2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) S IPLACE S-25 HM 2.8 SITEST: Loading Noz zle Changer RV 6 Standard w ith Nozzles and Calibrating 02/01 Issue 82 q
SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen)
02/01 Issue 2.8 SITEST: Loading Nozzle Changer RV6 Standard with Nozzles and Calibrating
81
Å In conclusion, check the pick-up heights ascertained for EACH magazine individually:
Select the magazines in succession by clicking on the relevant button -> Select "Display nozzle
data" each time.
Å For EACH magazine individually, check the ascertained values in the ODVWFROXPQ
– The max. permissible tolerance of all of the values of each magazine UHODWLYHWRHDFK
QHLJKERULQJPDJD]LQHis +/-10 digits.
– The values of the last column of a magazine must be in the range between 870 to 929 digits.
Å If the values are okay, select "Settings" -> Store machine data".
Å If there are deviations, check the following:
Å Is the mounting surface of the nozzle changer holder satisfactory/clean?
Å Was the nozzle changed correctly? Does the nozzle move sluggishly on the sleeve?
Å After eliminating the cause of the problem, repeat the determination of the pick-up heights,
including checking and storing the values, as described above.
Å Close the SITEST program and restart the machine.
Å Continue the work with "RV mapping".
590DSSLQJ
Å Carry out the"RV mapping" for the RV6-DLM1 head / for the pertinant gantry, as described in
the Software Guide SITEST V 502.xx.
3UHFLVLRQ&DOLEUDWLRQ
Å
Carry out the precision calibration as described in the Software Guide SITEST V 502.xx.
/LQH&RPSXWHU&RQILJXUDWLRQRI59+HDG1R]]OH&KDQJHU59
Å Configure the new placement head RV6 and the nozzle changer RV6 Standard (or MTC) in the
Station editor, as described in the Description of Software Version LRU 502.xx.
2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) SIPLACE S-25 HM
2.8 SITEST: Loading Nozzle Changer RV6 Standard with Nozzles and Calibrating 02/01 Issue
82
q