00192328-01.pdf - 第66页
2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) S IPLACE S-25 HM 2.4 Sequence: Inst alling the Hardware 02/01 Issue 64 'HLQVW DOOLQJWKH1R] ]OH&KDQJHU5 96W DQGDUG …
SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen)
02/01 Issue 2.4 Sequence: Installing the Hardware
63
Å Mount the cover on the vacuum generator (2 socket hex head cap screws M2.5;
size 2).
Å Mount the new head cover of the 6-segment revolver head from the retrofit kit.
Take note of:
The difference between the cover of the 6-segment head and 12-segment head is scarcely
visible. The item number of the 6-segment head cover is 00329003-01.
1R]]OH&KDQJHU596WDQGDUGIRU6HJPHQW+HDG
,QIRUPDWLRQDERXWWKH6HTXHQFH
– When installing the RV12 nozzle changer standard for the 12 segment revolver head, obey the
CAUTION text in Section 2.1!
– If the option MTC exists, you have to install the nozzle changer RV6 / RV12 MTC. In this case,
proceed for all steps on the basis of the "Retrofitting Instructions MTC on S-25 HM" (Item no.
see: Section 2.3.6).
– For removing the RV6 (or RV12) nozzle changer, proceed as described below.

2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) SIPLACE S-25 HM
2.4 Sequence: Installing the Hardware 02/01 Issue
64
'HLQVWDOOLQJWKH1R]]OH&KDQJHU596WDQGDUG
DANGER
Obey all safety instructions in Section 2.2.
The machine must be turned OFF and isolated from the mains, especially for all work in the vicinity
of the cutter. In addition, the compressed air feeder at the main valve of the compressed air unit
in the machine frame must be turned OFF and the compressed air lines bled by actuating the nee-
dle valve on the compressed air unit.
Never reach into the cutter from above or below. Even when the machine is OFF, you can still in-
jury yourself on the blades of the cutter.
Secure the machine conscientiously as described in the chapter "Locking the Machine..." in the
User Manual to prevent it from being turned back ON without authorization.
WARNING
While retrofitting, also make certain that the DANGER symbol and the DANGER text are placed
on the cover of the cutter (see: Section 2.3).
CAUTION
Make certain that now screws or other hardware fall into the cutter during the following de-instal-
lation / installation work.
Å On the bottom of the nozzle changer, loosen the electrical and pneumatic connections (see:
Fig. 2.4.8), incl. cable tie on the nozzle changer (see: Fig. 2.4.9).
Å Remove the 12-segment nozzle changer (RV12 Standard):
Undo the 2 socket hex head cap screws M4 above the spacer bolts (as shown in Fig. 2.4.8).
Lift out the nozzle changer.

SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen)
02/01 Issue 2.4 Sequence: Installing the Hardware
65
,QVWDOOLQJWKH1HZ1R]]OH&KDQJHU596WDQGDUG
.H\
1. Fastening screws for nozzle changer: 4 socket hex head cap screws M4
2. Electrical and compressed air connections on bottom of the nozzle changer
3. Nozzle changer for 12-segment revolver head, modular
4. Empty-tape duct (is not dismantled)
5. Carrier for empty-tape duct and nozzle changer, Item no. 00350480-01 (is not dismantled)
6. Bar with 2 fiducials (from retrofit kit), for nozzle changer; required for software version 502.01