00197787-02_SI_SIPLACE_HeadVerification_EN.pdf - 第20页

3 Head verification principles 3.3 Head verification software 20 Software Manual SIPLACE Head Verification 03/2018 3.3.4 Measurement progress After starting the head verification process, the software runs all measuremen…

100%1 / 90
3 Head verification principles
3.3 Head verification software
Software Manual SIPLACE Head Verification 03/2018 19
3.3.3 Starting the head verification
The Progress tab shows the previously selected measurements and the status of the individual
tests.
NOTICE
Previous settings still available
All previous settings are still available and can be changed any time before the head verific-
ation has been started.
Click the Previous button to return to the previous page.
Fig.20: Progress tab
Enable the Auto details check box(2) so that
the detailed test result is automatically displayed
whenever new measurement values are avail-
able.
Click the Start button(3) to start the head verific-
ation.
ð The status of the ongoing verification is dis-
played in the Status column(1). See 3.3.4
"Measurement progress" [}20].
ð When all tests are finished, the Summary tab
is displayed. See 3.3.6 "End of measurement
– Summary" [}22].
CAUTION
Loss of verification data
Clicking the Cancel button(4) aborts the whole test and looses all previous settings. The
verification process then needs to be started from the beginning.
Only click Cancel if you are sure to discard all results.
3 Head verification principles
3.3 Head verification software
20 Software Manual SIPLACE Head Verification 03/2018
3.3.4 Measurement progress
After starting the head verification process, the software runs all measurements consecutively. The
process is only interrupted whenever a user interaction is required or if an error occurs.
Fig.21: Measurement progress
The Status column(1) shows the verification status:
Gear = measurement in progress.
Green tick = measurement successful
Red cross = measurement failed
Click the arrow buttons(2) to navigate through in-
dividual measurements.
Click the red arrow buttons(3) to navigate
through the failed measurements. The buttons
are deactivated if no error occurred.
For more information, double-click a measuring
step(1), or select a step and click the Details…
button(4).
 NOTICE!
If the arrow keys are to be used, it is recommen-
ded to switch off the Auto detailsfunction. Oth-
erwise, the detailed information screen opens for
the currently running test whenever new data is
available.
.
Stop / Cancel buttons(5)
NOTICE
Stop aborts the current measurement
Clicking the Stop button interrupts the current measurement and unlocks the door. You can
only restart the measurement from the beginning, not from the point where it was interrup-
ted.
To restart the measurement, close the door and click Continue.
CAUTION
Cancel aborts the whole verification
Clicking the Cancel button aborts the whole test and looses all previous settings. The veri-
fication process then needs to be started from the beginning.
Only click Cancel if you are sure to discard all results.
3 Head verification principles
3.3 Head verification software
Software Manual SIPLACE Head Verification 03/2018 21
3.3.5 Test details
During the head verification you can investigate on the test details achieved.
Fig.22: Force LS (dynamic) test – Details view
1 Different graphs showing the measurement details for each segment:
The red lines indicate the limits shown in the header of the table below the graph.
The values for each segment are indicated by blue or green dots and lines.
2 Button to expand the graph for a more detailed view.
3 Table showing the measured segments, the defined limits, the individual data and the
achieved results.
4 Show overview button to return to the Progress view.
5 Arrow buttons to navigate through individual measurements.
6 Red arrow buttons to navigate through failed measurements.
7 Stop/Cancel buttons
NOTICE
Live image display
For measurements using the camera, a live image is displayed in the right corner of the
Progress tab.