sets
; with SPC output enabled.
1. L, 28 ; First Limit Set
1. Limit Blockage Ave ;Type F4
2. Limit Blockage Max ;Type F4
3. Limit blockage Max Site ID ;Type A20
4. Limit Blockage Min ;Type F4
5. Limit blockage Max Site ID ;Type A20
6. Limit Paste Ave ;Type F4
7. Limit Paste Max ;Type F4
8. Limit paste Max Site ID ;Type A20
9. Limit Paste Min ;Type F4
10. Limit paste Min Site ID ;Type A20
11. Limit Volume Ave ;Type F4
12. Limit Volume Max ;Type F4
13. Limit volume Max Site ID ;Type A20
14. Limit Volume Min ;Type F4
15. Limit volume Min Site ID ;Type A20
16. Limit Print X Ave ;Type F8
17. Limit Print X Max ;Type F8
18. Limit print X Max Site ID ;Type A20
19. Limit Print X Min ;Type F8
20. Limit print X Min Site ID ;Type A20
21. Limit Print Y Ave ;Type F8
22. Limit Print Y Max ;Type F8
23. Limit print Y Max Site ID ;Type A20
24. Limit Print Y Min ;Type F8
25. Limit print Y Min Site ID ;Type A20
26. Limit Smear ;Type F8
27. Limit Bridging ;Type F8
28. Limit ID ;Type A20
.
. ; all elements of the list are identically
m. ; structured
GEM Manual for DEK Printers Equipment Variables
Issue 2.0 June 9th, 2011 page 114 of 156
The items in the list are as follows:
No. Item Limits
Monitor
Description Type Range
1 Limit Blockage Ave Yes Stencil average percentage aperture blockage
for limit set.
F4 0-100 %
2 Limit Blockage Max Yes
Stencil maximum percentage aperture blockage
for limit set.
F4 0-100 %
3 Limit Blockage Max Site ID
No
Site ID that generated the maximum blockage
for limit set.
A20 Up to 20
characters max.
4 Limit Blockage Min Yes Stencil minimum percentage aperture blockage
for limit set.
F4 0-100 %
5 Limit Blockage Max Site ID
No
Site ID that generated the minimum blockage
for limit set.
A20 Up to 20
characters max.
6 Limit Paste Ave Yes Average paste present for limit set. F4 0-100 %
7 Limit Paste Max Yes Maximum paste present for limit set. F4 0-100 %
8 Limit Paste Max Site ID
No
Site ID that generated the maximum paste
present for limit set.
A20 Up to 20
characters max.
9 Limit Paste Min Yes Minimum paste present for limit set. F4 0-100 %
10 Limit Paste Min Site ID
No
Site ID that generated the minimum paste
present for limit set.
A20 Up to 20
characters max.
11 Limit Volume Ave Yes Average paste volume for limit set. F4 0-100 %
12 Limit Volume Max Yes Maximum paste volume for limit set. F4 0-100 %
13 Limit Volume Max Site ID
No
Site ID that generated the maximum volume for
limit set.
A20 Up to 20
characters max.
14 Limit Volume Min Yes Minimum paste volume for limit set. F4 0-100%
15 Limit Volume Min Site ID
No
Site ID that generated the minimum volume for
limit set.
A20 Up to 20
characters max.
16 Limit Print X Ave Yes Average paste-pad X error for limit set. F8
±1 mm
17 Limit Print X Max Yes Maximum paste-pad X error for limit set. F8
±1 mm
18 Limit Print X Max Site ID
No
Site ID that generated the maximum X error for
limit set.
A20 Up to 20
characters max.
19 Limit Print X Min Yes Minimum paste-pad X error for limit set. F8
±1 mm
20 Limit Print X Min Site ID
No
Site ID that generated the minimum X e
rror for
limit set.
A20 Up to 20
characters max.
21 Limit Print Y Ave Yes Average paste-pad Y error for limit set. F8
±1 mm
22 Limit Print Y Max Yes Maximum paste-pad Y error for limit set. F8
±1 mm
23 Limit Print Y Max Site ID
No
Site ID that generated
the maximum Y error for
limit set.
A20 Up to 20
characters max.
24 Limit Print Y Min Yes Minimum paste-pad Y error for limit set. F8
±1 mm
25 Limit Print Y Min Site ID
No
Site ID that generated the minimum Y error for
limit set.
A20 Up o 20
characters max.
26 Limit Smear Yes Stencil paste smear area for limit set. F8
±5 sq. mm
27 Limit Bridging Yes Board pad bridging for limit set. F8
±1 mm
28 Limit ID
No
The limit set name. A20 Up to 20
characters max.
Exception: A zero length list m = 0 indicates that no limit sets are enabled for SPC output.
7.4.2 Modified Parameter List
The Modified Parameter list is structured as follows:
<Modified Parameter List>:
Structure: L, m ; m = Number of Modified Parameter list
1. L,4