00197787-02_SI_SIPLACE_HeadVerification_EN.pdf - 第24页

4 Offline head verification 4.2 Available measurements for C&P20A 24 Software Manual SIPLACE Head Verification 03/2018 4.2 Available measurements for C&P20A Required tools ● 1x endurance run unit [03086515-xx] …

100%1 / 90
4 Offline head verification
4.1 Preliminary steps
Software Manual SIPLACE Head Verification 03/2018 23
4 Offline head verification
4.1 Preliminary steps
NOTICE
Complete head required
A comprehensive C&Phead verification requires a component camera.
For the offline head verification, the HCS needs to be prepared in accordance with the head to be
verified. The table below provides an overview of the preparations required.
For more information, see the SIPLACE Head Care Station User Manual [00197262-04].
Task C&P20A C&P20P CPP P&P
(TH)
Install the "Stopper CP20-CPP”. x x x
Install the "Stopper P+P". --- --- --- x
Prepare the "Calibration tool pocket" for
"Calibration tool version SST23".
x x --- ---
Prepare the "Calibration tool pocket" for
"Calibration part version 3".
--- --- x ---
Connect the cable at the back to the "Ad-
apter-LP CPP/CP20-HCSII".
x x x ---
Connect the cable at the back to the "Board
Adapter-LP TWIN-HCSII".
--- --- --- x
Set the switch at the back. 40V 40V 150V ---
Mount the head equipped with nozzles. 1235 4235 2057 517
Connect the camera cables. 2x 2x 2x ---
Connect the flat ribbon cables. 2x 2x 2x 2x
Connect the compressed air / vacuum pump
supply.
2x 2x 2x 2x
Connect the exhaust hose. x x x x
Switch on the control box. x x x x
Switch on the head. x x x x
Start the Test Bench software. x x x x
Log in as “Machine Service”. x x x x
Check / adjust the zero point corrections. Z / Star Z / Star Z / Star D
Start the head verification. x x x x
Adjust the force sensor. x x x x
Open the main compressed air supply at the
back.
x x x x
Open the valves for the required compressed
air / vacuum supply.
x x x x
Check / adapt the meta data x x x x
4 Offline head verification
4.2 Available measurements for C&P20A
24 Software Manual SIPLACE Head Verification 03/2018
4.2 Available measurements for C&P20A
Required tools
1x endurance run unit [03086515-xx]
1x CP20 – CPP stopper [03095249-xx]
1x calibration tool pocket [03086419-xx]
1x nozzle centering unit [03086323-xx]
1x calibration jig version SST23 [03034148-xx]
20x Nozzle 1235 [03015222-xx]
1x vacuum measurement unit [03085726-xx]
20x Nozzle 1069 [03094112-xx]
1x force measurement unit [03086502-xx]
Verification workflow
Fig.24: Available measurements for C&P20A
1 Head info
2 Head statistic data
3 DP statistic data
4 eSW versions
5 Anti-glare shield mounting
See 6.4 "Anti-glare shield mounting" [}42]
6 Air & vacuum with head sensors
See 6.2 "Air & vacuum with head sensor" [}37]
7 Segment offset up (SOO)
See 6.21 "Segment offset up (SOO)" [}78]
8 DP rotation test
See 6.8 "DP rotation test" [}48]
9 Air & vacuum with external sensor
See 6.3 "Air & vacuum with external sensor" [}40]
10 CS Sensor voltage and z-heights
See 6.5 "CS Sensor voltage and z-heights" [}44]
11 Holding circuit (sealed nozzles)
See 6.17 "Holding circuit (sealed nozzles)" [}68]
12 Nozzle spring
See 6.18 "Nozzle spring" [}70]
13 Force LS (dynamic)
See 6.11 "Force measurement for C&P heads" [}54]
14 Force 01005 (dynamic)
See 6.11 "Force measurement for C&P heads" [}54]
15 Force 5N (dynamic)
See 6.11 "Force measurement for C&P heads" [}54]
16 Z axis movement
See 6.22 "Z-axis movement" [}81]
17 Head Endurance Run 01005
See 6.14 "Head endurance run 01005" [}60]
18 Head Endurance Run LS
See 6.16 "Head endurance run LS" [}65]
4 Offline head verification
4.3 Available measurements for C&P20P
Software Manual SIPLACE Head Verification 03/2018 25
4.3 Available measurements for C&P20P
Required Tools
1x endurance run unit [03086515-xx]
1x CP20 – CPP stopper [03095249-xx]
1x calibration tool pocket [03086419-xx]
20x nozzle 4235 [03015222-xx]
1x calibration jig version SST23 [03034148-xx]
20x nozzle 4069 [03106244-xx]
1x vacuum measurement unit [03085726-xx]
1x nozzle 4004 [03098544-xx]
1x force measurement unit [03086502-xx]
1x nozzle 4105 [03102457-xx]
Verification workflow
Fig.25: Available measurements for C&P20P
1 Head info
2 eSW versions
3 ZDS sensor values
4 Air & vacuum with head sensors
See 6.2 "Air & vacuum with head sensor" [}37]
5 Air & vacuum with external sensor
See 6.3 "Air & vacuum with external sensor" [}40]
6 Segment offset up (SOO)
See 6.21 "Segment offset up (SOO)" [}78]
7 DP rotation test
See 6.8 "DP rotation test" [}48]
8 Holding circuit (sealed nozzles)
See 6.17 "Holding circuit (sealed nozzles)" [}68]
9 CS Sensor voltage and z-heights
See 6.5 "CS Sensor voltage and z-heights" [}44]
10 Nozzle spring
See 6.18 "Nozzle spring" [}70]
11 Force LS (dynamic)
See 6.11 "Force measurement for C&P heads" [}54]
12 Force 3N (dynamic)
See 6.11 "Force measurement for C&P heads" [}54]
13 Force 4N (dynamic)
See 6.11 "Force measurement for C&P heads" [}54]
14 Force 5N (dynamic)
See 6.11 "Force measurement for C&P heads" [}54]
15 Z axis movement
See 6.22 "Z-axis movement" [}81]
16 Component sensor calibration
See 6.6 "Component sensor calibration" [}46]
18 Head Endurance Run LS
See 6.16 "Head endurance run LS" [}65]
19 Head endurance run “min force”