6 Description of the test results 6.3 Air & vacuum with external sensor 40 Software Manual SIPLACE Head Verification 03/2018 6.3 Air & vacuum with external sensor 6.3.1 Measurement principle This measurement is u…

100%1 / 90
6 Description of the test results
6.2 Air & vacuum with head sensor
Software Manual SIPLACE Head Verification 03/2018 39
14 Result view indicating if the values are within (green tick) or outside (red cross) the limits.
15 Graph showing the Vacuumopen values for each segment.
16 Graph showing the Vacuumdelta values for each segment.
17 Graph showing the Holdingopen values for each segment.
18 Graph showing the Vacuumcalibpart values for each segment.
19 Graph showing the Air values for each segment.
6.2.3 Interpretation of the results obtained
‘Vacuum open’ / ‘Vacuum delta’ error for all segments
Cause Solution
Vacuum pump defective Maintain the vacuum pump or replace it.
Seal (four-hole rubber disk) for holding circuit
not fitted correctly or damaged
Check the seal position or replace it.
Holding circuit polluted Maintain or clean the holding circuit in an
ultrasound bath.
‘Vacuum open’ / ‘Vacuum delta’ error for individual segments
Cause Solution
Filter disks sealing damaged / poor air-tightness
at the nozzle seating
Replace the filter disks.
Nozzle worn or damaged Replace the nozzle.
Vacuum hose to the affected segment polluted
or damaged
Replace the vacuum hose.
Holding circuit polluted Maintain or clean the holding circuit in an
ultrasound bath.
‘Delta vac. 0-270°’ error for individual segments
Cause Solution
Segment (DP) defective or without planarity to
the nozzle contact surface
Replace the segment (DP).
Internal segment (DP) vacuum cycle defective Replace the segment (DP).
6 Description of the test results
6.3 Air & vacuum with external sensor
40 Software Manual SIPLACE Head Verification 03/2018
6.3 Air & vacuum with external sensor
6.3.1 Measurement principle
This measurement is used to determine the vacuum and air blast quality of the placement head
and its segments by an external sensor. Several tests are performed to verify the different aspects
of the vacuum system, and also to compare the achieved results with the results that are achieved
from the test with the internal sensor.
1. The vacuum is measured with the internal sensor and the segment closed, and then with the
segment open at the external sensor.
2. Finally, the air blast is activated and measured with the internal sensor, and then with the seg-
ment at the external sensor.
6.3.2 Measurement result
Fig.35: Result view – Air & vacuum with external sensor
1 Measured Segment
2 Values of the Air external measurement using the external sensor.
3 Values of the Air head measurement using the internal sensor.
4 Delta air shows the difference between Air external and Air head:
Delta air = Air head - Air external
5 Values of the Vacuum external measurement using the external sensor.
6 Values of the Vacuum head measurement using the internal sensor.
7 Delta vacuum shows the difference between Vacuum external and Vacuum head:
Delta vacuum = Vacuum head - Vacuum external
8 Vacuum zero shows the difference between Median
Vacuum external
and Vacuum external:
Vacuum zero = Median
Vacuum external
- Vacuum external
6 Description of the test results
6.3 Air & vacuum with external sensor
Software Manual SIPLACE Head Verification 03/2018 41
9 Zero deviation shows the difference between Median
Air external
and Air external:
Zero deviation = Median
Air external
- Air external
10 Result view indicating if the values are within (green tick) or outside (red cross) the limits.
11 Values of the Rev. voltage measurement show the reference voltage during the measure-
ment. Always check for a low reference voltage as otherwise this can limit the available
measurement range.
12 Graph showing the Air external (blue) and Air head (green) values for each segment.
13 Graph showing the Delta air values for each segment.
14 Graph showing the Vacuum external (blue) and Vacuum head (green) values for each
segment.
15 Graph showing the Delta vacuum values for each segment.
6.3.3 Interpretation of the results obtained
‘Vacuum head’ ok / ‘Vacuum external’ error for all segments
Cause Solution
External vacuum filter defective Check / exchange the external sensor.
‘Vacuum head’ ok / ‘Vacuum external’ error for individual segments
Cause Solution
Sealing damaged / poor air-tightness at the
nozzle seating
Replace the filter disks.
Nozzle worn or damaged Replace the nozzle.
Vacuum hose to the affected segment polluted
or damaged
Replace the vacuum hose.
Holding circuit polluted Maintain or clean the holding circuit in an
ultrasound bath.