Software Version Description, Station Software Version 407.05 07/2008 Edition The message "Action: Waiting till output conveyor empty" was not displayed after a fiducial had been taught (and saved). This error …
Software Version Description, Station Software Version 407.05 07/2008 Edition
• At installation of the SIPLACE F5HM, the integrated C&P head can be selected. Consequently, when the
machine is restarted, no error occurs during data preparation.
• The set-up positions of the machines have been moved by 70 mm. This permits free access to the
nozzle changers.
• The configuration of ceramic substrate centering for the "Multicolor" PCB camera in the SIPLACE F5HM
has been changed. It is no longer possible to select oblique illumination.
• The "Stop processing PCB" button no longer has to be used in fine calibration during the placement
process. The printed circuit board remains on the center conveyor automatically.
• Error report 1-YZ9D
Dip fluxing is possible with the IC head on the SIPLACE F
4
and the SIPLACE F5HM with the 12-nozzle
C&P head as of version 407.02.
Note: If components are set up that can be placed with either the 12-nozzle C&P head or the IC head, it
can happen that they are placed by the C&P head. These are then without additional solder paste. Dip
fluxing is still not supported for the 12-nozzle C&P head.
• Error report 123950
Following the installation of the station software, the A0110401.hex file (axis firmware version 4.001) is
located on the machine's station computer.
It can be copied to floppy disk from the "C:\SRProgramme\AchsFW\" directory.
1-3DP3M:
SIPLACE Pro interface: If a job was specified again with automatic width adjustment activated after
component package forms were taught, the conveyor width was measured again.
This is not necessary at this point, however, and is now no longer done.
1-3DYCT:
SIPLACE Pro interface: If a job was specified again after component package forms were taught, the job
for conveyor 1 was missing. This has been changed.
1-3CGHX:
SIPLACE Pro interface: If a job was specified again after the execution of the package form manipulator,
the preceding job was then processed rather than this job. The correct job is now processed.
• 1-2DM76
General problem when picking up heavy components in conjunction with 72x nozzles. The parameters in
the "Kraft.ma" file are modified for the 12-nozzle C&P heads of the SIPLACE S20 and SIPLACE F
4
( ).
This ensures that heavy components are also picked up and placed reliably.
• Error report 120454
When the PCB reference corners were taught, the C&P head position was displayed on the GUI rather
than the PCB camera position. The PCB reference corner position is now displayed correctly in SITEST.
• Error report 120714
47 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
The message "Action: Waiting till output conveyor empty" was not displayed after a fiducial had been
taught (and saved). This error occurred whenever the PCB could not move from the processing area to
the output conveyor (because the latter was occupied by another PCB). The station came to a standstill
without displaying a message indicating the error. The hourglass displayed on the monitor would not go
away, indicating an incomplete process. For this reason, the necessary status displays have been
permitted for the conveyor in set-up mode.
• Error report 120826
When there is a drop in pressure during placement, the SIPLACE machine comes to a standstill, and the
error message "No compressed air" is displayed. As soon as the compressed air returns, placement can
be resumed after the start button is pressed. The fitted printed circuit board was then occasionally
passed on to the next machine although components may have been missing. The software has been
modified so that the affected printed circuit board is now stopped on the output conveyor in the
processing area, allowing a check to be carried out (notification window).
• Error report 121770
If a nozzle was removed from the C&P head of a SIPLACE machine (except for an S15/F3) and then
picked up again immediately, a pick-up error occasionally occurred. The sleeve attempted to pick up a
nozzle from the 12- or 6-nozzle changer with the rotational axis turned by 90°. The error has been
corrected by a change to the "PPW_STD.MA" machine file.
• Error report 123103
In C&P mapping, the clamping was not released on conveyor 2 on completion of the mapping run. The
error has been corrected.
• Error report 123742
The container size was not scanned in by the barcode reader when the level monitoring option was set.
In order to correct this error, a change from version 502.01 has been adopted.
• Error report 123796
After the PCB camera was replaced, it could not be calibrated because incorrect calibration factors were
entered for bx and by. The calibration factors are now entered correctly when the PCB camera is
reconfigured.
• Error report 123813
When the height of the IC nozzle changer was calibrated, a superfluous height check was carried out.
This occasionally caused calibration to function incorrectly. The unnecessary height check has been
eliminated.
• Error report 123869
In the "Teach PCB camera" menu (gantry, PCB camera functions) in SITEST, the wrong illumination
was switched on (blue selected, but white switched on). This has been corrected.
• Error report 123901
Components were sometimes placed on the PCBs even when the PCB clamp was not working. No error
message appeared. The transport software now checks both Bero proximity switches when clamping a
PCB. As a result, this error is avoided.
48 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
• Error report 123390
In the vacuum test, the vacuum value measured was compared with the threshold "min. Vakuumwert
Segment zu" (minimum vacuum value with the segment closed) from the "Vakuum.ma" machine file. If
the closed value was under this threshold, the following error message appeared erroneously: "2277
The difference between open and closed vacuum values is too small." In version 407.02, the error
message "2455 Vacuum value of segment too low with valve closed" is issued.
• Error report 1-1MLCH
Incorrect parameter values in the "scanpara.ma" machine file. The values have been taken from the
technical information (ref. no. 10V05020).
• Error report 1-1IHCG and Error report DH-E
High pick-up error rate (around every 3rd head cycle for segment 7) when special sequences were
programmed for the gantries. It sometimes happened that the hand of the feeder had closed before the
component could be picked up. The timing of the sequences has been optimized. This prevents the
hand of the feeder from being retracted and closing again too early before the Z-axis can move down.
• Error report 1-2HH89
When the dip fluxing option was used, it occasionally happened that a component was not placed. This
error has been corrected in version 407.02.
• Error report 123965
In the default machine data of version 407.01, a "Ratio -IC- Sensor" camera is now entered as the
default for a SIPLACE F
4
instead of the old IC camera. This camera replaced the old standard camera
and was then used in all new machines. The old camera therefore has to be configured in SITEST after
a new installation or reinstallation of SIPLACE.
• Error report 120743
When the camera position was displayed (calibration of the IC head and camera in the "Calibrate entire
machine" menu), the current and old values were the same. The values are now displayed correctly.
• Error report 123953
If you install the 407.01 software on the station computer, you can also enter the addresses for the
SIPLACE LAN via the installation menu. You cannot change the machine's IP addresses in this dialog
box. The addresses entered must agree with NT or RMOS. If you want to change the IP addresses, call
the Siemens Hotline.