00192231-09_VD_SSW 407.05_de en.pdf - 第32页

Software Version Description, Station Software Version 407.05 07/2008 Edition SIPLACE S20 File Variable Description / Restriction KRAFT_12.MA Axis block 1: In addition, 1 active value ID: 19 All force levels: 6th value, …

100%1 / 208
Software Version Description, Station Software Version 407.05 07/2008 Edition
SIPLACE F5HM
File Variable Description / Restriction
KONFIG_L.MA Sensor system IDs/gantry group 0 Change to gantry group 1 (00723)
Coplanarity removed
KONFIG_R.MA Sensor system IDs/gantry group 0 Change to gantry group 1 (00723)
Coplanarity removed
PPW_STD.MA \ D-Sollposition \ jeweils 0 Nozzles wiped off at 0 degrees (00601)
SCANPA06.MA New parameter values (00614)
SCANPA12.MA New parameter values (00614)
TRANSP.MA Center conveyor coasting and PCB
timeout configurable (00604)
ref_lauf.ma Default entry for SpurleerMax (605)
scanpafc.ma New parameter values (00614)
31 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
SIPLACE S20
File Variable Description / Restriction
KRAFT_12.MA Axis block 1:
In addition, 1 active value ID: 19
All force levels: 6th value, old 2047, new 80
Force level 13 (higher than 8x noz.): 2nd value, old 80, new 40
Force level 13 (higher than 8x noz.): 3rd value, old 18, new 0
Force level 13 (higher than 8x noz.): 4th and 5th value, old 250,
new 150
Force level 13 (higher than 8x noz.): 6th value, old 2047, new
20
Changed values for pick-up with
nozzles in 8-nozzle heads
PPW_STD.MA \ D-Sollposition \ jeweils 0 Nozzles wiped off at 0 degrees
(00601)
REAL.MA Backlash times changed (00603)
SCANPA12.MA New parameter values (00614)
TRANSP.MA Center conveyor coasting and PCB
timeout configurable (00604)
ref_lauf.ma Default entry for adjustable retries
for the error: track empty (605)
SIPLACE S23
File Variable Description / Restriction
PPW_STD.MA \ D-Sollposition \ jeweils 0 Nozzles wiped off at 0 degrees
(00601)
REAL.MA Backlash times changed (00603)
SCANPA12.MA New parameter values (00614)
TRANSP.MA Center conveyor coasting and PCB
timeout configurable (00604)
ref_lauf.ma Default entry for adjustable retries
for the error: track empty (605)
32 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
5.8 New Functions in 407.01
Version 407.01 of the software is based on Version 406.01 and incorporates all the functions and bugfixes of
this version. Version 407.01 of the software also incorporates the following new features and changes:
Improved fiducial and ink spot recognition
Clusters without fiducials
Position recognition before ink spot recognition
Component level indicator function (option)
Feeder position recognition
Version check
New "multicolor" PCB camera for F5HM
88 mm tape feeder
Vacuum evaluation
Top / bottom PCB barcode
5.8.1 Improved Fiducial and Ink Spot Recognition
There are three additional views in the fiducial manipulator (Synthetic fiducial, Ink spot and Illumination). This
makes it possible to teach in synthetic fiducials and ink spots. A fiducial can either be taught as an ink spot,
a taught fiducial or a synthetic fiducial. It is only possible to change the type using New fiducial, thereby
deleting the fiducial content. Synthetic fiducials increase the stability of fiducial recognition. Geometry and
tolerance are entered for synthetic fiducials.
The new ink spots increase the reliability and above all the speed of ink spot measurement. The teach-in
procedure for ink spots uses a wizard. "Go" and "No Go" detection takes place at the same high speed. An
illumination dialog is provided for the new PCB camera.
The new fiducial process supports circles, squares, rhombuses, rectangles, hollow circles, hollow rectangles
and crosses. The double cross is not supported. This can only be used with the old fiducial procedure. Circle
and square fiducials are particularly well suited in terms of accuracy and speed. The cross is equivalent in
terms of accuracy, although its finer structures mean it takes longer. The rhombus can be used if structures
such as vias and pads which may interfere with the fiducial are in the vicinity. No practical experience is
currently available with the rhombus.
Important:
Although hollow circles and hollow rectangles are supported, we would not advise applying these
fiducials to new designs. This is because these geometries are less well suited to reliable evaluation and
do not result in an increase in accuracy.
In the context of teaching synthetic fiducials and ink spots the option "automatic positioning" is available
only for transport 1.
33 of 104