444CEMM1.pdf - 第130页
Page 1-68 444C-E-MMA01-A09-04 Check Every 560 Hours (Once a Month) 1-5-2 Cleaning and Lubricating the Cutting Unit For D/DU, the cutting unit is an option. The cutter consists of the fixed blade and movable blade. ∗ For …

Page 1-67
REGULAR
MAINTENANCE
1
444C-E-MMA01-A08-02
Check Every 560 Hours (Once a Month)
17. Raise the nozzle which has been
measured.
∗ Press
UNLOCK
+ for pos 1.
18. Turn OFF the vacuum for the nozzle
position which has been measured.
∗ Press
UNLOCK
+ for pos 1.
Measure the nozzle at other position.
(Here we describe position 2 as an example.)
19. Turn ON the nozzle position to be
measured.
∗ Press
UNLOCK
+ for pos 2.
20. Lower the nozzle at the position to be
measured.
∗ Press
UNLOCK
+ for pos 2.
After it, repeat steps 10 to 20, and check the vacuum pressure at all nozzle positions.
Vacuum
OFF
Vacuum
ON
Nzl Extend
ON
2
1
1
2
Nzl Extend
OFF

Page 1-68
444C-E-MMA01-A09-04
Check Every 560 Hours (Once a Month)
1-5-2 Cleaning and Lubricating the Cutting Unit
For D/DU, the cutting unit is an option. The cutter consists of the fixed blade and movable blade.
∗ For DU/DHU specifications, it is necessary to remove the feeder base cover for the maintenance.
“1-2-3 Setting and Removing the Feeder Base Cover (Only for DU/DHU Specifications)”
Procedures of CM201-D/DU and CM202-D/DU
1. Turn OFF the power.
∗ Lock the main switch. A worker should carry
the key. (DU/DHU only)
2. Open the cover at the lower right of
the machine rear side.
∗ Remove the screw with the Philips driver.
M60E
DO NOT TOUCH THE CUTTER BLADE WITH YOUR FINGERS.
The edge is so sharp that you may injure yourself.
CAUTION
Tools Philips driver, wrench, and cloth Required time 30 minutes
R
E
L
E
A
S
E
T
R
I
P
O
F
F
O
N
R
E
S
E
T
4U4C-AB00
AR
BR
444C-401P
To the next page
444C-457E

Page 1-69
REGULAR
MAINTENANCE
1
Check Every 560 Hours (Once a Month)
3. Discharge the air.
Close the main air valve.
Pull up the regulator knob, and turn it to the left
until it stops.
Make sure the exhaust sound disappears and
the gauge shows 0 MPa.
Lock the valve lever. A worker should carry the
key. (DU/DHU only)
4. Open the safety cover.
5. Draw the tape feeder table.
6. Remove the tape chute.
∗ Loosen the bolt set to the inner side.
To the next page
444C-E-MMA01-A09-03
Bolt
444C-464P
444C-465P
Tape chute
444C-425E
Valve
444C-402P
1
2
3
4
1
2
3