00192328-01.pdf - 第69页
SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standa rd (Optionen) 02/01 Issue 2.4 Sequence: Ins talling the Hardware 67 Å Rem ove th e nozzle reje ct box and sc rew the nozzle chang er on …

2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) SIPLACE S-25 HM
2.4 Sequence: Installing the Hardware 02/01 Issue
66
Å Use the nozzle changer RV6 Standard from the retrofit kit (see Section 2.3.2).
Å Make the electrical and pneumatic connection on the bottom of the new nozzle changer as
shown below.
Å Fasten the interface cable of the nozzle changer and the compressed air hose to the back of
the new nozzle changer with a cable tie as shown above.
Å Place the new nozzle changer correctly into the fixed location pins of the carrier.
.H\
1. Reject box, removed
2. Screws fastening the nozzle changer RV6 Standard, RH side
Cable ties

SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen)
02/01 Issue 2.4 Sequence: Installing the Hardware
67
Å Remove the nozzle reject box and screw the nozzle changer on tight.
4 socket hex head cap screws M4 of different lengths, as follows:
– Back left -> M4 x 40
– Front left -> M4 x 50
– Back right -> M4 x 45
– Front right -> M4 x 10
.H\
1. Fiducials for position recognition
2. Reject box
NOTE:
In case of installing the RV6-DLM head during the upgrade S23 HM to SW V 502.xx, the bar from
the retrofit kit with the both fiducials for position recognition must always be mounted on the nozzle
changer RV12
, as described in the Retrofitting Instructions, Item no. 00192377-01
(position of the bar: see also in Fig. 2.4.8).
The fiducial marks are already on the new nozzle changer RV6.
Å Place the reject box from the nozzle changer back in.

2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) SIPLACE S-25 HM
2.4 Sequence: Installing the Hardware 02/01 Issue
68
Å Fasten the interface cable and the compressed air hose as shown above.
.H\
3. 2 Mounting pedestals, adhesive, with cable tie
4. Cable tie
DANGER
Do not use alcohol for any cleaning work near open flame!
Cable tie