2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) S IPLACE S-25 HM 2.4 Sequence: Inst alling the Hardware 02/01 Issue 60 .H\ 1. V elcro- type f astener under the ribbon c ables ( 3 cables …

SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen)
02/01 Issue 2.4 Sequence: Installing the Hardware
59
,QVWDOOLQJ1HZ6HJPHQW5HYROYHU+HDG59'/0
.H\
1. 4 silicone hoses, connection to silencer and vacuum generator
2. Vacuum generators with silencers are still dismantled at this point.
3. Push placement head on.
4. Re-use 2 wide ribbon cables from the de-installed head.
(Do this with ribbon cable "Illumination board" also -> see: Fig. 2.4.1)
Å The silencer has not been installed yet (see: Fig. 2.4.5 -> 2).
Å Push the placement head which has been thus prepared (3 extended vacuum tubes) onto the
back portion on the gantry:
Screw the head tight (3 socket hex head cap screws M4).
Å Place the new Velcro-type fasteners (enclosed package from retrofit kit) onto the 3 narrow rib-
bon cables (see: Fig. 2.4.6).

2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) SIPLACE S-25 HM
2.4 Sequence: Installing the Hardware 02/01 Issue
60
.H\
1. Velcro-type fastener under the ribbon cables (3 cables "Stepped motors")
2. Velcro-type fastener on the bottom "Conversion board, small axis" (cable "Vacuum board")
NOTE:
When the modular head board is installed, the strain relief devices remain MOUNTED on the jack
connectors of the new cables (which are on the new head).
Å ONLY when the "Conversion board, small axis" is present:
Remove the strain relief bows from ALL jack connectors on the ribbon cables of the NEW
placement head.
The new cables are held on each of the connectors of the conversion board by 2 black terminal
strips on the left and right (see: Fig. 2.4.7 -> 5).
Å Pull the 2 wide ribbon cables off the dismantled placement head and connect them to the new
6-segment revolver head:
Take note of: This cable is different for the modular head board than for the "Conversion board,
small axis".
Å Lay the two wide ribbon cables as shown in Fig. 2.4.1.
Å Make the plug-in connections on the board and placement head.
Å Secure the cables with the ribbon cable clamp (see: Fig. 2.4.1).

SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen)
02/01 Issue 2.4 Sequence: Installing the Hardware
61
Å Pull the ribbon cable "Illumination" off the dismantled head and make the connection to the il-
lumination board and the new head. Take note of: This cable is different for the modular head
board than for the "Conversion board, small axis".
Å Make the connections of the 3 ribbon cables "Stepped motor" and the round cable "Revolver
head" (motor, tachometer) on the board.
Press the 3 ribbon cables with the 3 Velcro-type connections against the board holder.
Å ,QVWDOOWKHQHZUXEEHUPHWDOYLEUDWLRQGDPSHUVIURPWKHUHWURILWNLWRQWKHQHZKHDG
VHH)LJ!DVGHVFULEHGLQGHWDLOLQWKH&RQYHUVLRQ,QVWUXFWLRQV
DLM1 Col-
lect&Place Head", Item-No. 00191684-03.
CAUTION
If, instead of the rubber-metal vibration dampers, a metal bracket is still installed on the remaining
RV12-DLM1 head, the bracket must be replaced by the dampers (from a 2 enclosed package).
De-install the vacuum generator incl. silencer and proceed as described in the conversion instruc-
tions (see above).
Å Place the vacuum generator incl. silencer on the adapter plate and screw it tight (4 washers
A 4.3 und 4 socket hex head cap screws M4; size 3, in the enclosed package).
The enclosed package contains all fastening parts.
Å If applicable, remove the cover from the vacuum generator (2 socket hex head cap screws
M2.5; size 2).
Å Connect the ribbon cable "Vacuum board" to the conversion board / modular head board.
Secure it to the bottom of the board with the Velcro-type fastener (see: Fig. 2.4.7 -> 2).
For details -> see conversion instructions for the DLM1 head.
Å Fold down all black terminal strips (see: Fig. 2.4.7 -> 5).