SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standa rd (Optionen) 02/01 Issue 2.8 SITEST: Loading Nozzle Changer RV6 Standard with Nozzles and Calibrating 79 Å Se lect "Nozz le chang …

100%1 / 86
2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) SIPLACE S-25 HM
2.8 SITEST: Loading Nozzle Changer RV6 Standard with Nozzles and Calibrating 02/01 Issue
78
Å Double-click on the line in question as shown on the following screen or select "Edit" (button):
Å In the window that is opening, "Edit...", select the specified nozzle (e.g., type 920) that is con-
figured in the setup -> Select "Accept" (button).
Å Make this selection for each segment in succession.
Å In conclusion, select "Confirm exchange" (button).
SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen)
02/01 Issue 2.8 SITEST: Loading Nozzle Changer RV6 Standard with Nozzles and Calibrating
79
Å Select "Nozzle changer, head functions -> "Change configuration".
The following screen will appear:
NOTE:
The RV6 nozzle changer must be configured complete with nozzles.
- 900-series magazines must be defined with 900-series nozzle type (e.g., type 920),
- 800-series magazines with an 800-series nozzle type (e.g., type 820).
Å For each magazine, select the SPECIFIED nozzle (e.g., type 920 / 820) that was previously
defined on the head -> Select "Accept" (button) to accept this nozzle as the ACTUAL nozzle.
Å For each magazine, set the "Filling level" (button) to "0" -> Select "Accept" (button) -> Check
the filling levels.
Å If a RV6 head has already been installed on gantry 2, conduct the configuration process de-
scribed for gantry 2 (not necessary in the case of the 12-segment revolver head).
2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) SIPLACE S-25 HM
2.8 SITEST: Loading Nozzle Changer RV6 Standard with Nozzles and Calibrating 02/01 Issue
80
 &DOLEUDWLQJ1R]]OH&KDQJHU596WDQGDUG
5HTXLUHPHQW
Loaded with nozzles as described in Section 2.8.1.
Å To measure / calibrate the new nozzle changer, select
the ICON "Nozzle changer magazine functions" .
The following screeen for nozzle changer RV6 Standard will be displayed:
Å If necessary, check the magazine configuration with nozzles and the filling level "0" (buttons)
again -> see: Fig. 2.8.4.
Å In the field "Calibration", activate the function "ZLWKpickup height -> Select "All magazines"
(button):-> see: Fig. 2.8.4:
Å The calibration of the nozzle changer RV6 Standard follows.
First, the fiducials of the magazines and then the fiducials of the reject box are measured ->
Then the pick-up heights of the individual magazines are ascertained.