Software Version Description, Station Software Version 407.05 07/2008 Edition
6.10 Errors Corrected in Service Pack 2 of the 407.01 Software
Error report 123474
The output conveyor interface did not function as specified. With downstream transport modules it
sometimes happened that a printed circuit board continued to be transported from the output
conveyor although no release had been issued. The software has been adapted accordingly.
Error report 123859
Problems with the measurement of a QFP100 have been removed by FW 308 of the coplanarity
module.
Error report 123840
Correction of an error in data preparation for coplanarity measurement. When a number of
components were to be measured with coplanarity, errors occurred when the component moved
over the coplanarity module.
Error report 1-1EJ7P
If a triple feeder for 0201 components was placed on a SIPLACE F5HM (407.01 software, SP1),
only track 1 of the feeder was stepped forward to the pick-up position, although, when a component
was set up on track 2, the station moved to this position and attempted to pick up components. The
same error occurred when a component was set up on track 3 of the above feeder. The error has
been corrected in Service Pack 2.
Error report 17F-M
Individual balls of a BGA were displayed badly displaced on the ICOS screen. The error could occur
with BGAs that were larger than 32.5 mm and not completely covered with balls.
For fine calibration with the IC head, no values were displayed for the four angular groups for
machines with a 12-nozzle head.
Error report 123460
In the case of DLM1 heads, customers frequently complained of distorted raceways. The reasons
for this are the transition between the raceway and the Z-claw and incorrect zero point correction of
the Z-axis. In order to remove the problem for platform 1 machines as well, the solution was taken
from version 502.01 SP3.
Error report 1-2M5Z5
When the first PCB moved into the first SIPLACE machine after a lengthy waiting time (synchr. dual
conveyor), it sometimes happened that the input conveyor did not respond correctly to this PCB.
The problem has been analyzed and corrected.
Error report 1-1ZQA1
Problems when the PCB barcode was requested frequently. A timeout error often occurred when
the barcode was read.
50 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
6.11 Errors Corrected in Software 407.01 Servicepack 1
Error report 123755
Sporadic message (actionline) "Switch on compressed air":
This message appears as a result of modifications to the electric compressed air valve.
The software has been corrected accordingly.
Error report 123746
Diagnostics not installed (data similar to 406):
The data for version 407.01 is installed by the service pack.
Adaptation of the BDELR process as a result of sporadic crashes. This has meant that the line computer
could not be supplied with data for MaDaMaS. A further effect of this was a slowing of all the production
processes on the affected machine.
It is not possible to change language several times in SITEST tool in version 407.01. The cause of the
error has been eliminated. This means that the language can be changed in the usual manner.
Using the pf-File (20_5.gf) for the calibrating-part to the calibrate the PCB camera from the version 502.
The fine calibration for the 12-segment C&P head is carried out using ceramic pads.
6.12 Errors Corrected in Software 407.01
Error message "2278 IC: interval open - closed vacuum value too low" when using gripper nozzles.
Up to now, a change had to be carried out at the line computer in order to use gripper nozzles
(modification to the ".kd" file on the line computer). As of version 407, the gripper nozzle has been
implemented correctly in the MC software and the modification to the ".kd" file must be reversed (this
has already been done if an update to the line computer software version 502.xx has been carried out).
"2255 Axis error: Command DAIN, but bit set"
Corrected by modification to the axis driver.
Error report – ID 1999.10/EA1E/0089 (205)
Width adjustment error no longer requires Start button to be pressed. Instead, it switches directly to set-
up mode. Here it is possible to correct the error in the conveyor controller or using SITEST. The
procedure is terminated with the "Continue processing" button
It is no longer possible for the station to "hang" after SITEST is run as it was in Version 406.01.
Error report – ID 1999.11/EAEENG/0006 (140366)
Check the position of the axes in the event that a retracted sleeve is mounted.
51 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
Error report – ID 1999.09/EA1E/0029 (122157)
A reference point which was changed in SITEST is not re-read from achs_ver.ma if SITEST is exited
without saving.
When SITEST is exited, the machine data is now read in again (restored) and activated in the axes. This
means that the machine works with the required values as stored in the machine data. To ensure that
the data is transferred to the axis correctly, an additional reference run is carried out when SITEST is
exited.
Error report – ID 1999.08/EA1F/0076 ( 122124)
Error report – ID 1999.09/EAEENG/0006 (140331)
Error report – ID 1999.09/EA1F/0092 (122228)
A new TCP/IP library has been incorporated into the RMOS operating system and the MC application.
This ensures more stable communication within the machine.
Error report – ID 1999.11/EA1V/0023 (122387)
In version 405.02, an incorrect error message is issued during the check of the nozzle changer
configuration for the second gantry when a new job is being defined for a SIPLACE 80S23. The
message indicates that the nozzle changer configuration for gantry 1 is incorrect, although this gantry
has just been corrected.
The correct error message is now issued.
Error report – ID 1999.11/EA1V/0011 (122376)
As of Version 404, a new nozzle changer module was generated. The nozzle changer types were
redefined at this time. The type number for the 6-nozzle C&P head was changed from 3 to 6.
Error report – ID 1999.10/EA1V/0017 (122249)
On a SIPLACE S23 under Version 405.02, if an X/Y special sequence was entered at the line computer,
the following error situation occurred:
Component was removed from optical centering.
The component should have been rejected during error correction.
To do this, the gantry, however, incorrectly moves at maximum speed to the pick-up position of
the first feeder.
If an new component is now to be picked up at the segment with the faulty component, the
machine now (correctly) moves to the reject bin at reduced speed.
Components to be rejected were previously not taken into account when calculating speeds and
acceleration. The calculation has been corrected.
Error report – ID 1999.08/EA1F/0071 (122112)
Before the Teaching dialog box is displayed at the GUI, the second gantry moves to the wait position
after a prompt has been issued and the Start button has been pressed. The required position for the
PCB camera can then be taught.
52 of 104