Software Version Description, Station Software Version 407.05 07/2008 Edition • The XML file is not generated in the traceability feat ure. The file is always in *.tmp. (FM 1-CO5U5) The system cannot convert *.tmp files …
Software Version Description, Station Software Version 407.05 07/2008 Edition
6.3 Errors Corrected in the 407.04 Servicepack 1 Software Patch C
• 1-BLJV9
The option for nozzle splitting has to be activated at first.
• 1-GITMI
If the C&P head is not occupied completely, the data of the xml file is not transmitted correctly. The error
has been corrected and the data is transmitted correctly.
• 1-COMI5
Problems with high components. The error has been corrected.
• 1-GYJ67
The component level indicator hangs up when upgrading. The component level indictor has been
reengineered.
• 1-GEMPS
Error 44 post vision
An error message is displayed, if no component is on the nozzle before placement.
6.4 Errors Corrected in the 407.04 Servicepack 1 Software
• The tracks cannot be sorted by the buffer time (FM 1- AEAM5)
The tracks cannot be sorted by the buffer time in the component level indicator. This error has been
corrected in this version.
• Tracks which fall below the threshold are not deactivated (FM 1-B8QOH)
When the operator opens the component level indicator menu, tracks which have fallen below the
threshold are not deactivated. The error has been corrected.
• Log manual entry of barcode (FM 1–BKNID)
Manual entry of the PCB barcode is now documented in a separate error code in the XML file.
• Suppress manual entry of the PCB barcode by a configuration mechanism (FM 1-BKNRF)
A configuration option has been added to the user interface for service engineers to disable manual
entry of the PCB barcode.
• Missing barcode verification: tracks deactivated even though the filling levels are displayed
correctly. (FM 1-BQY2X)
Tracks are not released (missing barcode verification: tracks deactivated) even though the filling levels
are displayed correctly. The error has been corrected.
• Operator ID is not written to the traceability file. (FM 1-CIYKH)
According to the version description, the operator ID must be written to the trace files. The error has
been corrected.
41 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
• The XML file is not generated in the traceability feature. The file is always in *.tmp. (FM 1-CO5U5)
The system cannot convert *.tmp files to XML. The XML file is not generated. The error has been
corrected.
• Fine calibration is not possible with Stations software 407.04 and IC head (FM 1-CTK0G)
The fiducials are not centered correctly with IC head. The fiducials are not recognized correctly and the
fine calibration aborts. The error has been corrected.
• The level indicator on the station computer causes a system crash. (FM 1-CN4F9)
The error has been corrected.
• SIPLACE Pro LC GUI is unable to connect to Station S20 (FM 1-DCHJC)
After new installation of Win XP SP2 and the stations software 407.04 there was no LC GUI connection
to Station S20. The error has been corrected.
• In barcode mode the component level indicator hangs up (FM 5LZ-2S9)
The error has been corrected.
6.5 Errors Corrected in the 407.04 Software
• Error report 1-47755
Occasionally, the message "Leak in segment after placement" was displayed for MC1 instead of MC2.
This meant that attempts to isolate the problem were made on the wrong hardware component. This
error has been corrected in this version.
• Error report 1-4JS09
If an error occurs when measuring components, several messages can be issued. This is necessary in
order to trace the cause of the error. These individual errors were previously also reported to OIS. This
caused the number of components consumed to be calculated incorrectly.
The report to OIS has been corrected.
• Error report 1-6LWNT
The touch screen is not installed automatically when the 407.02 station computer software is installed.
Windows NT 4.0 for the N300, P300 had previously been installed on the computer. The touch screen
driver then has to be installed manually from the CD. The installation routine has been adjusted.
• Error report 1-6YNDP
Error in measurement procedure for WPC fiducial recognition Measurement is carried out for every
board. The fiducials cannot be measured correctly (they are not recognized correctly or they are not
centered correctly). This causes the pickup position of the WPC to be incorrect and the correction
values have to be adjusted on the line computer. The measurement procedures have been reworked.
Pickup correction is now calculated correctly.
42 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
• Error report 1-7SEIY
Software error in the integrated SOKO "high components" on SIPLACE F5HM machines.
After high components have been placed on a board in conveyor 1 (asynchronous dual conveyor), the
gantry moves to the fiducial of the board in conveyor 2 while the star is turning and in the process
removes the high components that have already been placed. The procedure has been improved.
• Error report 1-84JSH
The fine calibration programs in version 407.02 contained an incorrect fiducial position. Furthermore,
720 / 920 nozzles were on the C&P12 heads while only the IC head was placing components.
The programs have been reworked
• Error report 1-7WXPW
If an S20 is upgraded from 407.02 SP1 to 407.03, the machine data converter aborts with the message
"not successful". The log file indicates that conversion was not successful for the following 5 files:
- Achs.ma
- Achs_std.ma
- Mappsteu.ma
- Kraft.ma
- Scanpara.ma
The converter was modified accordingly.
• Error report 1-8RN1H
When switching between various placement programs, the error message "2477 Unknown nozzle at
segment, none specified in configuration" was issued. The cause of this was that the currently measured
nozzle lengths were not initialized during the height reference run.
• Error report 1-8S0H9
Problems on picking up components from very deep pockets. The feeder is moves on before the nozzle
has left the component pocket. As a result, the nozzle is trapped in the feeder and the gantry axes start
to move. This damages the IC head. This error was eliminated by revising the cycle sequence.
• Error report 1-8S719
User interface crashes. Machine must be rebooted.
Problems representing the individual component levels occurred in the context of the component level
indicator. If the data was updated and at the same time the user clicked on the surrounding interface,
incorrect data accesses occurred and the interface crashed. It was possible to eliminate the cause of
this error.
• Error report 1-8VMHY
In the software version description version 4.01 is still stated as a requirement for SIPLACE S23 and
SIPLACE F5HM. This is not correct. Version 4.03 of the firmware should be read in.