252301 Issue 2.0.pdf - 第90页
GEM Manual for DEK Printers SECS II Implementation I ssue 2.0 June 9th, 2011 page 90 of 156 S6F23 Request Spooled Data (RSD) S6F24 Request Spooled Data (RSDA S) Description: The purpose of this message is for the host to…
GEM Manual for DEK Printers SECS II Implementation
Issue 2.0 June 9th, 2011 page 89 of 156
S6F15 Event Report Request (ERR)
S6F16 Event Report Data (ERD)
Description: The host can use this transaction to demand a specified report group from
the equipment. Note that discrete data variables will have indeterminate values.
A. Host Initiated
Host to equipment: S6F15
Structure: <CEID>
Equipment to host: S6F16
Structure: Identical to S6F11.
Exception: A zero length list indicates there are no reports linked to the
specified CEID.
B. Equipment Initiated - Not applicable.
S6F19 Individual Report Request (IRR)
S6F20 Individual Report Data (IRD)
Description: The host can request a defined report to send. The report does not have to
be linked to a CEID, therefore no CEID are required to be enabled.
A. Host Initiated
Host to equipment: S6F19
Structure: <RPTID>
Equipment to host: S6F20
Structure: L,n ; n = No. of variable data items
1.<V1>
.
.
n. <Vn>
Exception: If n = 0 then the report RPTID does not exist.
B. Equipment Initiated - Not applicable.
GEM Manual for DEK Printers SECS II Implementation
Issue 2.0 June 9th, 2011 page 90 of 156
S6F23 Request Spooled Data (RSD)
S6F24 Request Spooled Data (RSDAS)
Description: The purpose of this message is for the host to request transmission or
deletion of the messages currently spooled by the equipment.
A. Host Initiated
Host to equipment: S6F23
Structure: <RSDC>
Equipment to host: S6F24
Structure: <RSDA>
B. Equipment Initiated - Not applicable.

GEM Manual for DEK Printers SECS II Implementation
Issue 2.0 June 9th, 2011 page 91 of 156
6.7 STREAM 7: PROCESS PROGRAM MANAGEMENT
S7F1 Process Program Load Inquire (PPI)
S7F2 Process Program Load Grant (PPG)
Description: This message is used to initiate the transfer of a process program. It’s use,
by the host, is optional.
A. Host Initiated
Host to equipment: S7F1
Structure: L,2
1. <PPID>
2. <LENGTH>
Equipment to host: S7F2
Structure: <PPGNT>
Exception: If LENGTH = 0 or different format then the LENGTH will be
ignored.
B. Equipment Initiated
Equipment to host: S7F1
Structure: L,2
1. <PPID>
2. <LENGTH>
Host to equipment: S7F2
Structure: <PPGNT>