00192231-09_VD_SSW 407.05_de en.pdf - 第9页

Software Version Description, Station Software Version 407.05 07/2008 Edition operator = “1” comp=”0805” barcode1=”xxxxxxxxxxxxxxxxxxxxxxxx” barcode2=”xxxxxxxxxxxxxxxxxxxxxxxx” barcode3=”xxxxxxxxxxxxxxxxxxxxxxxx” contSiz…

100%1 / 208
Software Version Description, Station Software Version 407.05 07/2008 Edition
3 Interfaces
Data interfaces:
Interface SC/LC: Revision level 4.0
Interface SC/ SIPLACE Pro: Revision level 1
Interface to local machine data: Revision level 75
Commissioning tools:
SITEST: SI 407.04
Fine calibration:
Cmc_mess.exe Version 1.08
CmcStat.exe Version 1.3.1.0
Sikalib.dll Version 407.04
Kalib.dll Version 407.05
Traceability:
Traceability data, Versions 1.1 and 2.1 ,selectable
Traceability data, Version 2.1, only possible in conjunction with line computer SOKO "long BP".
Traceability data, Version 1.1 corresponds to the Traceability 407.02 specification.
Example of a Traceability file with Traceability data, Version 2.0
<?xml version = “1.0”?>
<TraceabilityData version=”2.0 line=”Line3” station=”Machine1”
job=”MyJob1” boardID=”TRX-6534” boardName=”MyBoard1”
dateBegin=“2000-12-22T10:43:09.37+0100“ dateComplete=“2000-12-22T10:43:29.12+0100“
errorLabel=”” setup=”HANDY4711”>
<charge id = “1”
operator = “1”
comp=”PLCC44”
barcode1=”xxxxxxxxxxxxxxxxxxxxxxxx”
barcode2=”xxxxxxxxxxxxxxxxxxxxxxxx”
barcode3=”xxxxxxxxxxxxxxxxxxxxxxxx”
contSize=”0”
packForm=”702”
tableID=”2”
loc=”3”
track =”13”
div=”1”
changed=”false” />
<charge id = “2”
8 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
operator = “1”
comp=”0805”
barcode1=”xxxxxxxxxxxxxxxxxxxxxxxx”
barcode2=”xxxxxxxxxxxxxxxxxxxxxxxx”
barcode3=”xxxxxxxxxxxxxxxxxxxxxxxx”
contSize=”0”
packForm=”105”
tableID=”1”
loc=”2”
track =”13”
div=”2”
changed=”false” />
<panel name=”panel2”>
<id ref = “1”>
<RefDes>Bpos_1</RefDes>
<RefDes>Bpos_3</RefDes>
<RefDes>Bpos_5</RefDes>
</id>
<id ref = “2”>
<RefDes>Bpos_7</RefDes>
<RefDes>Bpos_8</RefDes>
<RefDes>Bpos_9</RefDes>
</id>
</panel>
<spliceEvents loc=”2” track=”13” div=”2” count=”1” />
</TraceabilityData>
If no subpanel names are available, a subpanel with the name "undef" will be generated.
9 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
4 Requirements
The following operating system must be installed on the station computer to ensure that the station software
can be installed and will function correctly:
Windows NT 4.0 with Service Pack 6 and Microsoft Security Patch for Windows NT 4.0 (see
9.1.1) or
Windows XP with ServicePack 2
Attention:
Please make sure that only the Siemens XP Professional Service Pack 2 is installed. The
modified Siemens XP Professional Service Pack 2 is based on Mircrosoft Windows XP Service
Pack 2. Please make sure that never the Mircrosoft XP Professional Service Pack 2 is
installed.
No software or hardware products may be installed on the computer which are not compatible
with Windows XP SP2 (for details, refer to the relevant information from the vendor and to the
Microsoft website
http://support.microsoft.com/default.aspx?kbid=884130).
For details on the SIPLACE products, contact your SIPLACE representative.
If you encounter problems during installation or if the software does not operate correctly, please check
whether Service Pack 5 is installed. The installed Service Pack is indicated during the operating system boot
sequence.
For the troublefree functioning of the station software, it is prerequisite that the other machine components
be equipped with the following versions:
Station Computer
Version
SITEST
Version
Machine Controller
Version
Line Computer
Version
SIPLACE Pro
Version
407.05 407.05 407.05
502.01 1.1
(Standard)
503.01
for high components
and traceability
3.2 (Default)
as of 5.0*)
as of 5.2**)
*) when using forced setup verification
**) when using Splice sensors
The functional statuses of the station computer and machine controller software must be
compatible!
10 of 104